• Horizontal Single Stage Fire Pump System 1
Horizontal Single Stage Fire Pump

Horizontal Single Stage Fire Pump

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
5000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Description

horizontal single stage fire pump is newly developed according to market needs.Its performance,technical conditions conform with international standard ISO2858 and requirements for national standard GB6245-2006《Performance requirements and test methods for fire pumps》.

Applications

It has been widely used in fire fighting and living water supply of industry the residence buildings.

Parameter range

Inlet diameter :50-200mm(2"-8")

Capacity:5-110L/s

Head:0.31-1.27MPa

Rate of rotation:2900r/min、1450r/min

Power:4-110kW

Two seal types: stuffing seal or mechanical seal

Structural Characteristics

  XBD-I series horizontal single stage fire pump set is mainly made up of 1.pump cover 2.impeller 3.shaft 4.seal ring 5.packing ring 10.Suspension bearing parts 12 .etc.

  Pump casing and pump cover of XBD-I series horizontal single stage pump are split from back of impeller,namely,back-open structure.It is convenient to maintain,when maintaining,pump casing,suction pipe,discharge pipe shall not be dismantled,so rotor parts can be taken out for maintenance easily.

   Pump casing(namely,pump body and pump cover) composes pump working room.Impeller,shaft and rolling bearing are rotors of pump.Suspension bearing parts support the rotor parts,and rolling bearing bears the radial force and residual axial force of pump.

    To balance the axial force of pump,there are seal rings on the front shroud and back shroud of impeller,and there is balancing hole on the impeller back shroud.Some of the pumps do not have too much axial force,so there are no seal ring or balancing hole on the impeller back shroud.

    Pump seal is made up of packing gland 9,shaft sleeve 8 and packing 11,or mechanical seal is applied to avoid air getting inside or too much water leakage.

    There is a shaft sleeve through the packing cavity to avoid shaft abrasion.There is o-ring between shaft sleeve and shaft to avoid the air getting inside or water leakage.

    Driving way of pump is connected through coupling and motor.Pump rotates clockwise from the direction of drive.

Q: What are the uses and precautions of magnetic pumps?
Notice of use:1. prevent particles from enteringHas the ferromagnetic impurities and particles into the magnetic actuator and bearing friction is not allowed.The transport of crystallization or precipitation of the medium to the flushing (after pumping water, poured into the pump cavity drained after running 1min), in order to ensure the service life of bearing.The transport medium containing solid particles, the pump flow tube inlet filter.
Q: You'd better point out the details.... There are 2 best ways of experience and formulaCan you say a simple point, such as multi-stage pump, when the pump is higher than the motor, 30 wire is the next mouth how to do?
Alignment methods and requirements:1, check two feeler dial gauge or flange coupling the parallelism, usually with clearance between the both ends of the side instead of difference, in the circumferential direction every 900 measure, the maximum and minimum gap gap difference (Ab) less than or equal to 0.3 mm.2, the coupling flanges outside the park up and down, left and right four position to check whether they are in the same line, C less than or equal to 0.1 mm.When looking for a positive C, it will affect (a - b), finding the right (a - b) will affect the C, to balance each other. It's easier for an unskilled comrade to find C (a - b) first, and then find a positive one. Through the adjustment of the motor at the foot of the gasket thickness (Ab) and meet the requirements of C.Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition.It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
Q: How many millimeters is the diameter of the water outlet of the four inch pump?
Here is a 4 inch inch, not rural, 1 inches =25.4 mm, 4 inches is approximately 100mm, with DN100 pipeline.
Q: What is the principle of a turbopump?
The working conditions of the turbine are different from those of the medium used, so the structure of the turbine is varied, but the basic working principle is similar. The most important component of a turbine is a rotating element (rotor or impeller) mounted on a turbine shaft with blades uniformly arranged along the circumference. The energy of the fluid is converted into kinetic energy in the flow through the nozzle, and when the fluid passes through the rotor, the fluid impacts the blade and drives the rotor to rotate, thus driving the turbine shaft to rotate. The turbine shaft drives the other machinery directly or through the transmission mechanism, and outputs mechanical work.
Q: Why should I pump the pump before starting the centrifugal pump?
Before the operation of the centrifugal pump, the pump must be filled with water, exhaust the air, before you start the operation. All centrifugal pumps should be handled this way, which is the centrifugal pump itself.The way of water diversion:1., in the centrifugal pump outlet increase water diversion pump (usually using vacuum pump), start the centrifugal pump before, start the vacuum pump, the centrifugal pump air into;2. increase the vacuum water tank before the intake of the centrifugal pump to meet the working conditions of the centrifugal pump;3. in the centrifugal pump inlet water increase valve, to meet the working conditions of centrifugal pump;4., if the water tank or water tank volume of water level is higher than the centrifugal pump position, the first operation of the front row empty, usually do not empty, you can use.
Q: What are the main performance parameters of hydraulic pumps?
Main performance parameters of hydraulic pump:1. Hydraulic pump pressureHydraulic pump operating pressure is the pump (or motor) in actual work output (or input) oil pressure, determined by the external load.Rated pressure refers to the maximum pressure under continuous running in accordance with the test standards under normal working conditions. The size of the pump is limited by the service life, and the service life of the pump (or motor) will be shorter than the design life if it exceeds the rated pressure. When the work pressure is greater than the rated pressure, it is called overload.
Q: What is the main difference between SK water ring vacuum pump and 2BV water ring vacuum pump?
The unified corrosion resistant design of bronze impeller improves the corrosion resistance of the pump, and the stainless steel material is more suitable for more severe applications;
Q: How can I buy a pump?
Selection principle of pump:1, so that the selected pump type and performance parameters meet the unit flow, lift, pressure, temperature and other requirements, the most important thing is to determine the voltage, the maximum lift, and when the head high reached much traffic.
Q: Pneumatic diaphragm pump compressed air pressure is 4 kg, the discharge pressure is how big?
Have to know the ratio, pneumatic pump, if high pressure, you can have 2:1,3:1
Q: Why is the submersible pump tripped on an electrical switch?There is no electrical leakage protection, directly connected to the circuit breaker, and when the switch on, the circuit breaker jumpedI checked the line is good, the pump did not break down, is not the water pump?
Submersible pump cable or motor insulation is damaged.3) motor water solution