General of High Voltage 11KV Variable Frequency Drive
High Voltage 11KV Variable Frequency Drive is designed to be highly reliable with high-performance, yet easy to use.It can satisfy users' need for changing the speed of fans or pumps,as well as improve the productivity.
The series are compatible with all types of three-phase medium voltage asynchronous motors.
Application Filed of High Voltage 11KV Variable Frequency Drive
High Voltage 11KV Variable Frequency Drive can usually be applied in these fields:
Power generation: induced draft fans, forced draft fans, condensate exhausting pump, boiler feed water pumps, primary fan, secondary fan, circulating pump, mill fan, slurry pump, mill .
Metals: dusting fans, slurry pump, feeding pump, furnace fans, compressor, mill
Cement: fan, discharge fan, waste gas fan, dust collecting fan, dust removing fan, mill.
Oil & Gas: water injection pump, oil transfer pumps, air compressor.
Mining: Fans, media pump, circulating pump, gas pump, oil separating pump, compressor, lift, mill, conveyer, hoisting machine.
Water: water supply pump, circulating pump.
System Principle of High Voltage 11KV Variable Frequency Drive
Technology Data of High Voltage 11KV Variable Frequency Drive
3KV series Variable Frequency Drive
Model |
A03/050~A03/100 |
A03/100~A03/175 |
A03/175 ~A03/220 |
A03/220~A03/400 |
A03/220~A03/610 |
Capacity(kVA) |
250~630 |
630~900 |
900~1150 |
1150~2000 |
2000~3125 |
Rated output current (A) |
50~100 |
100~175 |
175~220 |
220~400 |
400~610 |
Motor power (kW) |
200~400 |
400~710 |
710~900 |
900~1600 |
1600~2500 |
Input frequency |
45Hz~55Hz | ||||
Rted input voltage |
3000V±10% | ||||
Input power factor |
0.95 (>20%load) | ||||
Efficiency |
0.96 with rated load | ||||
Output frequency |
0.5Hz~120Hz | ||||
Frequency resolution |
0.01Hz | ||||
Overload capacity |
120% 1 min, 150% immediately | ||||
Analogue input |
0~10V/4~20mA | ||||
Analogue output |
0~10V/4~20mA | ||||
Acceleration/deceleration time |
0.1~3000s | ||||
Digital output/input |
expanded according to requirement | ||||
Ambience temperature |
0~40℃ | ||||
Storage/transport temperature |
-40~70℃ | ||||
Cooling |
air cooling | ||||
Ambience humidity |
<90% without condensation | ||||
Altitude |
<1000 m | ||||
IP class |
IP20 | ||||
Size(mm)(W×H×D) |
3300×2480×1200 3900×2480×1200 |
4900×2480×1200 6000×2580×1200 |
6000×2580×1300 | ||
Weight (kg) |
3000 ~5000 |
5000 ~7300 |
7300~9200 |
6KV series Variable Frequency Drive
Model |
A06/050 |
A06/050~A06/080 |
A06/080~A06/100 |
A06/100~A06/170 |
A06/170~ A06/220 |
A06/220~A06/400 |
A06/400~A06/610 |
Capacity(kVA) |
≤500 |
500~800 |
800~1000 |
1000~1750 |
1750~2250 |
2250~4000 |
4000~6250 |
Rated output current (A) |
≤50 |
50~80 |
80~100 |
100~170 |
170~220 |
220~400 |
400~610 |
Motor power (kW) |
≤400 |
400~630 |
630~800 |
800~1400 |
1400~1800 |
1800~3250 |
3250~5000 |
Input frequency |
45Hz~55Hz | ||||||
Rated input voltage |
6000V±10% | ||||||
Power factor |
0.95(>20%load) | ||||||
Efficiency |
0.96with rated load | ||||||
Output frequency |
0.5Hz~120Hz | ||||||
Frequency resolution |
0.01Hz | ||||||
Overload capacity |
120% 1 min, 150% immediately | ||||||
Analogue input |
0~10V/4~20mA | ||||||
Analogue output |
0~10V/4~20mA | ||||||
Acceleration/deceleration time |
0.1~3000s | ||||||
Digital input/output |
expanded according to requirement | ||||||
Ambience temperature |
0~40℃ | ||||||
Storage/transport temperature |
-40~70℃ | ||||||
Cooling |
air cooling | ||||||
Ambience humidity |
<90%,without condensation | ||||||
Altitude |
<1000m | ||||||
IP class |
IP20 | ||||||
Size(mm)(W×H×D) |
3600×2480×1200 ,TD> |
3900×2480×1200 |
4200×2480×1200 5100×2480×1200 |
5200×2580×1200 |
6600×2580×1300 8700×2780×1400 | ||
Weight (kg) |
3500~4000 |
4000~5000 |
5000~6000 |
6000~8000 |
8000~14000 |
10KV series Variable Frequency Drive
Model |
A10/080 |
A10/080~A10/150 |
A10/150~A10/210 |
A10/210~A10/400 |
Capacity(kVA) |
≤1250 |
1250~2500 |
2500~3500 |
3500~6250 |
Rated output current (A) |
≤80Rated output current (A) |
80~150 |
150~210 |
210~400 |
Motor power(kW) |
≤1000 |
1000~2000 |
2000~2800 |
2800~5000 |
Input frequency |
45Hz~55Hz | |||
Rated input voltage |
10000V±10% | |||
Power factor |
0.95(>20%load) | |||
Efficiency |
0.96with rated load | |||
Output frequency |
0.5Hz~120Hz | |||
Frequency resolution |
0.01Hz | |||
Overload capacity |
120% 1 min, 150% immediately | |||
Analogue input |
0~10V/4~20mA | |||
Analogue output |
0~10V/4~20mA | |||
Acceleration/deceleration time |
0.1~3000s | |||
Digital input/output |
expanded according to requirement | |||
Ambience temperature |
0~40℃ | |||
Storage/transport temperature |
-40~70℃ | |||
Cooling |
air cooling | |||
Ambience humidity |
<90%,without condensation | |||
Altitude |
<1000m | |||
IP class |
IP20 | |||
Size(mm)(W×H×D) |
4500×2480×1200 |
5700×2480×1200 |
6800×2580×1300 |
10600×2580×1300 |
Weight(kg) |
3500~6000 |
6000~8000 |
8000~15000 |
15000~19000 |
- Q: How do I protect the inverter when the three-phase two-pole motor is running?
- A: At this time to put the heart in the stomach, wait and see the change, what do not move (to prevent the accident to expand), until the motor stops, and then confirm, what kind of protection: alarm (alarm automatically after the release) or failure , Such as: over-voltage, overload, over-temperature, etc., and then the right medicine; inverter in the run which is not allowed, forced parking stop. Otherwise it will cause serious damage to the inverter.
- Q: Laptop power adapter (no power supply, but indicator light)
- There may be reasons for the power adapter, there may be a computer can not identify the power supply is battery-powered or AC power. These are just speculated by your phenomenon, if you are better in the warranty period to the customer service test, so the best
- Q: Huichuan frequency converter drag a 4-kilowatt four-pole motor to change the six pole can?
- Change 6 will only be slower, the fan is no longer role. The frequency converter has a power parameter, as long as the motor is less than or equal to this power can be.
- Q: Can the HP laptop's power adapter be universal?
- If the power adapter socket is the same as the output voltage can be common. But there are a few places to note, HP notebook power adapter output voltage there are many, the most common 19V and 18.5V, but even if the output voltage is the same, the output current may be different, that is, the output power is not the same , If your notebook needs a larger input power, then you have to use the match can be, the lower power may not make the battery normal use, and even harmful to the battery.
- Q: On the laptop power adapter problem
- Notebook power on the two specifications, one is 65W, one is 40W, 65W power supply is a discrete graphics notebook, 40W is integrated graphics notebook. Just connected to the use of power, then there is no problem. Just if you laptop battery with the light of the words, plug in the power can not be the same as with the 65W, immediately you can use the boot. Because the current is low, the charging speed is relatively slow. The other will not have any effect
- Q: Short-term short-circuit converter DC link positive and negative will damage the inverter?
- the switch signal Is the fan running up after the speed line is low, this can be shorted. Pulse is every turn a circle, send two pulses to the speed line
- Q: 22kw.2 pole fan can use Fuji inverter?
- according to the rated name of the fan brand and the inverter rated current control, select the current value match, or slightly larger The
- Q: Oil-free vertical vacuum pump why a little negative pressure inverter on the torque limit
- and then use the inverter into three-phase AC, 380 volts almost, Can only use the transformer rose to 380 volts.
- Q: Three motors, if coupled with the governor speed, is it necessary to add the inverter?
- ?Second, the variable speed: change the way the stator winding wiring to change the cage motor stator pole pairs to speed.
- Q: Three sets of batteries (540V) DC power supply U / f inverter.
- It is estimated that the battery should be string - and - series connection method, and then rectifier part of the converter (which may also be caused by the switch) is actually a series of diodes in series, positive and negative after the reverse is actually the battery is Negative shorts, resulting in burning, as to burn only one of the group of a few cells, it should be string - and - string and that group, because the parallel to bear it double voltage.
1. Manufacturer Overview
Location | Beijing,China |
Year Established | 1998 |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | TIANJIN |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | ENGLISH,CHINESE |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
High Voltage 11KV Variable Frequency Drive
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1PC pc
- Supply Capability:
- 10,000pc/year pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords