• Galvanized Barbed Wire (BWG12*14, BWG16*16)2.0mm Diamter Barbed Wire&ISO 9001 (XA-BW002) System 1
  • Galvanized Barbed Wire (BWG12*14, BWG16*16)2.0mm Diamter Barbed Wire&ISO 9001 (XA-BW002) System 2
  • Galvanized Barbed Wire (BWG12*14, BWG16*16)2.0mm Diamter Barbed Wire&ISO 9001 (XA-BW002) System 3
Galvanized Barbed Wire (BWG12*14, BWG16*16)2.0mm Diamter Barbed Wire&ISO 9001 (XA-BW002)

Galvanized Barbed Wire (BWG12*14, BWG16*16)2.0mm Diamter Barbed Wire&ISO 9001 (XA-BW002)

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
10 m.t.
Supply Capability:
5000 m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specification

Material:
Galvanized Iron Wire
Cross Sectional Shape:
Round
Application:
Protectiong Mesh
Type:
razor wire coil
Wild in Width:
1.1M
Surface Treatment:
zinc galvanized
Metal Wire Drawing:
Hot Drawing
Status:
Hard State
Thickness:
Metal Thick Wire
Galvanized Technique:
Hot Dipped Galvanized,Electro Galvanized

Material: High quality low carbon steel wire,Stainless steel wire,Medium carbon steel wire(Galvanized,Plastic coated,Plastic sprayed)

 

Type:double twisted barbed wire,general barbed wire,single strand barbed wire. PVC barbed wire,stoving varnish barbed wire.

Performance and Characteristic:By twisting and weaving, firm and beautiful.

 

Application: as barrier for industry,agriculture,animal husbandry,express way,tree.

 

Specification of barbed wire

Common specs:10#*10#, 12#*12#,12#*14#,14#*14#,14#*16#,16#*16#,16#*18#

 

Barbed distance:7.5--15/cm

 

Barbed length:1.5--3/cm

Galvanized Barbed Wire (BWG12*14, BWG16*16)
Galvanized Barbed Wire (BWG12*14, BWG16*16)

Specifications:

Wire Model

Length (km)

Barb Distance 3"

Barb Distance 4"

Barb Distance 5"

Barb Distance 6"

12X12

6.0617

6.7590

7.2700

7.6376

12X14

7.3335

7.9051

803015

8.5741

12-1/2X12-1/2

6.9223

7.7190

8.3022

8.7221

12-1/2X14

8.1096

8.814

9.2242

9.5620

13X13

7.9808

8.899

9.5721

10.0553

13X14

8.8448

9.6899

10.2923

10.7146

13-1/2X14

9.6079

10.6134

11.4705

11.8553

14X14

10.4569

11.6590

12.5423

13.1752

14-1/2X14-1/2

11.9875

13.3671

14.3781

15.1034

15X15

13.8927

15.4942

16.6666

17.5070

15-1/2X15-1/2

15.3491

17.1144

18.4060

19.3386

FAQ

We have organized several common questions for our clients,may help you sincerely: 

 

①How about your SA Market Hot Dipped Galvanzied Barbed Wire 10kg per Roll 1kg Per Roll?

One of the most biggest manufacturer & supplier of wires and wire mesh,is a large-scale professional UAE Market Electric Galvanised Wire BWG 20 0.7mm Hot Dipped Galvnised Wire  factory in China. Annually more than 10000 tons wires and wire mesh are exported to markets all over the world. Different kinds of wires and mesh are available according to customer’s requirements. 

 

②What is your Technical Information oft SA Market Hot Dipped Galvanzied Barbed Wire 10kg per Roll 1kg Per Roll?

1).Material: super carbon steel

2).Processing by drawing, hot-dip zinc-plating

3).Standard wire gauge from 8# to 24#

4).Thick zinc-coating layer

5).Super in corrosion resistance

6).Firm coating layer

7).Custom size available

 10 to 15g Zinc Coating and 35kg Tensile Strength Iron Wire Electro Galvanized Iron Wire

③How long can we receive the product after payment?

In the purchase of Galvanized Iron Wire within three working days, We will arrange the factory delivery as soon as possible. The pacific time of receiving is related to the state and position of customers. Commonly 15 to 20 working days can be served。

SA Market Hot Dipped Galvanzied Barbed Wire 10kg per Roll 1kg Per Roll

 

Q: What are the basic characteristics of wire resistance strain gages?
A resistor that is not to be changed is called a fixed resistor. Variable resistance is called a potentiometer or variable resistor. The ideal resistor is linear, i.e., the instantaneous current through the resistor is directly proportional to the applied instantaneous voltage. Variable resistor for partial pressure. One or two removable metal contacts are tightly pressed on exposed resistors. The contact position determines the resistance between any end of the resistor and the contact point.
Q: Hi,I have an issue with wiring in house. This is in Paris, France. I will share a foto so you can have a clearer picture what my question is.
Got a meter? On the output side Wht/Grn = ground Brown = 'Hot' (230 V.) Blue = Neutral Test out what you've got in the French outlet box.
Q: ive heard multiple people talk about a 'final wire'. what is it exactly? Is it the thickest wire possible? Or is it when you havent gotten your wire changed in a while?
The final wire is, as its name implies, the very last wire that will be used before your braces comes off. It is usually either a square or rectangular wire and braided. The wire is used to do the final tweaking on your teeth and to close any minor gaps you may still have. And YES, it is the thickest wire you will wear.
Q: Two current carrying wires are perpendicular to each other.Wire 1 is placed on top of wire 2.Wire 1 current direction is pointing North, wire 2 current direction is pointing east. Is there a force on either of the two wires?Does one wire spin due to the produced force?Please explain to me how to do this questionThanks
Take your right hand and point its thumb to the North representing conventional current flow (Plus to Minus) in the top wire. Visualize the curl of your right hand's fingers can now be replaced be visualizing a bike tire rotating from nuckles to fingernail. Now do the same with the wire having current going East. Contact the two bike tires together a some infinitesimal spot. If those tires are exactly perpendicular in the X and Y (Z doesn't seem to matter because it is the point where they touch), it would make sense to predict that on top a vector will point West and on the bottom a vector will point South. The net vector should be SW. So, if you marked the initial point of cross over on the wires and mechanically could keep them free to move but still perpendicular, the cross over point would move SW for as long as equal current flowed in the two wires.
Q: trying to find the radio wiring diagram for my suburban to find out where all my speaker wires are .
1994 Chevrolet Suburban Car Stereo Radio Wiring Diagram Radio Constant 12V+ Wire: Orange Radio Ignition Switched 12V+ Wire: Yellow Radio Ground Wire: Black Radio Illumination Wire: Gray Radio Dimmer Wire: Brown Radio Antenna Trigger Wire: N/A Radio Amplifier Trigger Wire: N/A Front Speakers Size: 6 1/2″ Speakers Front Speakers Location: Doors Left Front Speaker Wire (+): Tan Left Front Speaker Wire (-): Gray Right Front Speaker Wire (+): Light Green Right Front Speaker Wire (-): Dark Green Rear Speakers Size: 6 1/2″ Speakers Rear Speakers Location: Rear Doors Left Rear Speaker Wire (+): Brown Left Rear Speaker Wire (-): Yellow Right Rear Speaker Wire (+): Dark Blue Right Rear Speaker Wire (-): Light Blue
Q: On a seat switch on a poulan mower it has three wires are two of them grounds or one.
It's probably one positive, one negative and one earth ground.
Q: i just got guitar hero 3 and i want to buy another guitar contoller for the xbox 360 but my mom only wants to buy the wired one because it is cheaper is there anything wrong with the wired one and should i get it or not since i will be playing it with my brother. also how long will the wire be.
OK don't laff. i have gh3 and a wired and a wireless guitar. the cord is about 6 feet long and it is ok. there is nothing worse than being about half way through a song and your 360 says please reconnect controller. go for the wired and rock on!
Q: I have a 200 amp main breaker just below my meter, which is mounted on a pole. The neutral wire coming in is run to ground. From this box, I've run 2 cables (1/0) ~80 ft to another box with a 150 amp main breaker. This box is grounded to an 8ft ground rod. I am wondering whether this setup (no neutral wire from meter pole to building) would potentially allow a ground fault without tripping the 200 amp main. For example, if somebody dug into the line with a backhoe? Oh yeah, the cable is in a 3ft deep trench that will be covered. I have an abridged version of the NEC, but I haven't found this particular topic covered. Thanks.
Good job, Amy. I'll bet you didn't post a question here similar to: Waz the difference between nuetral and ground. I nned to now this for my electian exam tomorow.
Q: Will you please remove any of the wires? The edge of the body, which is made of wire or what? Is it copper or iron?
Residential electrical wiring generally uses only one layer of plastic insulated copper core wire, which is usually worn in plastic pipes or steel tubes, concealed in the wall, in order to avoid mechanical damage. Conductor part of the conductor in the structure of solid and twisted two kinds, and its components are pure metal, alloy, coating and enameled wire. (referring to the Baidu encyclopedia wire structure) metals cannot ignite, and copper has a melting point of more than 1000 degrees! No electricity, no electricity, of course. Does not rub with wood to produce electricity or sparks.
Q: I have a 220v single phase kiln with two red wires labeled L1 and L2, and one white wire labeled N. It did not come with the plug, so I bought one and new wire 3/c 10awg, but it has ground(green), Hot(black), and neutral(White). I dont know how to proceed with wiring? any help would be great. Thanks. Jose
Wire L1 L2 to the spade looking terminals, and the n to the round pin.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches