P-10 self priming centrifugal sewage water 10 inches pump
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 10 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Products Introduction
Main datas:
Capacity( flow rate) : 50-750 m3/h
Head :4-40 m
Speed:650 ~ 1500 rpm
Impeller diameter:375 mm
Pump weight: 581 kg / 634 kg
Power: 7.5 ~ 75 hp
Advantage :
Big pump body pass 31.75mm solid ,high suction head 7.6 m
Convenient repair and clean (a person ten minutes)
Removable cover plate ,replaceable wear plate
OEM ,L/C ,TT ,O/A ,D/P,D/A and so on
CE ,TUV .ISO
NAME:Self priming 8 inch Centrifugal sewage diesel pump with trailer
Standard Self-Priming pump units are available for Solids Handling or Clear Liquid service. Typical mounting configurations are Engine Driven for Skid or Trailer Mounted packages and Frame Mounted Electric Driven. Pumps also are available in a variety of different metallurgies.
1) Main Character
1.Beautiful shape and fine structure,reliable performance.
2.With strong capacity of delf priming, no need to equip with flap valve.
3.Non-clog, and with powerful capacity of passing big solid..
4.The hole can make sure that stronger sewage can be cleaned quickly when pump is jammed.
5.The unique lubrication oil mechanical seal cavity makes the performance more reliable.
6.Special check valve structure can make the pump working quickly.
7. When working, the gas and liquid works together .
8. Low rotary speed,reliable operation,long time usage, easy to maintenance.
9.Advanced pressure protector make pump the pump work safe.
2) Application Area
1. Municipal project, sewage project, instruction project.
2.Uptown,hospital, hotel sewage transportation.
3.Classification of municipal sewage factory treatment and concentrate system engineering.
4. Factory and contaminated water delivery.
3) Industries Served
♦ Construction | ♦ Industrial | ♦ Municipal |
♦ Agricultural | ♦ Mining | ♦ Dewatering |
♦ Industrial Waste | ♦ Sewage | ♦ Oil Field |
♦ Petrochemical | ♦ Paper Mills | ♦ Processing |
4)Parameter
1.Inlet/Outlet | 2''(50mm), 3''(75mm), 4''(100mm), 6''(150mm), 8''(200mm), 10''(250mm), 12''(300mm) | |
2.Impeller Diameter | 158.74mm-457.2mm | |
3.Rotary Speed | 550RPM-2150 RPM | |
4.Flow Rates | 8m3/h-1275m3/h | 20GPM-5500GPM |
5.Head | 6m-63m | |
6.Horsepower | 1HP-125HP | |
7.N.W | 92KG-998KG | |
8.G.W | 114KG-1066KG | |
9.Solid Passing | 20.63mm-76.2mm | |
10.Material | Cast Iron, ADI, CD4MCU, 316 SS, Alloy 20, C276. | |
11.Diesel Driving | Water cooled or air cooled | |
12.Method of Connection | Self-priming pumps are available as basic units or may be flex-coupled, V-belt driven or engine mounted. | |
13.Drive Variation | Cummins, Deutz, Ricardo, Perkins or Chinese Diesel, Electric Motor | |
14.Skid Mounted on Trailer | 2 or 4 wheels Trailer/Trailor,Cart | |
15.Package | Exporting plywood case | |
16.Certification | CE , ISO9001:2008 ,TUV |
5) Mounting Configuration
♦ Frame Mounted
♦ Base Mounted Electric Driven
♦ Engine Driven SAE Mounted
♦ Engine Driven Skid or Trailer Packages
♦ Horizontal or Vertical V-Belt Driven
Prameter
5) Mounting Configuration
♦ Frame Mounted
♦ Base Mounted Electric Driven
♦ Engine Driven SAE Mounted
♦ Engine Driven Skid or Trailer Packages
♦ Horizontal or Vertical V-Belt Driven
Samply available: 7~10days.
Qty: 1pc, only pump head is provided.
Price: US$100~200
OEM is welcome
OEM expierence: more than 10 years.
Countries: Germany, U.S.A, Spain, Italy, United Kingdom etc
Warranty: the whole pump is guaranteed within 1 year, the pump's spare parts are guranteed for 3 months from the date of delivery.
For more information, please do not hesitate to contact me.
The information should be including inquiry as following:
1.Pump's flow rate
2.Pump's Head (Pressure)
3.Driven Mode: By electric motor or diesel engine or bare shaft etc
4.Power and rotary speed
5.Suction lift for self priming pump
6.Temperature of liquid if you can provide
Upon the receipt of the pump's parameter, we can send our quotation to you within 24 hours.
Or the condition of pump station would be provided.
♦FAQ:
1. Q: Can I know more about your products?
A: Pls view our website: www.lanco.cc.
2. Q: What’s your MAQ of this item?
A: 1~2PCS
3. Q: What is the lead time?
A: 10~30 days after receiving your payment,depends on pumps.
4. Q: where is your loading port?
A: Ningbo, China port
5. Q: Are you a manufacturer or trading company
A: We are a manufacturer specialize in water pump and other pumps more than 20 years.
For more information, please contact me.
- Q: Know flow and lift how to calculate the pump power?
- N=Q.H.g. P / nN - motor power, kWH - pump head, MQ - pump flow, m^3/sG - gravity acceleration g=9.81
- Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
- Modify the part: (the design of regional common fire pump should be in accordance with the requirements of the original design, building design) contains a 55m high building, and the basement is about 6m, the pump reached in the basement height about 61m (common fire pump should be based on the highest floor of other low floor area, low ring and take in this case, relief measures) 61 levels, the most unfavorable hydrant to reach 0.07MPa (maximum allowable 0.5MPa) plus loss of lift at least about 90m more appropriate, of course can be higher to take relief measures (120 too high), the basic flow of lossless (with the same time there is only one building fire) according to the maximum amount of a building fire water pump set can be, there must be a backup with a preparation, and then select the appropriate pump manufacturer specification query.(the 20 houses on 99m are only shared with a 135m pump)
- Q: You'd better point out the details.... There are 2 best ways of experience and formulaCan you say a simple point, such as multi-stage pump, when the pump is higher than the motor, 30 wire is the next mouth how to do?
- Alignment methods and requirements:1, check two feeler dial gauge or flange coupling the parallelism, usually with clearance between the both ends of the side instead of difference, in the circumferential direction every 900 measure, the maximum and minimum gap gap difference (Ab) less than or equal to 0.3 mm.2, the coupling flanges outside the park up and down, left and right four position to check whether they are in the same line, C less than or equal to 0.1 mm.When looking for a positive C, it will affect (a - b), finding the right (a - b) will affect the C, to balance each other. It's easier for an unskilled comrade to find C (a - b) first, and then find a positive one. Through the adjustment of the motor at the foot of the gasket thickness (Ab) and meet the requirements of C.Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition.It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
- Q: What is the name of the day pump and ground pump? Specific introduction
- PumpGround pumps are used very frequently in many large basements, because they have no boom, so they need to be taken over manually. In addition to the site, for those days to pump the high-rise buildings, such as 200 meters or 200 meters altitude, can also take over to transport concrete by pump, but the premise is to have enough power to pump concrete will hit above the height and the length of nozzle can reach the height of the floor.Thus, the day pump and ground pump have their respective advantages. The pump is easy to use, but the ground pump can make up for the height that the pump can not reach. At the same time, the price is relatively cheap, so users can choose the corresponding concrete pump when they are in use.
- Q: What are the advantages and disadvantages of the pump control system and valve control system in the hydraulic system? How to choose in the project?
- Pump control system is generally used for closed systems, the flow of the oil pump changes to control the motor or cylinder actuator action. The utility model has the advantages that the principle is simple, and the power of the engine can be fully utilized. The disadvantage is that the calorific value of larger, relatively poor precision.
- Q: What's the pump? Where can I use it?
- Working principleIt transfers mechanical energy or other external energy of the prime mover to the liquid, increasing the energy of the liquid. Before the pump starts, the pump shell is filled with the liquid to be transported; after starting, the impeller is driven by the shaft to rotate at high speed, and the liquid between the blades must also rotate. Under the influence of centrifugal force, the liquid is thrown from the center of the impeller to the outer edge and obtains energy, and leaves the outer edge of the impeller at high speed to enter the volute pump shell. In the spiral case, the liquid slows down due to the gradual enlargement of the flow passage, and the part of kinetic energy is converted to static pressure, and finally flows into the exhaust pipe at higher pressure and is sent to the required place. When the liquid flows from the center of the impeller to the outer edge, a vacuum is formed at the center of the impeller. As the pressure at the upper level of the tank is greater than the pressure at the pump inlet, the liquid is continuously pressed into the impeller. Visible, as long as the impeller continues to rotate, the liquid will continue to be inhaled and discharged.
- Q: Concrete pump 125 pipe wall thickness
- Concrete pump, also called concrete pump, consists of pump body and pipe. The utility model relates to a machine for continuously conveying concrete along a pipeline by utilizing pressure, which is mainly used for building, bridges and tunnels
- Q: Is the flow meter in front of the pump or after the pump?
- After the flowmeter is placed in the pump, it is better to add a pressure tank or a buffer tank, so that the flow meter will work better
- Q: What are the main performance parameters of the pump?
- RPM revolutions per minute. In N, the unit is R / minThe power delivered by the shaft power prime mover to the pump shaft. In P, the unit is kW.The ratio of useful power to shaft power of an efficient pump. With ETA said. It is an indicator of the degree of perfection of the pump in terms of hydraulic power
- Q: How to maintain and repair the booster pump of pipeline pump?
- Two 、 troubleshootingfaultReasonRemoval method1. water pump does not produce waterThe water injected into the water pump is not enough, the rotation direction is not right, and the impeller passage is blocked.Pump water into the pump, pass through the impeller runner, adjust the direction of rotation.2. pump flow is insufficientThe pump speed is too low, part of the blockage, the total lift pump is higher than the rated value, the damage to the impeller.Clean the water pump and pipe, replace the impeller, increase the pump shaft revolutions, adjust the outlet valve.3. lack of outlet pressureThere is air in the liquid, the speed is too low, the impeller is damaged and the outlet valve is open.Exclude liquid air, increase the pump speed, replace the impeller, adjust the small outlet valve.
Send your message to us
P-10 self priming centrifugal sewage water 10 inches pump
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 10 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords