• High Pressure Multistage Centrifugal Boiler Feed Water Pump System 1
  • High Pressure Multistage Centrifugal Boiler Feed Water Pump System 2
  • High Pressure Multistage Centrifugal Boiler Feed Water Pump System 3
High Pressure Multistage Centrifugal Boiler Feed Water Pump

High Pressure Multistage Centrifugal Boiler Feed Water Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 DG High Pressure Multistage Centrifugal Boiler Feed Water Pump

1.Structure of  DG High Pressure Multistage Centrifugal Boiler Feed Water Pump Description

 

Boiler Feed Centrifugal Multistage Water Pumpis used for transporting pure water (particles density shall be max.1%by volumeand granular size shall be max 0.1mm in dimeter) of the liquids with physical and chemical properties similar to pure water. Type MD pump is applied with wear resist material, especially suitable for mineral drainage. The particles density shall be max. 1.5% (Max. of the granular diameter is 0.5 mm).The liquid temperature ofD, MD pumps shall be lower than 80°C.

 

2.Main Features of the DG High Pressure Multistage Centrifugal Boiler Feed Water Pump

• Compact structure, good appearance, low construction

Operation stably, same inlet and outlet

•Convenient installation and maintenance

Customized design is available, OEM and ODM are welcomed.

•Horizontally and vertically installation as different pipeline system

3. DG High Pressure Multistage Centrifugal Boiler Feed Water Pump images

High Pressure Multistage Centrifugal Boiler Feed Water Pump

4. DG High Pressure Multistage Centrifugal Boiler Feed Water Pump Specification

 

Item

Multistage Pump

Multistage Pump

Horizontal Multistage Pump For Pure Water

Model

CMD

Material

Cast iron,Stainless steel

Mode

Horizontal

Color

Blue

Temperature

<=80°c< span="">

Seal

packing seal

Theory

Centrifugal Pump

Structure

Multistage Pump

Usage

Water

Power

Electric

Standard or Nonstandard

Standard

Fuel

Diesel

Pressure

High Pressure

Application

Hot and cold pure water

Outlet Diameter

40-500mm

Capacity

6-1250 m3/h

Head

75-1800m

Rotation Speed

1450-2950r/min

Power

5.5-2400kW

Certificate

ISO9001

Feature

High efficiency,Easy maintenance 

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

Q: The suction pump has a nominal suction range of 30 metersHow deep can a well be sucked?Well, sixteen meters,
Vacuum pump plus form must not reach a standard atmospheric pressure vacuum, so the general can absorb 8 meters is very good, and the self suction pump itself and loss, the horizontal self-priming pump can suck on basic 4~6 meters is very good, self-priming pump. Suction lift of 30 meters is purely in the Mongolian people, does not comply with the laws of nature, obvious anti science.
Q: Is the diaphragm pump and the drain pump one?
Generally composed of actuators and valves.Pneumatic diaphragm pump, which has four kinds of materials: plastic, aluminum alloy, cast iron, stainless steel. The electric diaphragm pump has four kinds of materials: plastic, aluminum alloy, cast iron and stainless steel. Diaphragm pump diaphragm according to different liquid media, respectively, NBR, chloroprene rubber, fluorine rubber, PTFE, poly 46 ethylene to meet the needs. Placed in a variety of special occasions, for pumping various media.
Q: What is the principle of a turbopump?
A machine that converts the energy contained in a fluid medium into mechanical work [turbine]. Also known as turbines, turbines. Turbine is the transliteration of English turbine, derived from the Latin word "turbo", meaning "rotating object". The working conditions of turbines are different from those of the employed ones, so their structure types are various, but the basic working principle is similar. The most important component of a turbine is a rotating element (rotor or impeller) that is mounted on a turbine shaft and has blades uniformly arranged along the circumference. The energy of the fluid is converted into kinetic energy in the flow through the nozzle, and when the fluid passes through the rotor, the fluid impacts the blade and drives the rotor to rotate, thus driving the turbine shaft to rotate. The turbine shaft drives the other machinery directly or through the transmission mechanism, and outputs mechanical work. According to the turbine working fluid used can be divided into different turbine (used as a power source of Hydropower Station) and steam turbine (used in thermal power plant, ship propulsion), gas turbine (used as jet propulsion, ship power, and power plants, with a small peak load power station and air turbine (only) as a small power).
Q: What's the difference between non negative pressure and variable frequency water pump?
No negative pressure is superposed pressure intelligent frequency conversion equipment, pump frequency operation is no negative pressure difference, and the variable frequency pump, variable frequency pump is advanced municipal tap water tank or pool, pump from the tank or pond water pressure to set pressure to the pressure water supply, and no negative pressure directly from water the municipal pipeline, using the original municipal 2~3 kilograms of pressure
Q: What are the characteristics of a vertical multistage centrifugal pump?
Vertical multistage centrifugal pump system using the latest international advanced IS type hydraulic model based design for high efficiency centrifugal pump with multi segment, the soft packing or mechanical seal, has the characteristics of high efficiency, large flow, high lift, no leakage, a wide range of performance, safe operation, stable operation and long service life and small area.
Q: Rules for operation of centrifugal pumps
5, before you stop, you should gradually close the outlet valve, then turn off the power supply.6, with the check valve line, in ensuring the check valve intact, without closing the outlet valve, check the pump cavity, no air can be directly switched on.
Q: What does centrifugal pump mean horizontally?
In other words, pump casing and pump body along the horizontal center of the pump leaves into the upper and lower halves, so that when the pump leaves the pump cover open, you can pump and bearings as a whole pumping out. No need to remove the pipe. I don't know. Do you understand?.
Q: What is the working pressure of the hydraulic pump in the hydraulic transmission system?
Generally speaking, for the fixed size, not limited equipment, the pressure can be selected lower, walking machinery heavy equipment pressure should be selected higher.If the load is selected, the working pressure is as follows:Load <5kN, working pressure <0.8~1MPa;Load 5~10kN, working pressure 1.5~2MPa;Load 10~20kN, working pressure 2.5~3MPa;Load 20~30kN, working pressure 3~4MPa;Load 30~50kN, working pressure 4~5MPa;Load 50kN, working pressure =5MPa;For example, the system work pressure of various machines is as follows:Grinder 0.8~2MPaModular machine tool 3~5MPaLongmen planer 2~8MPaBroaching machine 8~10MPa agricultural machinery, small construction machinery, construction machinery, hydraulic drilling machine 10~18MPa hydraulic machine, large and medium-sized excavators, heavy machinery, lifting transportation machinery 20~32MPa.
Q: Pneumatic diaphragm pump compressed air pressure is 4 kg, the discharge pressure is how big?
Generally slightly lower than 0.4MPa, Zai 0.35Mpa or so, if the outlet is blocked, the outlet pressure will equal 0.4MPa
Q: Why does the centrifugal pump start with a closed valve and the axial pump starts with an opening valve?
The power of axial flow pump decreases with the increase of flow rate, and it is a steep curve, so the centrifugal pump starts with an open valve.