Technical specifications
Table 2.3: Technical Parameters of QD200 Series Frequency Inverters
ITEM | SPECIFICATIONS | |
Main Input | Rated voltage and frequency | Single-phase 200V class: 200V-240V,50Hz/60Hz |
3-phase 400V class: 380V-480V , 50Hz/60Hz | ||
Allowable value of change | Voltage: 380V-15% ~ 480V+10%; Frequency: ±15% | |
Main output | Output voltage | Maximum output voltage equals to input voltage |
Output frequency | 0.5 Hz to 400 Hz | |
Overload capacity | 150% of rated output current for 60s, 200% of rated output current for 2s | |
Control performance | Modulation mode | 3-phase PWM, 2-phase PWM |
Control mode | V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving | |
Setting method of run command | Outer terminal, keyboard panel or serial communication | |
Setting method of speed command | Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal | |
Speed setting resolution | Keyboard: 0.1 Hz | |
Analog setting: 0.05/50Hz (10bit) | ||
Speed control precision | V/f control:±2% | |
vector control without PG (open loop control): ±0.2% | ||
Speed control range | V/f control 1:40 | |
vector control without PG (open loop control) 1:200 | ||
Acceleration and Deceleration Time | 0-3200.0s | |
switching frequency | 1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency | |
Analog input | Number | 2 ways: AI1、AI2 |
Type | DC voltage or DC current | |
Maximum input range | AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable AI2: 0 to 10VDC or PTC probe input receivable | |
Analog output | Number | 1 way: AO1 |
Type | DC voltage or DC current | |
Maximum input range | Voltage output: 0 to 10V, Current output: 0/4 to 20mA | |
logic input | Number | 0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2 15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2 note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic) |
Type | Source or Sink | |
Maximum input range | 0-24VDC |
ITEM | SPECIFICATIONS | |
logic output | Number | 0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C) 15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C) |
pulse signal output | ||
relay output | RA-RB-RC, including a NO contact and a NC contact Maximum switch capacity: T1A,T1B: 3A at 250VAC, or 4A at 30VDC T2A,T2B: 2A at 250VAC or 30VDC | |
Serial communication interface | RS485 interface supports Modbus protocol. | |
Display | 4-digit LED digital display | For display of frequency setting, output frequency, fault code and parameter setting etc. |
Environment | Standard | Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3. |
Altitude | Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m) | |
Ambient environment | 0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating. Storage: -25 ~ 70°C | |
Humidity | No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3 | |
Impact strength | 15gn for continuous 11ms, In accordance with IEC/EN60068-2-27 | |
Maximum antipollution capacity | Class 2, in accordance with IEC/EN61800-5-1 | |
Structure | Protection level | Top: IP41 (without removing the protective top cover). Other parts: IP20 |
Cooling Method | Forced Air cooling | |
Installation method | Wall mounted |
- Q: Notebook power adapter on how to look at power
- Power and work voltage power adapter will be identified, you only need to distinguish between input and output on the line, the input refers to the utility power supply support, and now are generally 100V ~ 240V, so you can use in most parts of the world,
- Q: The relationship between the power supply of the notebook and the battery
- 2, when the laptop turns on the power adapter, and the battery power is low, the charging circuit detects the battery power is lower than the set value, the power adapter will side of the host power supply, while the battery charge. After the charge is restored, it is restored to the power supply state directly from the adapter. Therefore, the relationship between the power supply of the notebook and the battery is that the battery is charged by the power adapter when the battery level is below the set value.
- Q: Inverter signal line analog 4-20mA connection positive and negative can be reversed?
- Theoretically reverse seems to be possible, but the operation will be normal, you can do experiments to try what is the result. Various manufacturers of the inverter may be the treatment of this problem will be different.
- Q: Servo control system can give the inverter signal,
- If two motors are to be synchronized, only two servomotors are used, one is set to spindle and the other is set to slave.
- Q: ASUS power adapter Acer can use it
- 3. The size of the joint is appropriate. (If the connector is too loose, will be bad, excessive fever.) If it is for DELL and HP / Compaq and other notebook power adapter, will involve a decoding problem. Please pay attention when the pro to buy. Acer and Asus are not yet available. It is said that the market is also very popular universal adapter, a friend bought a LVSUN brand universal adapter LS-PAB90-BC10, with eight joints. Adapter has a liquid crystal display, you can also automatically switch the voltage, very smart, with more than a year, has also been used.
- Q: On the notebook power adapter output current and voltage issues
- On the real virtual cable that adapter is rectifier filter output, no regulator, the notebook internal regulator, the adapter does not need to regulator. 3.25A is smaller than 4.5A, because the adapter has a power margin that can be used. Summer attention to touch the adapter surface is overheating. Conditional or buy a large number of good current.
- Q: How to choose the inverter
- I was doing the inverter, you choose the words, as long as 75KW can be selected, huh, huh, because the 1440 speed is fixed, the connection can be set in the inverter itself,
- Q: The Schneider inverter reports the nlp command
- Schneider inverter reported nlp ??? main circuit no electricity 1 re-power up 2 connected to the DC reactor terminals PO, PA / + between the short wiring, the main circuit can not be powered
- Q: Short-term short-circuit converter DC link positive and negative will damage the inverter?
- This short circuit may not necessarily line, the inverter fan has three, one is no speed line, two are pulse, three are switching signal (this is very little, I only encountered several),
- Q: 55 瓩 4 pole motor with a frequency of one hour can save much electricity
- Such as: 55KW motor full load operation, 1 hour with 55 degrees of power (according to the motor power slightly different changes),