Horizontal Booster Water Pump for Boiler Feed
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Horizontal Booster Water Pump for Boiler Feed
1.Structure of Horizontal Booster Water Pump for Boiler Feed
The high presuure boiler feed multistage water pump is a horizontal multistage centrifugal pump and suitable for transporting pure water,both ends of it are supported,the casing portion is a senctional form,it is connected and actuated by motor via a resilient clutch.From the driven direction,the pump rotated direction is clockwise.
2.Main Features of Horizontal Booster Water Pump for Boiler Feed
• High Effiency
•Low noise
•Long life, OEM and ODM are welcomed.
3.Horizontal Booster Water Pump for Boiler Feed Images
4.Horizontal Booster Water Pump for Boiler Feed Specification
Material |
Cast iron and as customer's request |
Temperature |
Less than 150°C |
Flow rate | 3.75-300m3/h |
Head | 75-1000m |
Medium temperature | 0 ~170°C |
Operation pressure | ≤40 bars |
5.FAQ
①What is the applications?
Power Station,Industry Water Supply
②How to guarantee the quality of the products?
We have established the international advanced quality management system,every link from raw material to final product we have strict quality test;We resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance. Normally, We have 1 year warranty.
- Q: Know flow and lift how to calculate the pump power?
- N=Q.H.g. P / nN - motor power, kWH - pump head, MQ - pump flow, m^3/sG - gravity acceleration g=9.81
- Q: If the suction pump does not have enough suction range, you need to add a vacuum pump to increase the suction stroke. How do you install the suction pipe of the vacuum pump? Water pump impeller is not closed, it is normal that the vacuum pump is unable to pump suction pipe to a vacuum, is it because the water pump outlet pipe connected to the role of the check valve? But the water pump, outlet pipe, check valve sealing performance can achieve the function of non leakage?
- The role of the check valve:"[the water pump impeller is not closed" refers to the pump suction pump before the water without water inlet pipe and water outlet pipe gas should be connected] is a connector, a connector, still can make the level surface, in order to prevent the water flow along the pipe, until it reaches the level of the flush, then increased check valve, or pumping up water will not leak?Vacuum suction principle of self suction pump:Assuming that the pump connected with the water inlet of a sealed container, the container has plenty of water, since the start of a water pump, water is thrown out of the water impeller pump body, water inlet seal vessel due to the extraction of water to form a vacuum cavity, this assumption will be connected to vacuum cavity and exposed to atmospheric conditions of water, water at atmospheric pressure under the effect of entry into the vacuum chamber".....
- Q: What are the starting and stopping procedures for centrifugal pumps?
- Operation method and operation procedure of self-priming centrifugal pumpClick number: 440 release time: 2011-7-24Centrifugal pump method, centrifugal pump operation steps, centrifugal pump use steps
- Q: How to distinguish the flow and displacement in the hydraulic pump? What's the difference between the two?
- For example, once you sprinkle water from the tank to the ground, one shot of water is 1000 milliliters, which is equivalent to displacement, once (pump turn) 1000 ml.,
- Q: Does the reservoir water heater press the booster pump (high marks)?
- 60 liters of water storage should be able to drive two bathrooms at the same time bath! Water storage water heater generally does not need booster pump, as long as there is a little pressure, the water heater is filled with water, as long as the tap water can do. You can turn off the hot water valve and see only the amount of water in the cold water. If hot water is much smaller than cold water, it is the reason for the heater. Can you check the water mixer is normal, the one-way valve is installed in reverse.
- Q: Rules for operation of centrifugal pumps
- Operating rules:1, before starting to check whether the water pump foot loose, coupling shield, and motor fan blade cover is intact, in order to ensure the safety of equipment and personal safety.2. Check whether the inlet valve is open and open as fully as possible. Is the outlet valve closed, open the bleeder valve, exhaust until there is no air, and close the bleeder valve. At the end of the valve to the pipeline in the pump cavity filled with water.
- Q: If the calculation of the required pump flow is 45, lift 110, and the actual pump flow 100, head 125, what will happen in operation? Can I use it properly?
- Centrifugal pumps are too big to measure.There is a reason why the centrifugal pump does not measure up:The pump inlet pipe blockage, leakage.The pump inlet pressure is too low.
- Q: What are the main performance parameters of the pump?
- The amount of liquid supplied by a pump in unit time. Volume flow Q, unit m3 / s. There is mass flow G, unit is kg / s.
- Q: How accurate is the metering pump?
- In addition, when the oil supply is too large or the pipeline pressure rises unexpectedly, the volume of the liquid in the hydraulic chamber can be changed, thereby affecting the stability of the flow and reducing the metering accuracy of the pump. In order to solve the problem of how to stabilize the measurement accuracy of metering pump metering pump flow, how stable, the three valve device. The so-called actual refers to the combination of three functions including compensation, discharge and safety protection device or device supporting the hydraulic chamber, according to its action principle is different, is divided into automatic compensation and forced compensation two three valve device.
- Q: What's the submersible pump?What is a submersible pump, and what about it?
- Not afraid of water, because it is placed in the water itself to cool themselves, you can use for a long time. The amount of water pumped and the height of the water now basically meets the needs of a small amount of individual and a large number of factories. This is the submersible pump, the water pump in the water. You can see.
Send your message to us
Horizontal Booster Water Pump for Boiler Feed
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords