• Self-Priming Centrifugal Water Pump for Irrigation System 1
  • Self-Priming Centrifugal Water Pump for Irrigation System 2
  • Self-Priming Centrifugal Water Pump for Irrigation System 3
Self-Priming Centrifugal Water Pump for Irrigation

Self-Priming Centrifugal Water Pump for Irrigation

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 Centrifugal Water Pump for Agriculture Application

1.Structure of  Centrifugal Water Pump Description

 

Centrifugal Water Pump is used for transporting pure water or liquids with physical and chemical  properties similar to pure water, and the maximum of the medium temperature is 80°C.(type ISR pump reaches 120°C). Widely applied towater supply industry, urban water supply and drainage, metallurgy, power stations, textile, chemical industry, printing and dyeing, ceramics, rubber, heating, waste heat utilization, air conditioning, agricultural irrigation and etc.

 

2.Main Features of the Centrifugal Water Pump

• Compact structure, good appearance, low construction

Operation stably, same inlet and outlet

•Convenient installation and maintenance

Customized design is available, OEM and ODM are welcomed.

•Horizontally and vertically installation as different pipeline system

3. Centrifugal Water Pump images

Self-Priming Centrifugal Water Pump for Irrigation

4. Centrifugal Water Pump Specification

 

Item

Diesel Water Pump

Diesel Pump

Agricultural Irrigation Desel Water Pump

Model

IS

Material

Cast iron

Mode

Horizontal

Color

Blue and adjustable

Theory

Centrifugal Pump

Structure

Single-stage Pump

Usage

water

Power

Electric

Standard or Nonstandard

Standard

Fuel

Diesel

Pressure

High Pressure

Application

Transporting pure water or liquids

Outlet Diameter

32-250mm

Capacity

6.3-400m3/h

Head

5-125m

Rotation Speed

1450-2900r/min

Power

0.55-110kW

Warrenty

1 Year

Certificate

ISO9001

Feature

High efficiency,Easy maintenance 

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

 

Q: If the suction pump does not have enough suction range, you need to add a vacuum pump to increase the suction stroke. How do you install the suction pipe of the vacuum pump? Water pump impeller is not closed, it is normal that the vacuum pump is unable to pump suction pipe to a vacuum, is it because the water pump outlet pipe connected to the role of the check valve? But the water pump, outlet pipe, check valve sealing performance can achieve the function of non leakage?
The role of the check valve:"[the water pump impeller is not closed" refers to the pump suction pump before the water without water inlet pipe and water outlet pipe gas should be connected] is a connector, a connector, still can make the level surface, in order to prevent the water flow along the pipe, until it reaches the level of the flush, then increased check valve, or pumping up water will not leak?Vacuum suction principle of self suction pump:Assuming that the pump connected with the water inlet of a sealed container, the container has plenty of water, since the start of a water pump, water is thrown out of the water impeller pump body, water inlet seal vessel due to the extraction of water to form a vacuum cavity, this assumption will be connected to vacuum cavity and exposed to atmospheric conditions of water, water at atmospheric pressure under the effect of entry into the vacuum chamber".....
Q: How many millimeters is the diameter of the water outlet of the four inch pump?
If it is a centrifugal pump, the nominal diameter of the outlet is less than 4 inches, there is a conical short tube to enlarge the standard 4 inch outlet flange, from here, is the standard 4 inch flange connection.
Q: What does "anti pump" mean in pump operation?
Function: anti pump effect when used for pumping concrete pumping occurs overpressure, the pumping pressure is above 25MPA, the concrete conveying pipe out of ash, can be understood as the precursor of pipe blockage, at this time should immediately use the anti pump, the concrete from the conveying pipe in the suction into the hopper, thus preventing plugging happen
Q: What does "efficiency" mean in a water pump catalog?
Pump efficiency: the ratio of the effective power and the pump shaft power
Q: What's the meaning of the pump head in the water pump, please advise, thank you
According to China Wikipedia network, the basic components of the water pump: motor, coupling, pump head (body) and chassis (horizontal).Pump is generally composed of pump body and pump head, in which the pump body refers to the spiral case, impeller, bearing, oil shell and sealing assembly, etc., the pump head refers to the impeller, bearings, oil ring and sealing rotating parts (including shaft), etc..
Q: Difference between pump and compressor
In the spiral case, the liquid slows down due to the gradual enlargement of the flow passage, and the part of kinetic energy is converted to static pressure, and finally flows into the exhaust pipe at higher pressure and is sent to the required place. When the liquid flows from the center of the impeller to the outer edge, a vacuum is formed at the center of the impeller. As the pressure at the upper level of the tank is greater than the pressure at the pump inlet, the liquid is continuously pressed into the impeller. Visible, as long as the impeller continues to rotate, the liquid will continue to be inhaled and discharged.The working principle of the linear pump is different from that of any other pump. It adopts the principle of magnetic suspension and the hydraulic structure of the spiral ring to realize liquid propulsion, that is, to cancel the shaft, to cancel the shaft connection, and to cancel the sealing structure of the shaft. After starting, the electric current is transformed into a magnetic field, and the magnetic field force drives the spiral ring to move, namely, the spiral ring promotes the liquid advance.Compressor (compressor), a driven fluid machine that promotes low-pressure gas as a high pressure gas, is the heart of a refrigeration system. It is of low temperature and low pressure refrigerant gas suction pipe from the suction, through the operation of the motor drives the piston to compress it after high temperature and high pressure refrigerant gas discharge pipe to the exhaust, to provide power for the refrigeration cycle, so as to realize the compression and condensation (exothermic), expansion and evaporation (endothermic) refrigeration cycle.
Q: Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
Four) release bolus dosage method can use automatic release and manual release two ways, the key is to alarm after the infusion must be stopped(five) any kind of pill dose release are not restricted to replace the pill. The total dose limit for in pipe blockage after pill agglomeration process will remove blocking accident, this time will be the rapid infusion of pill dose concentration into the patient's blood, if the total dose pill does not get test and limit, rapid infusion of this accident it may have unimaginable consequences.(six) supplies open type infusion pump overflow on the domestic market for pill characteristic parameters of consumables simply without testing and limitation. Therefore, the risk of accidental pill has become one of the residual risk of open type infusion pump supplies the most deadly.
Q: Common failure treatment of piston pump
Table 15 common troubles and treatment of hydraulic pumpsFault phenomenon, x09 cause analysis, x09 elimination method(1) the pump does not carry oil; the x091. pump does not turn x09 (1); the motor shaft does not rotate1) missed connection power supply2) electrical wiring and component failure, x09 check electrical and troubleshootx09x09 (2) motor heating trip
Q: When the water pump is started, why should it start when the outlet valve is closed? Thank you
And the pump at the start, if the valve opening pump, then the pump outlet pressure (head) is very small, so the pump flow will be great, the pump power is very large, causing the start-up current is very large. In addition, the starting current of the motor itself is also very large. These two factors add up to the possibility of overloading the motor, resulting in failure to start or even burn the motor.
Q: What is the difference between an air pump and a water pump?
Pump performance of technical parameters are flow, suction, lift, shaft power, water power, efficiency, etc.; according to the different principles of work can be divided into volume pumps, vane pumps and other types. Displacement pump is to use its studio volume changes to transfer energy; vane pump is to use the rotating blade and water interaction to transfer energy, there are centrifugal pumps, axial flow pumps and mixed flow pumps and other types.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords