Galvanized barbed wire, IOWA, MOTTO, BWG14*14 BWG16*16 200m/250m/400m/500m for Brasil, Peru
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 5 m.t.
- Supply Capability:
- 5000 m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specification
Product Description
We are a professional wire mesh fence factory for 20 years, we have setted up complete scientific management system and advanced quality test facilities. Our main mesh products are welded mesh fence, chain link fence and hexagonal wire mesh,wire products are galvanized wire ,black annealed wire and barbed wire .Our main markets are North-America, Europe and Australia.
High quality PVC coated barbed wire with factory lower price
1.Material:low carbon iron wire,stainless steel wire and PVC coated wire
2.Wire diameter:1.0-3.5mm(before coating),1.4-4mm(after coating)
3.Weaving:single,double and reverse twist.
4.Application:
Barbed Wire been widely used by many countries in military field,railway,highway expressway, prisons, detention houses, government buildings and other national security facilities. Recently years, barbed tape has apparently become the most popular high-class fencing wire for not only military and national security applications, but also for cottage and society fence, and other private buildings.
Barbed Wire Specification | ||||
Type | Wire Gauge (SWG) | Barb Distance (cm) | Barb Length (cm) | |
Electric Galvanized | 10# x 12# | 7.5-15 | 1.5-3 | |
12# x 12# | ||||
12# x 14# | ||||
14# x 14# | ||||
14# x 16# | ||||
16# x 16# | ||||
16# x 18# | ||||
PVC coated | before coating | after coating | 7.5-15 | 1.5-3 |
1.0mm -3.5mm | 1.4mm -4.0mm | |||
BWG11#-20# | BWG8#-17# | |||
SWG11#-20# | SWG8#-17# | |||
PVC PE coating thickness: 0.4mm-0.6mm; different colors or length are available at customers request. |
FAQ
We have organized several common questions for our clients,may help you sincerely:
①How about your SA Market Hot Dipped Galvanzied Barbed Wire 10kg per Roll 1kg Per Roll?
One of the most biggest manufacturer & supplier of wires and wire mesh,is a large-scale professional UAE Market Electric Galvanised Wire BWG 20 0.7mm Hot Dipped Galvnised Wire factory in China. Annually more than 10000 tons wires and wire mesh are exported to markets all over the world. Different kinds of wires and mesh are available according to customer’s requirements.
②What is your Technical Information oft SA Market Hot Dipped Galvanzied Barbed Wire 10kg per Roll 1kg Per Roll?
1).Material: super carbon steel
2).Processing by drawing, hot-dip zinc-plating
3).Standard wire gauge from 8# to 24#
4).Thick zinc-coating layer
5).Super in corrosion resistance
6).Firm coating layer
7).Custom size available
10 to 15g Zinc Coating and 35kg Tensile Strength Iron Wire Electro Galvanized Iron Wire
③How long can we receive the product after payment?
In the purchase of Galvanized Iron Wire within three working days, We will arrange the factory delivery as soon as possible. The pacific time of receiving is related to the state and position of customers. Commonly 15 to 20 working days can be served。
SA Market Hot Dipped Galvanzied Barbed Wire 10kg per Roll 1kg Per Roll
- Q: hiI got a car radio quot;Grundig WKC 3680to stick to my car, I don't understand is the difference between : 12 VOLT BATTERY WIRE and 12 VOLT IGNITION WIRE, which one to use? I got only one cable bringing the current from my Renault 4 car!thanx
- check to see if that power lead from your car has power with the ignition off if it does that will be your memory wire and you will need to run another wire from your fuse block on an accsesory that is controlled by the ignition switch for the cd player to be able to turn on and off with the car its not a very hard job once you figure out the starting point
- Q: I am doing wiring in my shed on preexisting light fixtures and outlets. the wiring that was disconnect from that carried the electricity to it. What I am trying to do is have all the light fixtures work of an extension cord. I have another extension wire connected to that with the +, - and 0 showing. The fixtures have 3 wires coming out of them what I think to be the power in, power out, and switch. On the fixture on the end I connected my extension cord thing and it work, BUT only that one. The rest of the fixtures did not work, I do see anything wrong. What I thought was that I was connecting to the switch wire so I changed it and it just buzzed with blue light. What is going on?
- the rest of your light fixtures maybe wired through a switch. you would have to hook your extension cord to the switch but you also need to connect the common neutrals and grounds to the cord as well.
- Q: I want to connect one of my rear sony speakers along the baseboard to my receiver. The specs say that the wire comes with 4 terminal blocks, with 4 connections on each terminal. My question is what will connect to what? Will the speaker attach the the flat wire cable that will attach to the original speaker cable which will connect to the receiver? It will be much appreciated.
- The flat wire is what you run under carpets, along baseboards, etc. The four wires allow you to run a pair of speaker wires (two sets of two) from your receiver to the general location where the speakers will be. The terminal blocks allow you to run regular speaker wires from the receiver to the flat wire. The terminal block at the other end then lets you run speaker wire from a terminal block at the other end of the flat wire to the pair of speakers that wire feeds. It doesn't matter which wire goes to which speaker, as long as you wire it up correctly. That is, you can have the first terminal be the + wire for the first speaker, the second the - wire for that speaker, and the third and fourth wires being the + and - wires for the second speaker.
- Q: I am connecting a humidstat to furnace. I would normally use furnace/thermostat wire for this purpose except that I need 8 conductors and the largest furnace/thermostat wire seems to be 5 conductors. I would like to use another 18guage 8 conductor wire but not sure if there are any specifications I need to ensure it meets before I can use it inside furnace cabinet.
- they do make 8 and ten conductor stat wires but in a pinch you could run two 4 conductor wires side by side. just make sure you mark at both ends becayse you will have 2 of each color wire. mark them as red 1 and red 2, etc.
- Q: How can you make the fabric with silk fabric wrinkle free after washing?
- Hand washing machine or washing machine without special injection, dilute the product with water, and stir evenly, put into the laundry, soak for 3 minutes, remove and air.
- Q: i am going to be installing a flood light outside, i am running the wire on the outside of the house. i have down some small electrical work light outlets and switches but not sure on running wire. i was looking at lowes at outdoor wire and there are different size gauges. just wondering what size or gauge is best to use for an outdoor flood light?
- Important! You need to check the breaker size. If it is a 20Amp circuit you must use #12 or greater. If it is a 15Amp circuit #14 or greater. Wire capacity should ALWAYS be equal to or greater than the circuit breaker.
- Q: Hello, I have a 4 year old Trane XR12 unit. Recently the compressor fan is noisy, and now stops when when under power after 5-10 min. The main fuses and breakers are fine, the fan spins freely when turned, the contactor pulls in fine, the dual capacitor checks out. But, the wiring of the capacitor does not match wire diagrams. Could this have caused the fan motor to prematurely fail?..............................Terminal: C red wire, FAN brown wire, HERM has both orange and purple. Schematic shows the purple wire should be with red wire on common C. The purple also leads to fan.
- Hi, I looked at the schematic on-line. If you still have the original fan motor in the unit then you are correct. The center terminal on the capacitor should have the red wire from the T1 terminal of the contactor, the red wire from the compressor, and the purple wire from the fan. The FAN terminal should have the brown wire from the fan. The HERM terminal should have the orange wire from the compressor. The black wire from the fan and the black/blue wire from the compressor should lead back to the T2 terminal of the contactor. Again, that is if the motor is the original motor. If it was replaced at some point in time, the wiring colors can change from manufacturer to manufacturer, in which case it's possible that the new motor is wired correctly. There should be a diagram on the motor to show you the correct wiring configuration.
- Q: Wires in the dash*Radio constant*Radio Switched*Radio illumination**please match these up with the options below**Wires on the stereo itself*Dashboard Light Dimmer Switch*Amplifier Remote or Power Antenna (Positive +)*(fuze) yellow memory (negative -)*(fuze) red 12v (positive +)if someone could please help that would be great-since the wires were replaced i cant go by color
- Car radio wire constant to stereo yellow memory. Car radio wire switched to stereo red 12v positive. Car radio wire illumination to stereo Dashboard Light Dimmer Switch. Don't forget to ground the black wire on the unit to the ground wire from the car harness. An extra ground strap to the chassis is a good idea also. If you don't have an amp or a power antenna, cap off the blue Remote/Antenna wire.
- Q: Why is thin strand wire better for powering car audio?
- Hi welt needs to be multi stranded at least 8 awg in diameter as it is flexible and more flexible than a solid wire as work wire back and forth hardens copper wire and it eventually will break. using a flexible wire reduces the possibility of a breakage.
- Q: One wire has part of the plastic coating on the end, the other wire does not.
- the lead is the wires showing. lead wire can also mean attaching a wire and feed it through a wall attach other end to the wire and pull it through. Now if you need both ends to have wire showing take a utility knife firmly place wire on block of wood and lightly cut through the caseing. thats the thick wire that en cases the other wires and peal back and then cut it off. then carefully hold blade of utility knife and wire aganst your thumb on a 45 degrees away from you and pull that will strip the plastic off the wires hope that answers your question dave
Send your message to us
Galvanized barbed wire, IOWA, MOTTO, BWG14*14 BWG16*16 200m/250m/400m/500m for Brasil, Peru
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 5 m.t.
- Supply Capability:
- 5000 m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords