Heavily Galvanized Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Hot Dip Galvanized Steel Wire
(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .
(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .
(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.
(4) Tensile Strength Range
Size (mm) | Tensile Strength (mpa) |
0.15-1.60 | 290-550 |
0.65-1.60 | 400-550 |
1.61-6.00 | 400-1200 |
(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.
(6) Packing
Size (mm) | Coil Size | Spool Packing | Big Coil Packing | |
ID (mm) | OD (mm) | |||
0.15-0.26 | 6 inch | 1-14kg/spool |
|
|
0.27-0.60 | 8 inch | 1-100kg/spool |
|
|
0.61-1.60 | 12/14/16 inch | 1-100kg/spool | 250-400 | 400-770 |
1.61-6.00 |
| 14-500kg/spool | 450 | 800 |
508 | 840 |
(7) Zinc Coating
Meet GB/T 15393 standard.
Size (mm) | Weight of Zinc-Coating ( g/m2 ) | |||||||
A | AB | B | C | D | E | F | ||
A1 | B2 |
|
|
|
|
|
| |
≤0.25 |
|
| 30 | 20 | 18 |
|
|
|
>0.25-0.40 |
|
|
| 30 | 25 | 20 |
|
|
>0.40-0.50 |
|
|
|
| 30 | 20 |
|
|
>0.50-0.60 |
|
|
|
| 35 | 20 |
|
|
>0.60-0.80 | 120 | 110 |
|
| 40 | 20 |
|
|
>0.80-1.00 | 150 | 130 |
|
| 45 | 25 |
|
|
>1.00-1.20 | 180 | 150 |
|
| 50 | 25 |
|
|
>1.20-1.40 | 200 | 160 |
|
| 50 | 25 |
|
|
>1.40-1.60 | 220 | 180 |
|
| 50 | 35 | 30 |
|
>1.60-1.80 | 220 | 180 |
|
| 70 | 40 | 30 |
|
>1.80-2.20 | 230 | 200 |
|
| 80 | 50 | 40 |
|
>2.20-2.50 | 240 | 210 |
|
| 80 | 55 | 40 |
|
>2.50-3.00 | 250 | 230 |
|
| 90 | 70 | 45 |
|
>3.00-4.00 | 270 | 250 |
|
| 100 | 85 | 60 | 30 |
>4.00-5.20 | 290 | 270 |
|
| 110 | 95 | 70 | 40 |
>5.20-6.00 | 290 | 270 | 245 |
| 110 | 100 | 80 | 50 |
- Q: I'm replacing the door speakers in a 2001 Coupe Camaro with the factory sound system. I needed to know which wire was positive and which was negative so I bought a circuit tester. However, I keep getting the reading that both wires are positive. What could be causing this? I know the circuit tester works because I tested it on the battery terminals and it worked fine.
- You cannot use a circuit tester on speaker wires. It is not the correct tester. All you have to do is look at factory speaker it's marked positive and negative.
- Q: So on my ceiling fan I have a white, black, green, and blue wire. In the ceiling I have a green, white, black, red, and bronze wire. What gets connected to what? Thanks for the help!
- Redneck Texan is an idiot. Bronze does not go to blue. I think he is color blind and thinks the green in the picture is blue. Pat F85 is correct. The black on th fan is the blades and the blue on the fan is the lights. Black and red in ceiling can go to either blue or black on fan. Typically it would be black to black aNd red to blue.
- Q: I have an old house and am replacing a dimmer switch in the kitchen.The old switch is has only 2 wires coming out of the switch that are both black. From the wall 2 wires connect to the 2 black wires on the switch, one is black which I have concluded is hot and the other is red, which must be the common wire. My question is that there is a 3rd wired that is pushed into the electrical box that is capped and not being used. This wire is white. I can only assume that would be a ground wire, but why would it be white in color. Can you tell me what the coloring scheme was for wiring old houses? Now I can connect the switch and use only the black and red wire, but would like to ground it properly if possible.
- These would be normally. You should have them checked before you connect something. Black is hot White Neutral Red wires are also used for hot wires, switch legs (like to a ceiling fan), and are the second hot wire in 220-volt installations. Another useful application is the interconnect wire between two hardwired smoke detectors. A ground would be green or bare.
- Q: two straight and parallel wires are separated by 6 cm. there is a 2 A current flowing in the first wire. if the magnetic field strength is found to be zero between the two wires at a distance of 2.2 cm from the first wire, what is the magnitude and direction of the current in the second wire?
- If the magnetic field at 2.2cm is zero it means that at that distance the fields produced by the two wires cancel out. At 2.2cm from the first wire the field strength is B= uI/ 2pi r ... . where u is the permitivity of free space, 4.0 x 10^-7 N/A^2 B= (4.0 x 10^-7 N/A^2)( 2 A)/ 2(3.14)(0.022m) B=( 8 x10^-7)/(0.138) B= 5.79 x 10^-6 Tesla The magnitude of the magnetic field from the other wire must be equal in magnitude at 3.8cm away (6- 2.2) and opposite in direction. Using the right hand rule (thumb points in direction of current and fingers curl around the wire to show the direction of the magnetic field) you can see that for the magnetic fields to be in opposite direction between the two wires the current must be flowing in the same direction as the first wire. Using the formula for magnetic field strength you can then determine the current needed. 5.79 x10^-6 T= (4.0 x 10^-7) I/ 2 (3.14)(0.038m) THen solve for I I= (5.79 x 10^-6 T)(2)(3.14)(0.038m)/ 4.0 x 10^-7) I= 3.45 A Therefore there is a current of 3.45A in the wire and it is flowing in the same direction as the first.
- Q: I have a 1989 Nissan 240sx. Somehow the fan caught a hold of the wiring harness and tore all the wires. any idea how much it's going to cost?
- Buying a wiring harness will be prohibitive, and even transplanting one from a wrecking yard can be expensive. The harness can be repaired by splicing in pieces of wire where wire is missing and splicing together damaged pieces of wire. It is tedious but not particularly time consuming - I spliced in a section of harness after an engine fire in about 2 hours, working slowly.
- Q: What does the wire do for braces? What happens if you pull it out and everything else it ok?
- The wire in the braces is what does the trick .... without the wire braces are just metal objects on your teeth doing nothing! The wire that is placed in the grooves of the braces gently pull your teeth into the desired position!!!
- Q: I think I have heard about flat cable wires?maybe even flat electrical wires.where you can hide them behind a base board.is this true?what are they called/thx
- There okorder and didn't see it, but maybe I wasn't looking hard enough. I'm not sure if they still make it.
- Q: i need an egr wiring Diagram for a 2000 Chevy Malibu. the wires got pulled out of the weather tight connector. if anyone can help i'd appreciate
- Connector view for the GM linear EGR valve are as follows: Pin# A=gray/w black wire,Pin# B=solid black wire,Pin# C=brown/w white wire,Pin# D=brown/w white wire(see note) and Pin# E=solid red wire! NOTE since pin C+D have the same color wire the correct wire must be identified by checking the voltage with the KOEO (key on engine off) the right brown/w white wire should have a 5volt reference voltage with the key on engine off! Hope this helps.
- Q: i have old wiring for a stove that iam putting in ,a new box but i have only 3 wires 2 of them are white and 1 black how should i connect on a 4 wire receptacle? on the receptacle 1 white 1 green, 4 a ground then it says x then y ???????
- The new 4 wire receptacle needs a 4 wire circuit. It will have a white, a green or bare for ground, and a black and red for x and y.
- Q: The new light has 1 live, 1 neutral 1 earth wire, do i remove the earth connect the reds if so what about the 2 blacks?
- No! Wire the new light exactly like the light that you removed. If you don't remember what wire went where on the old light then you made a mistake by removing the old one without marking the wires or at least taking a cell phone picture or something. It sounds like there is probably more than one light fixture being controlled by that switch. It's hard to tell by your description. Electrons don't flow by wire color. There is no way to really tell what is going on by naming colors. Come back on here when you have a better description of what is going on. How many lights come on when you flip that switch? Is there more than one switch that controls that fixture? Which wires were hooked to the old light? Are any of the wires still wire nutted together? Don't be experimenting by hooking that earth ground wire to any other wire. Leave it hooked to the ground lug on the box. It has nothing to do with the light operating. It's for safety.
Send your message to us
Heavily Galvanized Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches