• Galvanized Razor Barbed Wire / Barbed Wire Bto-22 System 1
  • Galvanized Razor Barbed Wire / Barbed Wire Bto-22 System 2
  • Galvanized Razor Barbed Wire / Barbed Wire Bto-22 System 3
Galvanized Razor Barbed Wire / Barbed Wire Bto-22

Galvanized Razor Barbed Wire / Barbed Wire Bto-22

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
5 m.t.
Supply Capability:
5000 m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specification

Material:
Stainless Steel Wire,Galvanized Iron Wire
Cross Sectional Shape:
Round
Application:
Protectiong Mesh,Fence Mesh
Type:
Steel Coll,Galvanized
Wild in Width:
1.1M
Surface Treatment:
galvanized
Metal Wire Drawing:
Hot Drawing
Status:
Hard State
Thickness:
Metal Thick Wire
Galvanized Technique:
Hot Dipped Galvanized,Electro Galvanized

Product Description

Galvanized razor barbed wire / barbed wire 

Galvanized Razor Barbed Wire / Barbed Wire

1. Razor barbed wire and barbed wire can both be supplied.

2. Factory certificate: ISO9001:2000; SGS; CE; BV; etc

3. Regular specification of razor barbed wire:

Blade Specification

Blade Forms

Blade Thickness

Core Wire Dia.

Blade Length

Blade Width

Blade Space

BTO-10


0.5±0.05

2.5±0.1

10±1

13±1

26±1

BTO-12


0.5±0.05

2.5±0.1

12±1

15±1

26±1

BTO-18


0.5±0.05

2.5±0.1

18±1

15±1

33±1

BTO-22


0.5±0.05

2.5±0.1

22±1

15±1

34±1

BTO-28


0.5±0.05

2.5

28

15

45±1

BTO-30


0.5±0.05

2.5

30

18

45±1

CBT-60


0.6±0.05

2.5±0.1

60±2

32±1

100±2

CBT-65


0.6±0.05

2.5±0.1

65±2

21±1

100±2



Ex. Dia.

No. of Turns

Standard Covering Length

Production Model

Remarks

450mm

33

8M

CBT-65

Single coil

500mm

41

10M

CBT-65

Single coil

700mm

41

10M

CBT-65

Single coil

960mm

53

13M

CBT-65

Single coil

500mm

102

16M

BTO-12.18.22

Cross type

600mm

86

14M

BTO-12.18.22

Cross type

700mm

72

12M

BTO-12.18.22

Cross type

800mm

64

10M

BTO-12.18.22

Cross type

960mm

52

9M

BTO-12.18.22

Cross type

 
4. Package of razor barbed wire:
 Wrapped with plastic cloth inside, plastic woven bag outside. Every 20 bundles are wrapped with steel strip, into one large bundle.

5. Barbed wire can also supplied, pls see specification as following:

Barb wire
Material:Galvanized steel wire, PVC coated iron wire
Application:Protecting of military, industry, agriculture, animal husbandry, dwelling house, plantation or fencing.
Product Features:Anti-aging, Corrosion resistance, Protective Ability
Corrosion form:PVC coated, plastic coated, electric galvanized and hot dipped galvanized
Weaving types:Single twist barbed wire and double twist barbed wire, Reverse twisted and continuous twisted.
Package:In coil of 25 kilos or 50 kilos net, lined with P.V.C strips, then wrapped with P.V.C or hessian cloth.
Specification:
TypeWire Gauge (SWG)Barb   Distance (cm)Barb   Length (cm)Electric Galvanized Barbed Wire; Hot-dip zinc plating  barbed wire10# x 12#7.5-151.5-312# x 12#12# x 14#14# x 14#14# x 16#16# x 16#16# x 18#PVC coated barbed wire; PE barbed wirebefore coatingafter coating7.5-151.5-31.0mm-3.5mm1.4mm-4.0mmBWG11#-20#BWG8#-17#SWG11#-20#SWG8#-17#PVC PE coating thickness: 0.4mm-0.6mm; different colors or length are available at customers request



Galvanized Razor Barbed Wire / Barbed Wire
6. Application:
Razor Barbed Wire is widely used in military affairs, prison, government, bank, and also in living wall, personal house, villatic wall, window, autobahn, railway and border of the fence.

Galvanized Razor Barbed Wire / Barbed Wire


Q:Broken dryer, 4 bladed wire, Old dryer available to me, has a 3 wire cord, can I swap the cords?
the guidelines basically recently replaced interior the previous couple of years requiring new properties to be geared up with the 4 prong recepticals rather than the three prong recepticals for 220 V merchants. in the experience that your dryer is fantastically new, interior the final 4 years or so... the twine that is hooked as much because it now could have the skill to be interchanged with a 4 prong twine by basically buyingh a 4 prong twine and screwing the eylets to the surprising connections at the back of your dryer. in the experience that your twine won't be able to be switched out, then i'd pass backward and replace the 4 prong container with a three prong container. i'd do it this sort so as that one and all your electric connections are interior a receptical, rather of having 220 Volt wires basically twine nuted at the same time.ok good success.
Q:The t-stat comes with EIT module. that wires to the t-stat and the furnace. I'm having trouble with the module to furnace wiring.
from the thermostat you match 1,2,3 wires to the module, from the module to the furnace. - R to R (this is your 24V hot) W to W (furnace 24V input G to G (fan for cooling 24V input) Y to Y (cooling 24V input), there should also be another wire that connects with this that goes to the condensing unit C to C ( Common - must have this connected for IAQ to work) as with the Y, there should be another wire to connect to this that goes to the condensing unit. - maybe W2 to W2 if you have a 2 stage furnace, you'll know if you have a 2 stage furnace because the W2 connection on the furnace will be present. - maybe Y2, if you have 2-stage cooling. if you have a humidifier connect both wires from the humidifier selinoid valve to each of the HUM terminals.
Q:Replaced the old fan in my bathroom (about 10 years old) with a new fan. Trouble is this. The fan and light each work on a seperate bathroom switch. I have two spots to install the wire on the new bathroom fan/light. One for the fan and one for the ligth. However, the wiring has one white, one black, one red and the ground. Anyone know what the red is? Can I just cap it off? According the bathroom fan wiring it says something about connecting red to blue. I am slighty confused. I think it was originally only wired between the white and black. I am not sure if I have to get some extra wire and connect the black and red to the light and the white to the fan? Extra wire is confusing.
the black is one switch leg and the red is the other switch leg connect black to fan and red to light and ground the green or bare wire it will work just fine and connect white to white neutral
Q:So I need to tap a few wires, and cut 1 wire and join it with another wire..What would be the best way to approach this? Here are the full instructions so you guys have an idea on what I'm trying to do.quot;On the TAN plug there is 1 ALL PINK(E7) wire you need attach the WHITE wire from your relay to that but don't cut the PINK wire just tap the WHITE into it.Next go the the GREY BCM plug there are 3 WHITE wires.
The instructions seem pretty straight-forward. T-Taps and squeeze-connectors are basically the same thing; achieving the same results, which is to add a connection to an existing wire without interrupting the line. Just make sure you use the right size and type, meaning; don't use a low-voltage connector for a high-voltage application... You'd just fry it up. For the cut wires, I'd use crimp-connectors and some shrink-wrap. Again, using the correct connector. You can use wire-nuts, but the crimp-connectors are a more permanent fix. Good luck to ya.
Q:While updating the parents basement we needed to replace a very very old 3 way switch. However, the wiring to the Fluorescents seems extreme to me. Here is how i can describle the layout. Panel - junction box - double splice (one to light fixture and one to threeway switch below it)-. From that threeway switch 12-3 wiring to upstairs landing with other threeway switch resides. How should I make my connections to switches? If the other swtiches were not so old I would just copy them.
Hi its looks as if you bought the wrong switch,if it fits try connecting the black to black,and white to white,tape off the red it should work,if not black to black and red to white,you cant blow anything but it may run without switching on,just be careful and turn of fan fuse switch at mains All the best John UK I now see your extra Information ,your fan will not work unless you connect the supply to your fan is connected,you need a permanent supply [live] and a switched supply [live] and a neutral all three cables go into timer and out of timer two connections to the black and white cables.the timer SWITCH should be marked L--N--S L =live incoming N =neutral S =switched live,---S=White N=black I hope that's this is enough Information John UK
Q:when we connect the amp wire to the car battery we first remove the negative side then connect the amp wire to the negative side and reconnect the negative battery wire thing. is this correct?
This Site Might Help You. RE: connect amp wire to car battery? when we connect the amp wire to the car battery we first remove the negative side then connect the amp wire to the negative side and reconnect the negative battery wire thing. is this correct?
Q:Or speaker wire that has an RCA plug on one end?If you know of something that is inexpensive without me having to get another preamp, please help.(this is for a turntable preamp by the way, my preamp only has RCA output.)
do not use speaker wire for the turntable preamp!! use RCA cables. speaker wire is balanced wire, both conductors are identical. RCA connectorized wire is coaxial, shielded and unbalanced. You need the shielded coaxial unbalanced wire.
Q:Us the French wire hook earrings gold? 14kt gold?!?
French wire earrings are a style of earrings for pierced ears. They have a long hook shape. They can come in gold or silver or any metal. The style isn't an indication of its metal content. If they are 14k gold, they will need to be stamped as such and you should buy them from a reputable jeweller. Online buying can be a problem, they are people who fake the gold markings (especially goods from Asian countries) and you might think you are getting real gold, but you aren't. Also, sometimes only the wire hook part is gold, the attachment or dangle might be an alloy metal and not gold at all.
Q:Need ro know where to put the wires correctly
the terminals are colour coded, green for the green or ground wire, brass coloured for the live wires ( the red and black ones) and silver for the white wire.. make sure the power is off!!! it only takes 40 volts a 60 hz AC to KILL! look close for GRN for ground and green, LOAD or LINE for the black or red wires and further for NEUTRAL, ( N) or Neut. for the white wire...YOU CAN CHECK FOR POWER WITH PIGTAIL white to white and black to either black or white one at a time...post again so we know if your alive...
Q:i would like to know what are the best spark plug wires
just dont get the cheapest wires they wont last as long

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords