Vertical Multistage Centrifugal Pumps with High quality
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 500 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
FEATURES:
Vertical Multistage grundfos water Pump is the latest model with the features of energy-saving and less space demand, easy to install and has stable performances.
1. With its 304 stainless steel shell and wear-resistant axle seal, there is no leakage and it can live long service life.
2. With hydraulic equilibrium to balance the axial force, the pump can run more smoothly, less noise, which can be easily installed in same level pipelines, enjoying better installation conditions than DL model.
3. With these features, GDL Pump can easily meet the needs and requirements for water supply and drain foe high building, deep well and firefighting equipments.
Flow range: 1.4-1 94.4CBM/h
Head range: 20-230m
Speed: 2900r/min
Maximal pressure of system: 2.5MPa
Medium temperature: -15~°C+120°C
Environment temperature: ≤+40°C
Motor protection level: IP44, IP54
Insulation grade: B, F rank
Rotation direction: Clockwise
APPLICATIONS:
Domestic water supply for buildings
Fire water supply for buildings
Water supply equipments
Water supply for boilers
Water circulation and boosting for industry
Other clean fluid transportation
- Q: Fire pump and shower pump flow head selection, high resolution.
- 2, the volume is greater than 10000 is less than 25000, the minimum water consumption of indoor fire hydrant is 15L/s
- Q: Troubleshooting of diaphragm pump
- The ratio of flow to water weight at a specific weight of --68F. 68F water has a specific gravity of 1Static suction head - the vertical distance from the liquid level to the central line of the pump. The pump shall be above the level of the liquid.Vapor pressure the pressure of all the steam on the free surface of the liquid. In any pump operating system, the operating pressure shall not be lower than the vapor pressure, otherwise the steam will be partially or completely cut off into the pump fluid. Viscosity - because of the presence of friction in the fluid, the property of viscosity gives the fluid resistance to flow.Water hammer action -Water hammer is a sudden power failure, or in the valve closed too fast, due to pressure, flow of inertia, produce water shock waves, like hammer hammer, so called water hammer. The force produced by the flow of water shock waves can sometimes be very large, thereby damaging the valves and pumps. Water hammer effect refers to the inside of the water pipe, the pipe wall is smooth, flow freely. When the opening of the valve suddenly closes, the flow of water to the valve and the tube wall, mainly the valve, will produce a pressure. As the pipe wall is smooth, the subsequent water flow in the role of inertia, the fastest reach the maximum and damage, which is the water conservancy "water hammer effect", that is, "positive water hammer.". This factor should be taken into consideration in the construction of water conservancy pipelines. On the contrary, the valve closed in a sudden opening, it will produce water hammer, called negative water hammer, but also a certain destructive power, but not the former big.. Causes and treatment methods of common failures of diaphragm pumps:
- Q: What are the important parameters of the pump?
- Because the lift refers to the effective energy, pump output unit of heavy liquid obtained from the pump so that the product of head and the mass flow rate and acceleration of gravity, is the effective energy output from the pump in unit time of liquid -- effective power pump:Pe= P gQH (W) = QH (W)In the p - density of liquid pumping (kg/m3);Gamma - pump heavy liquid delivery (N/m3);Q - pump flow (m3/s);H - pump lift (m);G - gravitational acceleration (m/s2)The shaft power P and effective power Pe is the difference of power loss in the pump, the size of the pump efficiency to measure the efficiency of the pump. As the effective power and shaft power ratio, with ETA said.
- Q: The main factors affecting the performance of centrifugal pumps
- The specific speed is deduced by the law of hydraulic similarity, and the similarity between the hydraulic characteristics of centrifugal pumps is similar. In centrifugal pumps, the specific speed is often interpreted as: the pump works at the highest efficiency, generating a lift of LM, a flow rate of 0.075m, and the power consumed by the /s at 0. 735kW
- Q: I live on the 8 floor. Often there is no water. Life is very inconvenient. What kind of pump do I have to install? What should I pay attention to when I buy it? What's the pump for that brand? Should it be installed in that position?
- (8) check the suitability of the foundation and whether the size of the foundation corresponds to the size of the pump.(9) find the position of positive pump and motor, pump set and anchor bolt and the inlet and outlet flanges, to ensure that the flange torque of the pump conforms to the standard. Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition. It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
- Q: Operating procedures for measuring pumps
- First, preparation and inspection before starting1. Check to make sure that the drain line is equipped with a safety valve with the correct set pressure.2. Check the screws for the liquid end parts.
- Q: I want to know the concrete under 60 type pump performance, it is mainly the pump long spiral bored piles, such as the diameter of the pump, transportation distance, pumping height and so on, thank you!
- Maximum theoretical vertical transfer distance is m 270Maximum theoretical level conveying distance m 1200Distributing valve form S pipe valve (whole casting)
- Q: Types and differences of pumps
- Classification and working principle of pump by structureClassification of pumpsInvolved pump standard product types are also very much, a centrifugal pump, metering pump, screw pump, reciprocating pump, hydraulic pump, submersible pump, oil pump, water pump, pressure test pump, vortex pump, cryogenic pump, vacuum pump, roots pump, molecular pump, gear pump, mud pump, corrosion-resistant pump deep well pump, water pump, mixed flow pump, axial flow pump, boiler feedwater pump, liquid pump, injection pump, chemical pump, pump plugging and no leakage pump, plastic pump, fire pump and so on, there are many. Its name is divided according to some conventional classification methods such as pump vane pump volume, pump etc., some are divided by purpose such as sewage pump, pump and other health, some names are more random as diffusion pump, liquid nitrogen pump. As long as the production of this product, with standard requirements, through a certain application and approval procedures may produce a new The standard, but sometimes the content also has a repeated cross, quite. The domestic and foreign standards, the domestic standard is more than the number of foreign standards. In general, such as centrifugal pumps are widely used, the production history of the pump more standard (total standard centrifugal pump up to more than 100). As new standard pump leakage pump this rapid development is relatively small. This paper introduces the structure and working principle of the pump according to the classification of the
- Q: What are the differences between the sewage pump and the clean water pump?
- The main difference between the sewage pump and the clean water pump is that:Impeller and runner design, as well as other parts of the configuration are very different.1., in order to prevent clogging of sewage pump, the main design of large flow channel, so naturally lead to relatively low efficiency, so the head is generally not high. Clear water pump flow smaller, smaller clearance, the head is relatively high.
- Q: Why is the submersible pump tripped on an electrical switch?There is no electrical leakage protection, directly connected to the circuit breaker, and when the switch on, the circuit breaker jumpedI checked the line is good, the pump did not break down, is not the water pump?
- Submersible pump cable or motor insulation is damaged.3) motor water solution
Send your message to us
Vertical Multistage Centrifugal Pumps with High quality
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 500 unit/month
OKorder Service Pledge