• High Viscosity Internal Gear Electric Glue Pump System 1
High Viscosity Internal Gear Electric Glue Pump

High Viscosity Internal Gear Electric Glue Pump

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
5000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Electric glue pump APPLICATION

It widely applies to a variety of mediums with different property  and viscosity because of special structure and selected different pump's materials.

Proper medium temperature: -10°C ~ 200°C

Proper medium viscosity: 1.0cSt ~ 300.000cSt

Food industry: Pumping food liuqid,wine,waste liquid or additive liquid
Textile mill: Pumping fible liquid,dyestuff,printing ink,nylon powder liquid
Paper industry: Pumping back liquor
Petro industry: Pumping oil,grease
Chemical industry: Pumping suspend liquid,emulsion,soda & salt liquid
Ship building: Pumping residue oil,sewage or seawater
Building industry: Pumping slurry,Cement
Nuclear industry: Pump rediocative liquid
Metallurgical & Mine: Pumping oxide or waste water,drain off water,liquid explosive
Watertreament: Pumping slurry,sludge,additive liquid
Power plant: Pumping coal slurry

Product nameElectric glue pump
Model number High viscosity internal gear electric glue pump
Type internal gear pump, Electric glue pump
Application scopeHigh viscosity medium,petroleum,chemical industry,paint,medicine,foodstuff and so on.
Material

1.HT200;
2.ZG230-450
3.1Cr18Ni9Ti,OCr18Ni12Mo2Ti

Capacity 0.78-1670 L/100rev
Proper medium temperature-10°C~200°C
Proper medium viscosity1.0cst-300000.0cst
CharcteristicPacking seal,especially suited to delivery high viscosity medium.  
Advantages

1.Steady delivery without pulsation,little vibration and noise.

2.out standing self-priming ability.

3.The pump can delivery the varied corrosion medium if the proper material of parts selected in addition,the working temperature can reach 200°C.

4.The same rotary direction of internal rotor and outside rotor results in little wear and long operation life.

5.The pump’s flow capacity can be changed through adjusting the speed.

6.It‘s specially suited to deliver high viscosity medium.

ShipmentBy sea or air
MOQ

1PCS

Delivery time25-45 days,according to order quality
PackageExport standard wooden palet or user-defined
Payment methodsTT,L/C,Western Union,Escrow

Electric glue pump PRODUCT ADVANTAGES


* Steady delivery without pulsation, little vibration and noise
* Working temperature can reach 200°C
* Out standing self-priming ability
* Little wear and long operation life
* Suit to deliver high viscosity medium

Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
According to the water quantity form fire flow water supply system fire safety in high-rise building fire hydrant pump lift is 10L/s, accurate algorithm is to say after a simple calculation with each indoor hydrant flow is two 5L/s bolt so to get the most unfavorable point for the calculation unit to calculate the minimum requirements, with the most unfavorable point suppository pressure specifications 0.07MPa, partial loss of the most unfavorable line and the line (according to the equivalent length) and loss (according to the material resistance coefficient), and finally the pump head loss of gravity difference. But we just calculate the construction elevation difference multiplied by 110% to 120% to determine the head {there is a need to know is: conversion head (m), (kg) and MPa kg 1MPa=10 kg = 100m is the vertical water column on unit area pressure conversion
Q: What is the minimum continuous flow of a pump?
Quality solutionsMinimum flow of pump, minimum continuous flow of pumpIn order to ensure the proper use of the pump and the normal operation of the pump manufacturer will indicate the minimum pump in the sample of the continuous operation flow, the correct selection or use to warn or instruct users. According to the provisions of the API standard, the minimum continuous flow into the minimum continuous stable flow and continuous flow. Most small thermal limit(1) the minimum continuous stable flow.API standard specifies the minimum continuous stable flow refers to the vibration limit does not exceed the standard set by the pump can work normally. The minimum flow pump at small flow rate, there will be noise and vibration increase, API of this provision is to ensure that the service life of the pump, avoid due to improper operation of the pump caused by the adverse effects.
Q: What is the dry running protector of screw pump? What's the principle and function? Thank you
The utility model relates to a screw pump dry running protector, which is used for protecting the stator and the rotor of the screw pump from being transported by air
Q: What are the functions of a disposable infusion pump?
With the development of science and technology, more and more fields need to control the flow or velocity of fluid accurately. For example, the detection and analysis of micro chemical elements in chemical industry always need to control the flow accurately. In the field of health care, the flow and velocity of traditional Chinese medicine liquid must be controlled accurately.Venous transfusion is one of the most commonly used methods of clinical treatment. It is a common medication and treatment technique for nursing specialty. Clinically, appropriate infusion rate should be applied according to the drug and patient's condition. Transfusion too fast may cause poisoning, more serious can lead to edema and heart failure;
Q: Fire control center manually start the fire pump directly, multi line control, called straight up line NHKVV-7*1.5, my understanding is: straight line from fire control center
The line between the fire pump buttons should be NHBVR-4*1.5 lines. 2 start, 2 answer. Some manufacturers reported that the 3 lines can also, this need to see which is the specific equipment. In addition, we need to introduce 2 warning buses.The above lines are individually distributed
Q: Why can't the inlet of centrifugal pump be negative pressure?
The entrance can be a negative pressure. You can often see someone pumping water from the pool. How can you pump water if it is not negative pressure?
Q: Is vane pump good or gear pump good?
1) the reversible design of gear pumps can also usually reverse, but reverse after the suction port change, and the pump safety valve does not work; leaf pump is generally not allowed to reverse. 3) the single acting vane pump can be designed to change the eccentric distance by moving the stator at the constant speed, so as to achieve the purpose of variable direction.
Q: What is the nominal pressure of the hydraulic pump and hydraulic motor?
Rated flow refers to the flow under the rated speed and rated pressure input to the motor.Due to leakage loss, the actual flow of the input motor must be greater than its theoretical flow. Actual flow of motor (i.e. inlet flow) leakage flow = theoretical flow of the motor.
Q: Which nuclear submarines use the shaftless pump technology?
Shaftless pumping technology and Simulation of shark skin technology are all the next generation of submarine propulsion technology. At present, there is no submarine in the world.
Q: How to calculate the motor power of metering pump?
Two Hydraulic power, metering pump rated flow (L/H) X, maximum pressure (Barg) / 36000 = kw