Technical specifications
Table 2.3: Technical Parameters of QD200 Series Frequency Inverters
ITEM | SPECIFICATIONS | |
Main Input | Rated voltage and frequency | Single-phase 200V class: 200V-240V,50Hz/60Hz |
3-phase 400V class: 380V-480V , 50Hz/60Hz | ||
Allowable value of change | Voltage: 380V-15% ~ 480V+10%; Frequency: ±15% | |
Main output | Output voltage | Maximum output voltage equals to input voltage |
Output frequency | 0.5 Hz to 400 Hz | |
Overload capacity | 150% of rated output current for 60s, 200% of rated output current for 2s | |
Control performance | Modulation mode | 3-phase PWM, 2-phase PWM |
Control mode | V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving | |
Setting method of run command | Outer terminal, keyboard panel or serial communication | |
Setting method of speed command | Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal | |
Speed setting resolution | Keyboard: 0.1 Hz | |
Analog setting: 0.05/50Hz (10bit) | ||
Speed control precision | V/f control:±2% | |
vector control without PG (open loop control): ±0.2% | ||
Speed control range | V/f control 1:40 | |
vector control without PG (open loop control) 1:200 | ||
Acceleration and Deceleration Time | 0-3200.0s | |
switching frequency | 1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency | |
Analog input | Number | 2 ways: AI1、AI2 |
Type | DC voltage or DC current | |
Maximum input range | AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable AI2: 0 to 10VDC or PTC probe input receivable | |
Analog output | Number | 1 way: AO1 |
Type | DC voltage or DC current | |
Maximum input range | Voltage output: 0 to 10V, Current output: 0/4 to 20mA | |
logic input | Number | 0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2 15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2 note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic) |
Type | Source or Sink | |
Maximum input range | 0-24VDC |
ITEM | SPECIFICATIONS | |
logic output | Number | 0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C) 15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C) |
pulse signal output | ||
relay output | RA-RB-RC, including a NO contact and a NC contact Maximum switch capacity: T1A,T1B: 3A at 250VAC, or 4A at 30VDC T2A,T2B: 2A at 250VAC or 30VDC | |
Serial communication interface | RS485 interface supports Modbus protocol. | |
Display | 4-digit LED digital display | For display of frequency setting, output frequency, fault code and parameter setting etc. |
Environment | Standard | Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3. |
Altitude | Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m) | |
Ambient environment | 0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating. Storage: -25 ~ 70°C | |
Humidity | No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3 | |
Impact strength | 15gn for continuous 11ms, In accordance with IEC/EN60068-2-27 | |
Maximum antipollution capacity | Class 2, in accordance with IEC/EN61800-5-1 | |
Structure | Protection level | Top: IP41 (without removing the protective top cover). Other parts: IP20 |
Cooling Method | Forced Air cooling | |
Installation method | Wall mounted |
- Q: Motor 2 pole and 4 pole in the inverter with what set to show
- Motor parameters, there must be a parameter "motor pole" of the bar.
- Q: How does the laptop's power adapter open
- Control Panel - System - Hardware - Device Manager - Network Adapter, right click, and the menu appears. If it is infinite, then first follow the above argument to see if it can be enabled.
- Q: What is the common COM point of the PLC and the inverter? Is it positive?
- Plc is divided into two kinds of transistor output and relay output, com side may be connected to the high level may also be connected to the low level, the general input com port then low, the output port com mouth high, specifically what to take See the data sheet. Inverter is the same, the inverter has 24v com side and 10v com side, can not be connected together, com side generally low.
- Q: I have a 11KW-4 pole inverter, now with the 4KW-4 pole motor, what impact?
- 11KW the following can be brought, the inverter rectifier module may be broken,
- Q: 6-pole motor, speed 8000 rpm, corresponding to the frequency converter output frequency is how much?
- The synchronous speed of the motor is n = 60f / p P is the pole pair number, and f is the power supply frequency. The pole pair number of the 6 pole motor is 3. Therefore, f = n * p / 60 = 8000 * 3/60 = 400Hz.
- Q: Delta VFD-F frequency converter how to adjust the number of poles
- Look at the 07 motor parameters, I VFD-F instructions need, then the mailbox sent
- Q: What is the base blockade in the drive?
- Base blockade is to deal with ul or ce such a special application of security agencies means that when the parking limit action after the base blockade even if the program can not malfunction, relative to the emergency stop circuit more harsh they will directly disconnect the power
- Q: ASUS and dell notebook power adapter can be universal?
- One, not necessarily interchangeable. Need to compare the two adapter specifications to determine: 1, the books power adapter, there are 90W and 60W of the other, some products output voltage 19V and 14V of the other. "General" conditions, as long as the output power of the adapter is the same, the output voltage is the same (current may not consider), that is, their specifications are the same, you can directly substitute. 2, however, some foreign imports of products using 110V AC products, be careful to see clearly. 3, before the use of replacement, pay attention to observe if connected to the books of the power plug specifications are different, you can not directly insert. An interface adapter can be purchased. Can also be bad adapter plug, cut into the replacement adapter; Second, for example: 1, LITEON OEM products, parameters: input AC 100 ~ 240V 1.5A, output DC 19V3.42A. Rated output power 60W; 2, ASUS books supporting products, parameters: AC 100 ~ 240V 1.5A, output DC 19V 4.74A. Rated output power 90W.
- Q: Variable frequency conversion frequency difference characteristics based on,
- Whether it is variable speed control, or string resistance speed, are the cost of energy consumption.
- Q: Three sets of batteries (540V) DC power supply U / f inverter.
- It is estimated that the battery should be string - and - series connection method, and then rectifier part of the converter (which may also be caused by the switch) is actually a series of diodes in series, positive and negative after the reverse is actually the battery is Negative shorts, resulting in burning, as to burn only one of the group of a few cells, it should be string - and - string and that group, because the parallel to bear it double voltage.