Parallel Volume Bundle Aerial Insulated Cable
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Products Introduction:
Parallel Volume Bundle Aerial Insulated Cable (Parallel Volume Bundle wire) is a product popularized and applied in the fifteenth scientific planning of the rural grid construction by the national electric power company. The scientific staff in our company borrowed the experience of applying the wiring harness from abroad, on the basis of which they successfully developed this product by improving and designing its technique and structure, filling the blankness of this product.
The reactance in low-voltage power-supplying circuit is composed of impedance, capacitive reactance, and inductance. Parallel Volume Bundle wire supplies power through three-phase and 4-wire, so as to minimize the imbalance of three-phase load and to reduce the neutral wire current, thereby reducing the resistance consumption. As a result of using the compact symmetrical split structure, the wire inductance lowers, and the dielectric constant between the lines is increased, electricity capacity increases and the reactance is significantly reduced so as to achieve the purpose of expanding the capacity and reducing the loss eventually.
As the wires are bundled as a volume, the tensile strength has been greatly increased than a single one, thus reducing the possibility of single-phase getting broken. When suffering tensile force such as wind pressure and frost, the insulation between parallels is not under pressure, thus enhancing the operational safety factor and distinctly improving the effects of preventing against thunder, electricity stealing and leakage. The fissility of the volume makes it easy for the interconnection between branches and convenient for transfiguration and combination. Marked by the zero wire, it is clear to identify the sequence of phase, thus mistakes can be prevented. The connection of the parallel volume bundle wire uses fewer poles, horizontal bars and porcelain materials, saving a lot of metals. As insulation can reduce the height of the poles and can not be influenced by such complex environments as trees and compounding, the wire can be laid along the walls, thoroughly without poles, thus lowering the project cost. In addition, compared with single wire, it makes the construction more convenient and is more labor-saving and time-saving, thereby reducing the construction expenses. Compared with the pattern of ordinary aerial naked wire, the parallel volume bundle wire is advantageous in that its operational cost is low and it has obvious long-term interests.
Characteristics of the products:
Relatively low circuit loss, with 5% - 10% loss.
Making constructions convenient, time-saving and labor-saving and fixing expenses lower.
Having great tensile strength when combined and highly safe to prevent filching and leakage of electricity.
Lowering the cost of project and reducing the need of poles, horizontal bars and porcelain materials and also reducing the height of poles.
Standards of the products:
GB12527-90 rated voltage and below 1 kv aerialcable insulation.
State Power Corporation of the Ministry of Agriculture, "parallel cluster aerialcable insulation optional technical conditions"
Product Categories classifications of the products
The sub-conductor materials: parallel cluster aerial cable insulation have Tongxin, Lvxin two. According to the materials of the conductor, Parallel Volume Bundle Aerial Insulated Cable has copper core and aluminum core.
By insulating material at: parallel cluster aerial cable insulation is weathering of PVC (PVC), weathering of polyethylene (PE), according to insulated materials, Parallel Volume Bundle Aerial Insulated Cable can be divided into PVC, PE, and XLPE.
Cross-linked polyethylene (XLPE) insulation of three.
By sub-type structure: the parallel cluster aerial cable insulation is square (BS1), Star (BS2) peace-(BS3) three. According to the structure, Parallel Volume Bundle Aerial Insulated Cable can be divided into BS1, BS2 and BS3.
Note: (1)Conductor: Copper or Aluminium (2) joint rib: PVC or PE or XLPE (3)Insulation: PVC or PE or XLPE
Specification:
TYPE | TITLE | CORES | CROSS-SECTIONAL AREA |
BS0 –JKV-0.6 BS0 –JKY-0.6/1 BS0 –JKYJ-0.6/1 | Copper core Parallel Bunched Aerial Insulated Cable with rated voltage 0.6/1kv |
4 |
2.5-70 |
BS0 –JKLV-0.6/1 BS0 –JKLY-0.6/1 BS0 –JKLYJ-0.6/1 | Aluminium core Parallel Bunched Aerial Insulated Cable with rated voltage 0.6/1kv | 4 4+1 | 4-25 35-120 |
BS0 –JKV-0.6 BS0 –JKY-0.6/1 BS0 –JKYJ-0.6/1 | Copper core Parallel Bunched Aerial Insulated Cable with rated voltage 0.6/1kv |
2 |
2.5-70 |
BS0 –JKLV-0.6 BS0 –JKLY-0.6/1 BS0 –JKLYJ-0.6/1 | Aluminium core Parallel Bunched Aerial Insulated Cable with rated voltage 0.6/1kv |
2 |
4-120 |
Main product performance ITEM UNIT REQUITEMENT OF PERFORMANCE PVC PE XLPE 1 Original capability: tensile strength: min Mpa 12.5 10.0 121.5 Elongation at break: min % 150 300 200 2 Air-oven aging test: temperature ℃ 80±2 100±2 135±3 Air-oven aging test: time h 168 240 168 tensile strength: min Mpa 12.5 -- -- tensile strength: change rate % ±20 -- +25 Elongation at break: min % 150 300 -- 3 Change rate at break % ±20 -- +25 low temperature elongation test: temperature ℃ -35 -- -- low temperature elongation test: Elongation at break % 20 -- --
NO.
- Q: My car's stock stereo is pretty low power, probably less than 20 watts. I would like to replace the power wires with better ones, if not for any real benefit to sound quality then simply to satisfy a personal whim. 8 gauge wires would be too I think for the small spaces. Anyway, would a good quality speaker wire work just a good as a power wire of the same gauge?
- I trust DJ. additionally you are able to try your subs with a volt meter. turn the meter to ohm mode and touch the finally leads to your subwoofer pos. and neg. (it incredibly is unhooked from the amp). this promises you a analyzing which could be a mild one million,2,4,6, or maybe 8. If the extensive style bounces around ANY, then your subs are broken. you are able to basically be working 4 ohm whilst your amp is one million ohm reliable or some thing. in line with threat try rewiring your subs too when you do the flexibility. The decrease your speaker ohm load, the greater watts you get out of your amp. warning**** do no longer go below the cautioned ohm load of you amp. it's going to capture fire or blow fuses once you're fortunate.
- Q: What is a PVC Power Cable and what is its application?
- PVC Power cable : Polyvinyl coated power cable. this kind of cable can be used in domestic appliance, machines and outdoors, it's quite durable.
- Q: im having probelms with the end piece that goes into the computer, and it needs to be replaced.
- In order to give you the exact source to purchase the cable, please re-post with the Compaq model number. In general, you can purchase a power cable at any of the following sources: (1) Compaq, of course, online -- but its prices will be higher. (2) A 'brick-and-mortar' store, like Fry's -- bring your existing cable, and they will match it, at a price that will probably be lower than Compaq's online price; and (3) OKorder -- which will probably have the lowest price, but you will have to be careful about security. Again, please re-post with additional facts. Hope this helps.
- Q: What type of plastic is a power cable made of? Thanks.?
- Power cable isn't made of plastic, it is copper or aluminum covered with PE, PVC, or PTFE plastic.
- Q: Just wondering if the eVGA GT 440 graphics/video card needs a power cable connect from the psu to it.I bought a PC pre-made from JB HI-FI and going to upgrade my graphics card. The one I have currently is the Radeon HD 4650 and it appears to have no cable connecting to it. There are however, some cables connecting to the motherboard near it.
- No, it doesn't need one, but it's also a crappy purchase. The Radeon 6670 costs about the same, doesn't require external power, and slaps the GT 440 silly.
- Q: I have my Clearwire modem but have lost the power cable. Does anyone know what I would look for in a replacement power cable.
- check the Clearwire URL .. Support tab
- Q: So I was trying to run wiring for a 220 outlet and I hit a lower leg with the metal cable snake, now a bunch of outlets loose power for a minute or two ever so often, 20 min give or take. What can be the cause? Only the top breaker tripped. How can this be repaired. Please help.
- You may have loosened a connection. With the breaker off, check all the outlets on the circuit that's losing power and make sure all the connections are tight.
- Q: I looked on 3 of my friends plus mine and looked at the cord that comes from the big block power supply thing for the xbox 360 and every one of them looked differant. Why is that?
- cause they felt like makeing them different
- Q: i'm having a power cable coming from the feeder pillar going to utility box that serving a yacht, i'm having few cut off in that cable what is the most good idea to repair it without replacing the cable and what is the material that used in that ?
- Have you got an anti surge socket to even out any voltage spike in line? I have and I've had several power cuts and my computer has never been affected. If not, then there is a possibility that you have blown the motherboard or the PSU. The reason this happens is your PSU drops the mains voltage from 240V to about 4.5V or less that your motherboard uses. Now when you get a power cut, when the switches in the power lines drop out, as the gap in the switch increases the voltage will jump as the current is trying to jump the gap. Thus for a few milliseconds the voltage in the mains can jump up to 20% which take it up to about 280V. Push that ratio all the way along and your motherboard voltage will jump to about 6V. Poof! Motherboard blown. Your only option is to put it into a workshop and find out exactly what damage you have done to it. You may be lucky as some manufacturers fit internal anti surge fuses.
- Q: W22 in the cable on behalf of what
- Is the name of the vv22 it is armored copper core PVC insulated power cable V is PVC, VV said PVC insulated PVC sheathed, insulation and sheath is two different things, the jacket is the outermost layer of the cable, Insulation, mainly from the role of protection cable, the insulation layer is wrapped in the conductor outside the layer, mainly from the insulation. 22 means armored, armored between the sheath layer and the insulation between the strip, and its role is to strengthen the protection of the cable, at the same time, can prevent the mouse bite, can also be used as ground. The copper core is not shown in the letter in the model, because most cables are copper, so the copper cable basically takes its representation (indicated by T). On the contrary, if it is aluminum core cable, it will be added in the model L said aluminum core.
Send your message to us
Parallel Volume Bundle Aerial Insulated Cable
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords