P-2 inch self priming Centrifugal Non-clogging sewage pump
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 120 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Welcome to lanco pump
P-2 inch self priming Centrifugal Non-clogging sewage pump
is our latest generation product base on US technology and craftwork. It is designed
for economical & trouble-free operation in handling solid-laden liquids and slurries.
Model P-2
1.Net weight 92kg |
2.Shipping weights 114kg |
3.Impeller dia. 158.75mm |
4.R.P.M. from 1150rpm to 2900 rpm |
5. Max solids 44.45mm |
Self-Priming
1. 650RPM 1.5m-750RPM 2.4m
2. 850RPM 4.9m-950RPM 5.8m
3. 1050RPM 6.7m-1150RPM 7.3m
4. 1250RPM 7.6m-1350RPM 7.6m
5. 1450RPM 7.6m-1550RPM 7.6m
6. 1650RPM 7.6m-1750RPM 7.6m
7. 1850RPM 7.6m-1950RPM 7.6m
Main charactor
1. beautiful shape and fine structure, reliable performance;
2. with strong capacity of self-priming, no need to equip with flap valve;
3. non-clog, and with powerful capacity of passing big solid;
4. The unique lubrication oil mechanical seal cavity makes the performance more reliable.
5. The hole can make sure that stronger sewage can be cleaned quickly when pump is jammed.
6. Special check valve structure can make the pump start quickly next time.
7. When operated, the pump can self-priming with gas and liquid at the same time.
8. Low rotary speed, reliable operation, long useful life, easily maintenance.
9. Advanced pressure protector make pump operate safety.
10. Very competitive price, high quality, small MOQ, fast delivery,OEM required,exporting plywood case.
Features
Solids Handling Impeller
Exclusive Abrasion-Resistant Seal
Removable Cover Plate with Easy-Grip Handle
Replaceable Wear plate
Removable Rotating Assembly
Application
1. Municipal Project, Sewage Project, Instruction Project;
2. Transportation of the sewage of uptown;
3. Sewage transportation in Hospital, hotel,slaughter house,fish breeding;
4. Classification of municipal sewage treatment factory and concentrate treatment systems engineering;
5. Transportation of the factory and contaminated water;
6. Sewage and deposit of water purifying system;
7. Industrial sewage of light industry,paper mill,textile,food processing plant,chemical industry,electric utility,deep mines,etc.;
8. Wine and sugar industry;
Operation condition
1. The temperature of medium no more than 80°C,the density of medium is 1.0~1.3*103Kg/m3,PH is within5~9.
2. Max diameter of solid should be less than76.2mm.
3. Max suction lifts no more than 3 inches or 7m.
4. Volume ratio of solids in the medium ≤2%.
5. Max.working pressure and suction head please refer to performance curve and table.
Performance
MODEL | R.P.M. R/MIN | FLOW m3/H | TOTAL HEAD m | MOTOR HP | NET WEIGHT kg | GROSS WEIGHT kg | MAX SOLIDS mm |
P-2 | 1150-2900 | 46 | 36 | 1 – 10 HP | 92 | 114 | 44.45 |
P-3 | 650-2150 | 107 | 35 | 1 – 20 HP | 183 | 205 | 63.5 |
P-4 | 650-1950 | 163 | 36 | 1 – 30 HP | 259.5 | 280 | 76.2 |
P-6 | 650-1550 | 330 | 33 | 2 – 40 HP | 364 | 391 | 76.2 |
P-8 | 650-1350 | 600 | 34 | 7.5 – 75 HP | 581 | 634 | 76.2 |
P-10 | 650-1450 | 775 | 40 | 10 – 100 HP | 635 | 663 | 76.2 |
P-12 | 650-1250 | 1275 | 42 | 20 – 125 HP | 998 | 1066 | 76.2 |
H-3 | 850-2150 | 85 | 62 | 1.5 – 25 HP | 214 | 225 | 20.63 |
H-4 | 850-2150 | 148 | 58 | 3 – 40 HP | 272 | 297 | 28.57 |
H-6 | 850-1950 | 308 | 57 | 5 – 75 HP | 413 | 437 | 31.75 |
- Q: How about the depreciation of vacuum pumps?
- (three) appliances, tools, furniture and so on related to the production and operation activities, for 5 years;(four) aircraft, trains, ships and other means of transport for 4 years;
- Q: The function of centrifugal pump
- 6. Stuffing box mainly consists of packing, water seal ring, stuffing box, packing gland and water seal pipe. The function of the stuffing box is mainly to close the gap between the pump shell and the pump shaft. The water in the pump is not allowed to flow outside and the outside air is not allowed to enter the pump. Always keep the vacuum in the pump! When the pump shaft and packing friction heat, it is necessary to rely on water seal to control water into the water ring, so that the filler cooling! Keep the pump running properly. Therefore, in the water pump running inspection process, the stuffing box inspection is to pay special attention to! In the operation of about 600 hours, it is necessary to replace the packing.
- Q: What are the causes of pump shock?
- 3. the water pump set screws loose, adjust the concentric, fastening the foot4. pump into foreign body, open cover overhaul5. the flow is too large or too small, adjust the equipment to control the water output
- Q: What is the principle of a turbopump?
- Turbine [turbine] is a machine that converts the energy contained in a fluid medium into mechanical work, also called a turbine. Turbine is the transliteration of English turbine, derived from the Latin word "turbo", meaning "rotating object".
- Q: How to install, operate and maintain the pipeline booster pump?
- Should be "People's Republic of China network security law" requirements, since June 1, 2017, the use of Internet services to carry out real name authentication account. In order to ensure your Baidu account can be used normally, please check the account number as soon as possible. Thank you for your understanding and support.How to install, operate and maintain the pipeline booster pump?Brother Yao s Gc76 2547 | browseRecommended for 2016-12-01 23:52:54 best answerThe installation of booster pump must be installed horizontally or vertically according to the installation method. The direction of flow shall be consistent with the arrow on the pump body, and installed as far away from the water level as possible. A valve shall be installed on the pump inlet line for ease of use and maintenance. When the impeller is the aspiration level below the pump on the pump shaft end or around the pump should be installed check valve, the outlet is connected with 13 links for water use, at first use to pump should be filled with water, and tighten the screw plug. The pipe connection should be tight, especially the water inlet pipe can not leak, otherwise it will reduce the pump head or not pumping water. The pump cavity is not water, not a long time running, so as not to damage the seal
- Q: Does the reservoir water heater press the booster pump (high marks)?
- The outlet water pressure of hot water is the same as that of cold water. The water heater is pushed by cold water to push out the hot water. (of heating). Installation location about 2 meters away from the ground, the impact of water pressure is not large, in rural areas, the installation position in more than two buildings will have an impact. In the city, the installation position is above four floor to affect the water pressure.
- Q: Water pump does not produce water, what are the reasons?
- 1 check whether the motor is reversed.2, to see whether the export, the entrance blocked, the outlet pressure gauge whether there is pressure.3, whether the pump selection is wrong, you can not suck up the water.
- Q: Why does the centrifugal pump start and close first when the outlet valve is closed?
- The contact is burned out, the bond and so on the accident, therefore closes the outlet valve, starts the electric machinery, at this time the electric machinery belongs to the no-load current movement, greatly reduces the big current impact
- Q: What are the main performance parameters of hydraulic pumps?
- speedOperating speed is the actual rotation speed of a pump (or motor) at work.Rated speed is the maximum speed that can operate normally for a long time under rated pressure. If the pump exceeds the rated speed, the work will cause insufficient oil absorption, vibration and noise, the parts will suffer cavitation damage, life expectancy.Minimum steady speed is the minimum speed allowed for normal motor operation. At this speed, the motor does not appear crawling phenomenon.
- Q: No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same, how to choose the control cabinet?
- Non negative pressure water supply equipment can be divided into non negative pressure tank and box type non negative pressure compensation device, steady flow tank type non negative pressure water supply equipment is the negative pressure tank, pressure tank can eliminate the negative effect of network equipment, is equipped with a vacuum suppressor and water protection box; non negative pressure water supply equipment has the advantages of simple device is a water tank with the boost voltage stabilizing device of complex box at the same time with no negative pressure tank.The tank type non negative pressure water supply equipment adopts vertical multistage centrifugal pump. This kind of pump is low noise and high efficiency. Such as CDL series and imported CR seriesOrdinary box type non negative pressure water supply equipment can use multi-stage centrifugal pump, also can use stainless steel submersible pump, submersible pump costs will be lower, but the maintenance costs will be high.
Send your message to us
P-2 inch self priming Centrifugal Non-clogging sewage pump
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 120 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords