Gear Oil Heat Insulation Pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 5000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Heat Insulation Pump APPLICATION
*It applies to delivering medium not include solid particles and the temperature not higher than 300°C.
*It also applies to the site with heat insulated requirement in the process technology and outdoors installation at every cold area.
*External gear pump,the tooth form is composite formed by arc and sine curve.Keep warm and cooling the transferred medium and pump.
*Visocity larger than 1500cst,speed should be reduced.
Product name | bitumen gear oil heat insulation pump |
Model number | Heat Insulation Pump |
Type | Rotay pump,gear pump, Heat Insulation Pump |
Application Scope | Performance as transfer pump or booster pump in oil delivery system,and fuel pump for delivery,pressurization and injection in fuel supply system. As hydraulic pump supplying hydraulic power in hydraulic system. |
Material | 1.HT200; |
Capacity | 1.1~570m³/h |
Viscosity | 5×10-6~1.5×10-3m2/S(5-1500cSt) |
Temperature | Below 300°C |
Charcteristic | Double circular teeth shape,which makes the gears less wear on gear surface,stable revolution,low noise,long service life and high efficiency,due to no sliding on the teeth during gear falling in. |
Axle-end seal | Mechanical seal and packing seal |
Shipment | By sea or air |
Delivery time | 25-45 days according to order quantity |
MOQ | 1 pcs |
Package | Export standard wooden palet or user-defined |
Payment methods | TT, L/C, Western Union, Escrow |
Heat Insulation Pump PRODUCT ADVANTAGES
* Working temperature can reach 300°C
* Out standing self-priming ability
Our Heat Insulation Pump has approved GL,ABS,BV,DNV,3C,CE,ISO-9001 2000,GJ9001A-2001 etc certificate
- Q: What are the characteristics of a pipe shield pump?
- Two, reverse circulation type of shielding pump, its bearings, lubrication, cooling and motor cooling fluid flow direction and the basic type is the opposite. The main characteristic of reverse circulation pump is that it is not easy to generate cavitation. It is suitable for conveying liquid which is easy to vaporize. Sometimes it is also called "easy to vaporize" type. Three, high temperature medium temperature of up to 450 degrees. The cooling water jacket is usually added outside the shielding motor, and a cooling sleeve is added to the outer circulation pipe to cool the high temperature circulating liquid to reduce the temperature of the motor and the bearing. In the case of less power, some manufacturers do not use cooling liquid, but the outside of the motor is equipped with fins and the special winding to adapt to the working conditions, the use of temperature generally can not exceed 400 degrees.
- Q: Pump unloading in hydraulic transmission,
- Unloading water, from the literal interpretation is along the pump, leakage of water seal through the head, the water with certain pressure (even with relief effect seal). The water as the working quality is asked to be recycled, now the design of some use it as a water seal, and others by direct recovery, but eventually recovered.
- Q: What is the lift of diaphragm pump?
- Tell you: diaphragm pump head is liquid through the pump energy obtained is called lift it, and flow and pump speed, a liquid density is generally 1 kg is 10 meters lift, horizontal pipeline 10 meters 1 meters lift, a 90 degree bend is 1 meters.
- Q: Double floor sewage pump circuit diagram of a small problem
- Question 3 when the water level is low, when the 1KA is connected, the pump will run depending on where your SS selector switch is located. Its left and right position, running pump and standby pump definition is different, left position is 1#, running 2# standby, right position is 2# running, 1# standby. Only inIn case the high level switch 2KA is connected, the standby pump may work at the same time.
- Q: Difference between pump and compressor
- A pump is a machine that transports liquids or pumps liquids. It transfers mechanical energy or other external energy of the prime mover to the liquid, increasing the energy of the liquid. The pump is mainly used to transport water, oil, acid and alkali liquid, emulsion, suspension emulsion and liquid metal, and also can transport liquid, gas mixture and liquid containing suspended solid. Pump can usually be divided into three types of displacement pumps, power pumps and other types of pumps according to the principle of operation. In addition to classification according to the working principle, it can be classified and named according to other methods. For example, according to the driving method can be divided into the electric pump and the turbine pump; according to the structure can be divided into single-stage pump and multistage pump; use can be divided into the boiler feed pump and the metering pump; according to the nature of transmission fluid can be divided into water pump, oil pump and mud pump etc.. In accordance with the non axial structure, can be divided into linear pumps and traditional pumps.
- Q: What are the constant pressure pumps?
- CatalogBooster pump definitionMechanical classification, methane booster pump, pneumatic booster pumpGas-liquid booster pumpAir booster pumpChlorine booster pumpWorking principlefunctionMechanical installationMechanical selection of booster pump definitionMechanical classification, methane booster pump, pneumatic booster pumpGas-liquid booster pumpAir booster pumpChlorine booster pumpWorking principle
- Q: What is a feed pump?
- In general, high lift pumps are required with a front pump (which is similar to the feed pump of the landlord) or a low position;
- Q: What is the difference between the ground pump and the pump in the commercial concrete?
- Move back and forth; pour concrete into a certain area. After the filling is finished, the whole pump truck can be moved to another position quickly
- Q: What is the distance between the pump and the wall?
- Mainly depends on the maintenance, installation is convenient, but there is no other requirements.
- Q: No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same, how to choose the control cabinet?
- 1) microcomputer frequency conversion control cabinet2) water pump unit3) current stabilizing compensator4) vacuum suppressor5) all kinds of pipe fittings, valves and so on
Send your message to us
Gear Oil Heat Insulation Pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 5000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords