Vertical Multistage Centrifugal Pumps with High quality
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 500 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
FEATURES:
Vertical Multistage grundfos water Pump is the latest model with the features of energy-saving and less space demand, easy to install and has stable performances.
1. With its 304 stainless steel shell and wear-resistant axle seal, there is no leakage and it can live long service life.
2. With hydraulic equilibrium to balance the axial force, the pump can run more smoothly, less noise, which can be easily installed in same level pipelines, enjoying better installation conditions than DL model.
3. With these features, GDL Pump can easily meet the needs and requirements for water supply and drain foe high building, deep well and firefighting equipments.
Flow range: 1.4-1 94.4CBM/h
Head range: 20-230m
Speed: 2900r/min
Maximal pressure of system: 2.5MPa
Medium temperature: -15~°C+120°C
Environment temperature: ≤+40°C
Motor protection level: IP44, IP54
Insulation grade: B, F rank
Rotation direction: Clockwise
APPLICATIONS:
Domestic water supply for buildings
Fire water supply for buildings
Water supply equipments
Water supply for boilers
Water circulation and boosting for industry
Other clean fluid transportation
- Q: What are the important parameters of the pump?
- The head is the unit weight of liquid pump pumping from the inlet of the pump (pump inlet flange) to the outlet of the pump (pump outlet flange) energy value. Effective energy is a Newtonian liquid through the pump unit is obtained. The N m/N=m, the height of liquid column pumping liquid used, referred to as meters.Speed nThe speed is the number of revolutions per unit time of the pump shaft. It is indicated by the symbol n. The unit is r/min.Cavitation allowance NPSHCavitation margin, also called net positive suction head, is the main parameter to indicate the cavitation performance. The cavitation margin has been expressed by delta H at homePower and efficiencyThe power of water pump usually refers to the input power, that is, the power transferred by the prime mover to the pump shaft, so it is also called shaft power. It is expressed by P;The effective power of the pump, also known as the output power, is expressed in Pe. It is the effective energy obtained by pumping the liquid out of the pump in unit time
- Q: Variable flow pumps are variable pumps
- To be exact, variable pump means variable displacement. Because if the displacement does not change
- Q: What is the lift off the dead center point? This is a straight mark about the water pump. What is the function and the relationship between the design head and the pump head? ThanksWhat exactly is the dead point lift? What's the function of this indicator?
- In a dead head will be relatively high, the main downstream equipment and pump, if a dead head high, so the design pressure of the pump needs downstream equipment will be relatively large, resulting in the cost increases, so close a better head lower dead point.
- Q: What does "efficiency" mean in a water pump catalog?
- The efficiency of the water pump nameplate refers to the maximum efficiency that the pump can reach at the rated speed
- Q: What is pump suction work?
- Pumping loss refers to the loss of work done by the piston of the engine in the pumping process compared with the theoretical cycle. Theoretical pump Qigong to remove the loss of pump gas after the actual pump qigong.
- Q: What is the function of the heating pump system for the water pump design?
- Will cause some of the internal friction gap disappeared, the coupling center damage. In this case, starting the pump inevitably results in vibration, friction, etc.
- Q: What are the main performance parameters of hydraulic pumps?
- Displacement and flowDisplacement refers to the pump (or motor) every turn a week, by the size of the sealing chamber geometry variable discharge (or enter) the volume of liquid, commonly used unit is ml/r (ml / rev). Displacement can be changed as a variable pump (or variable motor), and the displacement can not be changed into a quantitative pump (or a quantitative motor).Actual flow is the amount of flow at the outlet (or inlet) when the pump (or motor) is operating. As the pump itself leaks, the actual flow is less than the theoretical flow. As the motor itself has an internal leakage, to achieve the specified speed, in order to compensate the leakage, the actual flow of input must be greater than the theoretical flow.
- Q: I want to know the concrete under 60 type pump performance, it is mainly the pump long spiral bored piles, such as the diameter of the pump, transportation distance, pumping height and so on, thank you!
- Maximum theoretical vertical transfer distance is m 270Maximum theoretical level conveying distance m 1200Distributing valve form S pipe valve (whole casting)
- Q: How accurate is the metering pump?
- Three automatic compensation valve device widely used in diaphragm metering pump, especially with suction height requirements, can only be used by three separate Fujian (safety valve, discharge valve and oil supply valve) compensation device.
- Q: What's the difference between a centrifugal pump and a centrifugal pump? What are they used for?
- As the name suggests, centrifuges are machines that achieve centrifugal effects by centrifugal action. And you say the centrifugal pump is only specific, and the same as the pump
Send your message to us
Vertical Multistage Centrifugal Pumps with High quality
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 500 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches