Loop Tie Wire/ Binding Wire Packing Bind Wire HighQuality
- Loading Port:
- Tianjin
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 m.t.
- Supply Capability:
- 5000 m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.Structure ofLoop Tie Wire/ Binding Wire Packing Bind Wire HighQuality Description:
Loop tie wire provides protection against rust and corrosion. Fine grains, adjust, eliminate defects than ordinary black iron wire is more soft, better flexibility, softness and uniform, consistent color is mainly used in construction mining chemical welding net hangers rework after annealed wire become soft, flexible, construction tie wire binding reinforcement effect more.
Loop tie wire is widely used for binding uses, such as tying of sacks and other bagging. This kind of wire is also widely used in securing the position of reinforcing bars during concrete placement.
2.Main Features of Loop Tie Wire/ Binding Wire Packing Bind Wire HighQuality:
• Durable
• Practical
• Convenient
• Use widely
• Inexpensive
3. Loop Tie Wire/ Binding Wire Packing Bind Wire HighQualityImages
4.Loop Tie Wire/ Binding Wire Packing Bind Wire HighQuality Specification
Wire Gauge | SWG in mm | BWG in mm | In Metric System mm |
8# | 4.06 | 4.19 | 4.00 |
9# | 3.66 | 3.76 | |
10# | 3.25 | 3.40 | 3.50 |
11# | 2.95 | 3.05 | 3.00 |
12# | 2.64 | 2.77 | 2.80 |
13# | 2.34 | 2.41 | 2.50 |
14# | 2.03 | 2.11 | |
15# | 1.83 | 1.83 | 1.80 |
16# | 1.63 | 1.65 | 1.65 |
17# | 1.42 | 1.47 | 1.40 |
18# | 1.22 | 1.25 | 1.20 |
19# | 1.02 | 1.07 | 1.00 |
20# | 0.91 | 0.89 | 0.90 |
21# | 0.81 | 0.813 | 0.80 |
22# | 0.71 | 0.711 | 0.70 |
23# to 34# also available for galvanized iron wire. |
5.FAQ
We have organized several common questions for our clients,may help you sincerely:
①How about your products?
We are a professional manufacture with many years of experiences, we have advanced facilities for production, and most of the products, like Loop tie wire. Annually more than 10000 tons wires and wire mesh are exported to markets all over the world. Different kinds of wires and mesh are available according to customer’s requirements.
②what is the Main Export Markets of Wire?
Eastern Europe
North America
Mid East/Africa
Central/South America
Asia
Western Europe
Australasia
③How long can we receive the product after purchase?
In the purchase of Loop tie wire within three working days, We will arrange the factory delivery as soon as possible. The pacific time of receiving is related to the state and position of customers. Commonly 15 to 20 working days can be served.
- Q: The wire is size 10AWG and will be to install a small fluorescent light in a closet. It is coming off of a typical electric outlet. I know someone who is witing it with commercial wire and I think it may be dangerous. Is it?
- What do you mean by commercial wiring? The gauge of the wire or what it's connected to does not, in itself, make it commercial.
- Q: 14. Three parallel wires carry currents, with magnitudes and in the directions shown in the figure below. The wires all lie in a plane, and are all 2 m long, with separations between them as shown in the figure. What is the total force on wire #3 due to wire #1 and wire #2? Wire 1 : 6A, 2.5 m from Wire 3 ---------------------gt;Wire 2: 3A, 1.0 m from Wire 3 lt;--------------------Wire 3: 3A ---------------------gt;Can't figure it out, any hints/suggestions?
- The formula for force between wires is: (?/2π)(current1)(current2)(length/r) ? = 4πE-7 Tm/A r=distance between wires For this problem, you would just find the force on wire 3 of each one separately. Since wire 2 is going opposite direction as wire 3, they repel each other, while wire 1 and wire 3 attract each other since they are going same direction. I get Fwire1 to be 2.88E-6 N, and Fwire2 to be 3.6E-6N. Then subtract them since opposite forces, and since Fwire2 is stronger, the force would be 7.2E-7 N away/repelling.
- Q: the 2 wires that is connected from the key hole is cut .. how to fix or replace?
- If there enough wire left on each side of the cut, say 1, then you could bear about 1/4 of the wire on each side and solder the wires back together making sure you are soldering the same wires together and wrap each soldered connection in electrical tape so they are not able to touch each other. Then a final wrap of tape around them both. If you are not up to soldering you could go to an auto parts shop and get a crimp connector to do the job, again bearing of wire is needed to get a contact through the cut area. If the cut is closer to the switch then there is no option but to replace the switch.....
- Q: I'm replacing the ground wire in a chandelier because it has been cut by the previous owner when it was removed from the ceiling. Overall it is pretty simple and I have everything diagramed. When I went to Radio Shack and bought the replacement wire they gave me 18 gauge solid insulated hookup wire. It looks totally different. The ground wire is a braided copper wire (7 strands). Should I go back and take my copper wire with me and get copper or is what I have just as good? An electrician will do the installation of the chandelier into the ceiling.
- Ground wire is common convention at electrical boxes. Ground wire from point to point in any circuit is part of the wiring cable used. On a ceiling light, there is little danger of electrical shock if there is no ground wire from the fixture to the metal box. However, your replacement wire will work just fine.
- Q: well i've been asking for quite sometime on the correct wiring of a bathroom fan up to the same circuit as my light in the bathroom but i believe i've figured out. but i have a question now about the wire guage.the wire guage in the house is the standard solid 12 or 14 i think(house built in 50's) and the the wire that came with the bathroom fan looks a little smaller or about same size but it's braided .it should be fine to splice the two right?
- The wires for the fan are probably stranded and twisted, or braided, but you certainly can splice them to solid wire using an insulated wire nut. Just make sure when you put the nut on you don't push the stranded wire off the solid wire, which will result in a not so solid and safe connection.
- Q: two straight and parallel wires are separated by 6 cm. there is a 2 A current flowing in the first wire. if the magnetic field strength is found to be zero between the two wires at a distance of 2.2 cm from the first wire, what is the magnitude and direction of the current in the second wire?
- If the magnetic field at 2.2cm is zero it means that at that distance the fields produced by the two wires cancel out. At 2.2cm from the first wire the field strength is B= uI/ 2pi r ... . where u is the permitivity of free space, 4.0 x 10^-7 N/A^2 B= (4.0 x 10^-7 N/A^2)( 2 A)/ 2(3.14)(0.022m) B=( 8 x10^-7)/(0.138) B= 5.79 x 10^-6 Tesla The magnitude of the magnetic field from the other wire must be equal in magnitude at 3.8cm away (6- 2.2) and opposite in direction. Using the right hand rule (thumb points in direction of current and fingers curl around the wire to show the direction of the magnetic field) you can see that for the magnetic fields to be in opposite direction between the two wires the current must be flowing in the same direction as the first wire. Using the formula for magnetic field strength you can then determine the current needed. 5.79 x10^-6 T= (4.0 x 10^-7) I/ 2 (3.14)(0.038m) THen solve for I I= (5.79 x 10^-6 T)(2)(3.14)(0.038m)/ 4.0 x 10^-7) I= 3.45 A Therefore there is a current of 3.45A in the wire and it is flowing in the same direction as the first.
- Q: I did an engine swap with some friends and everything is in place, from the rebuild 700R4 w/ a shift kit, to the rebuild 350 bored .30 over. But all I have left to do is the wiring, but have no idea how to. So about how much would it cost to have a professional finish the wiring?
- Wait a sec. You recommend if Congress provides the administrative large potential to inspect on individuals, it will use it? Benghazi is a witch hunt being devised from a tragedy. it particularly is Republicans searching for political hazard. The AP surveillance is a hundred% criminal because of the fact congress exceeded a regulation announcing it particularly is under our final president. The IRS difficulty, is a localized adventure in Cincinnati, which got here approximately and became got here upon final 12 months. The operative became released. The president had not something to do with any of this. i discover the AP tale aggravating, besides the shown fact that it particularly is totally criminal. i discover the IRS difficulty troubling, besides the shown fact that it became dealt with some distance faraway from presidential notice. relax. i'm effective you will locate yet another marvelous merchandise to distract you quickly.
- Q: i need to know if my wires are hooked up right
- you must have a heat pump then. Basically the terminal connections should be the same as how those wires are connected at the indoor air handler.If you did not note the colors and the terminals they were connected on the old stat then you may have to check the air handler.
- Q: so there are 3 different wires coming into the switch. 1 black wire and 2 white wires going to the attic fan (i assume one for high and one for low). the power seems to be coming from the black wire which has inside of it, one white wire (neutral) one black wire (hot) and one bare wire (ground).. the same for the 2 white wires. the switch goes up (^) for high and down (v) for low and has 3 places to attach the wires to. the top, the bottom and the middle.. can someone tell me how to wire this damn thing?
- Wire nut all the white neutral wires together. Wire all the bare ground conductors together. The the hot wire will attach to the terminal labeled common and one each of the other 2 black wires will attach to the high and low terminals. If it runs high while low is selected etc, the swap the last 2 and try again. PS any time there are multiple conductors in an overall covering it is called a cable. You have for example 1 black cable and 2 white cables.
- Q: i have a 92 saturn and bought the wire harness, i put all the wires together and all that turned on was the theft light that comes on when you take off the face after that i tried putting the red and yellow wires together and it worked, just without the key having to be in the ignition and i think that is why the stereo gets so hot so can youall tell me how to wire it correctly?
- The red is the main power or acc power that comes on when car key is turned. The yeallow is for the memory for radio. Another word when u store a preset radio station that yellow wire supplies continues power to store mem for ever or untill u have to change batt. The reason y it worked when u hooked yellow and red to gether is they where both getting power. If one dosent get power it will no work. Check radio fuses for the yellow wire to see if it out. If u have manuel to car that would help. I had a mustang that with the yellow wire was dead i traced the wire tried to find the prob but could not. I ran a wire from batt to radio where the yellow wire hooked up. That is the same thing just try to keep the wire away from hot areas and door jams try to runn it through the firewall of the car.
Send your message to us
Loop Tie Wire/ Binding Wire Packing Bind Wire HighQuality
- Loading Port:
- Tianjin
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 m.t.
- Supply Capability:
- 5000 m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords