High Voltage 11KV Variable Frequency Drive
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1PC pc
- Supply Capability:
- 10,000pc/year pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
General of High Voltage 11KV Variable Frequency Drive
High Voltage 11KV Variable Frequency Drive is designed to be highly reliable with high-performance, yet easy to use.It can satisfy users' need for changing the speed of fans or pumps,as well as improve the productivity.
The series are compatible with all types of three-phase medium voltage asynchronous motors.
Application Filed of High Voltage 11KV Variable Frequency Drive
High Voltage 11KV Variable Frequency Drive can usually be applied in these fields:
Power generation: induced draft fans, forced draft fans, condensate exhausting pump, boiler feed water pumps, primary fan, secondary fan, circulating pump, mill fan, slurry pump, mill .
Metals: dusting fans, slurry pump, feeding pump, furnace fans, compressor, mill
Cement: fan, discharge fan, waste gas fan, dust collecting fan, dust removing fan, mill.
Oil & Gas: water injection pump, oil transfer pumps, air compressor.
Mining: Fans, media pump, circulating pump, gas pump, oil separating pump, compressor, lift, mill, conveyer, hoisting machine.
Water: water supply pump, circulating pump.
System Principle of High Voltage 11KV Variable Frequency Drive
Technology Data of High Voltage 11KV Variable Frequency Drive
3KV series Variable Frequency Drive
Model |
A03/050~A03/100 |
A03/100~A03/175 |
A03/175 ~A03/220 |
A03/220~A03/400 |
A03/220~A03/610 |
Capacity(kVA) |
250~630 |
630~900 |
900~1150 |
1150~2000 |
2000~3125 |
Rated output current (A) |
50~100 |
100~175 |
175~220 |
220~400 |
400~610 |
Motor power (kW) |
200~400 |
400~710 |
710~900 |
900~1600 |
1600~2500 |
Input frequency |
45Hz~55Hz | ||||
Rted input voltage |
3000V±10% | ||||
Input power factor |
0.95 (>20%load) | ||||
Efficiency |
0.96 with rated load | ||||
Output frequency |
0.5Hz~120Hz | ||||
Frequency resolution |
0.01Hz | ||||
Overload capacity |
120% 1 min, 150% immediately | ||||
Analogue input |
0~10V/4~20mA | ||||
Analogue output |
0~10V/4~20mA | ||||
Acceleration/deceleration time |
0.1~3000s | ||||
Digital output/input |
expanded according to requirement | ||||
Ambience temperature |
0~40℃ | ||||
Storage/transport temperature |
-40~70℃ | ||||
Cooling |
air cooling | ||||
Ambience humidity |
<90% without condensation | ||||
Altitude |
<1000 m | ||||
IP class |
IP20 | ||||
Size(mm)(W×H×D) |
3300×2480×1200 3900×2480×1200 |
4900×2480×1200 6000×2580×1200 |
6000×2580×1300 | ||
Weight (kg) |
3000 ~5000 |
5000 ~7300 |
7300~9200 |
6KV series Variable Frequency Drive
Model |
A06/050 |
A06/050~A06/080 |
A06/080~A06/100 |
A06/100~A06/170 |
A06/170~ A06/220 |
A06/220~A06/400 |
A06/400~A06/610 |
Capacity(kVA) |
≤500 |
500~800 |
800~1000 |
1000~1750 |
1750~2250 |
2250~4000 |
4000~6250 |
Rated output current (A) |
≤50 |
50~80 |
80~100 |
100~170 |
170~220 |
220~400 |
400~610 |
Motor power (kW) |
≤400 |
400~630 |
630~800 |
800~1400 |
1400~1800 |
1800~3250 |
3250~5000 |
Input frequency |
45Hz~55Hz | ||||||
Rated input voltage |
6000V±10% | ||||||
Power factor |
0.95(>20%load) | ||||||
Efficiency |
0.96with rated load | ||||||
Output frequency |
0.5Hz~120Hz | ||||||
Frequency resolution |
0.01Hz | ||||||
Overload capacity |
120% 1 min, 150% immediately | ||||||
Analogue input |
0~10V/4~20mA | ||||||
Analogue output |
0~10V/4~20mA | ||||||
Acceleration/deceleration time |
0.1~3000s | ||||||
Digital input/output |
expanded according to requirement | ||||||
Ambience temperature |
0~40℃ | ||||||
Storage/transport temperature |
-40~70℃ | ||||||
Cooling |
air cooling | ||||||
Ambience humidity |
<90%,without condensation | ||||||
Altitude |
<1000m | ||||||
IP class |
IP20 | ||||||
Size(mm)(W×H×D) |
3600×2480×1200 ,TD> |
3900×2480×1200 |
4200×2480×1200 5100×2480×1200 |
5200×2580×1200 |
6600×2580×1300 8700×2780×1400 | ||
Weight (kg) |
3500~4000 |
4000~5000 |
5000~6000 |
6000~8000 |
8000~14000 |
10KV series Variable Frequency Drive
Model |
A10/080 |
A10/080~A10/150 |
A10/150~A10/210 |
A10/210~A10/400 |
Capacity(kVA) |
≤1250 |
1250~2500 |
2500~3500 |
3500~6250 |
Rated output current (A) |
≤80Rated output current (A) |
80~150 |
150~210 |
210~400 |
Motor power(kW) |
≤1000 |
1000~2000 |
2000~2800 |
2800~5000 |
Input frequency |
45Hz~55Hz | |||
Rated input voltage |
10000V±10% | |||
Power factor |
0.95(>20%load) | |||
Efficiency |
0.96with rated load | |||
Output frequency |
0.5Hz~120Hz | |||
Frequency resolution |
0.01Hz | |||
Overload capacity |
120% 1 min, 150% immediately | |||
Analogue input |
0~10V/4~20mA | |||
Analogue output |
0~10V/4~20mA | |||
Acceleration/deceleration time |
0.1~3000s | |||
Digital input/output |
expanded according to requirement | |||
Ambience temperature |
0~40℃ | |||
Storage/transport temperature |
-40~70℃ | |||
Cooling |
air cooling | |||
Ambience humidity |
<90%,without condensation | |||
Altitude |
<1000m | |||
IP class |
IP20 | |||
Size(mm)(W×H×D) |
4500×2480×1200 |
5700×2480×1200 |
6800×2580×1300 |
10600×2580×1300 |
Weight(kg) |
3500~6000 |
6000~8000 |
8000~15000 |
15000~19000 |
- Q: How to choose the right inverter?
- Inverter selection science or not for the normal operation of the frequency conversion system is essential. Many beginners on the general inverter selection method is not enough understanding, or even know the method, not sure the choice of the inverter model is positive solution, the following for everyone to solve the mystery. Inverter selection first look at the AC motor. Because the frequency conversion system generally first determine the motor, then select the inverter. In principle, it is necessary to determine the inverter model based on the actual current at which the AC motor is operating for a long time, and not on the motor nameplate. Inverter selection next depends on the load type. Frequency conversion system driven load equipment can be divided into three types: constant torque load, constant power load, fan, pump load, different load type select the inverter model is different.
- Q: Laptop adapter
- The first of the power to be large, not recommended to use the second to replace the other 90W adapter size are similar, but if the computer is not installed when the battery, 65W can also be used, as long as the interface on the Oh
- Q: Is it possible to use a different laptop's power adapter?
- See the adapter is suitable for notebook models to use, the following three conditions for reference: 1. The output voltage of the adapter is the same as that of the notebook. 2. Is the adapter's output current consistent with the notebook's requirements? (Or a little bit of the current is also not.) 3. The size of the joint is appropriate. (If the connector is too loose, will be bad, excessive fever.) For DELL and HP / Compaq and other notebook power adapter, will involve a decoding problem. Please pay attention when the pro to buy. It is said that the market is also very popular universal adapter, a friend bought a LVSUN brand universal adapter LS-PAB90-BC10, with eight joints. Adapter has a liquid crystal display, you can automatically switch the voltage, very smart, with more than a year, has also been used
- Q: Can the laptop power adapter be generic?
- Not necessarily, the laptop power adapter has two interfaces for input and output. 1. Input interface is connected to the power outlet, generally divided into two holes and three holes, as well as round mouth and flat mouth of the points; 2. Output interface is connected to the computer side, size, length, diameter, diameter, the pin may have differences, common are: diameter 2.5MM, ordinary mouth, mainstream interface; OD 1.7MM, small mouth; MM, big mouth with a needle, round mouth with a needle and so on. 3. Different voltage, different brands of laptop power adapter voltage is not the same 4. Current is different, different brands of notebook computer power adapter current is not the same In summary, the laptop power adapter between the different types, basically not common
- Q: I have a 5.5 kilowatts of 4-pole motor, want to pass through the inverter, slow down to 130 per minute use, eliminating the need for speed,
- Second, the use of low-speed inverter motor. Ordinary motor running for a long time, heat is certainly not work.
- Q: On the notebook power adapter output current and voltage issues
- On the real virtual cable that adapter is rectifier filter output, no regulator, the notebook internal regulator, the adapter does not need to regulator. 3.25A is smaller than 4.5A, because the adapter has a power margin that can be used. Summer attention to touch the adapter surface is overheating. Conditional or buy a large number of good current.
- Q: Can the notebook's power adapter be mixed?
- At present, the market sales of notebook power is generally 90 watts and 65 watts two, using integrated graphics, or configure the low-end notebook, usually 65 watts. Using the independence was, the configuration of high-end, or the game audio and video of this, are generally 90 watts. If the laptop's power adapter is damaged can not be used, it is best to repair the department as soon as possible to repair. If it is for emergency, before using the two adapters to check the output power and current and voltage are conceded, as the adapter input current and voltage is not the same, should be the general household voltage is 220V, so almost all of the notebook power The adapter is 100-240V ~ 1.5A words, as long as the output current and voltage values, and wattage equal, and then one is the same interface, you can mix. In general, the voltage is stable, the output wattage is the same, the notebook is basically no harm.
- Q: How to lift Yaskawa inverter base blockade?
- Note: the base blockade is to deal with ul or ce such a special application of security agencies, meaning that when the parking limit action after the base blockade even if the program can not malfunction, relative to the emergency stop loop more harsh, they will directly cut off the power power supply. In fact, it is a white protection function, if we are not difficult to find the analysis, when over-voltage or undercurrent, the panel will show BB alarm, BB is the base block, is the base blockade.
- Q: Is the motor having a variable frequency motor and a variable voltage motor?
- Motor with DC and AC motor, variable frequency motor and fixed frequency motor, string motor, that is, I have not heard of a transformer motor.
- Q: Who knows how the inverter is calculated?
- There is no pole in the inverter, the electrode can be polarized, the greater the number of poles of the motor the slower the speed, please refer to.
1. Manufacturer Overview
Location | Beijing,China |
Year Established | 1998 |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | TIANJIN |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | ENGLISH,CHINESE |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
High Voltage 11KV Variable Frequency Drive
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1PC pc
- Supply Capability:
- 10,000pc/year pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords