Technical specifications
Table 2.3: Technical Parameters of QD200 Series Frequency Inverters
ITEM | SPECIFICATIONS | |
Main Input | Rated voltage and frequency | Single-phase 200V class: 200V-240V,50Hz/60Hz |
3-phase 400V class: 380V-480V , 50Hz/60Hz | ||
Allowable value of change | Voltage: 380V-15% ~ 480V+10%; Frequency: ±15% | |
Main output | Output voltage | Maximum output voltage equals to input voltage |
Output frequency | 0.5 Hz to 400 Hz | |
Overload capacity | 150% of rated output current for 60s, 200% of rated output current for 2s | |
Control performance | Modulation mode | 3-phase PWM, 2-phase PWM |
Control mode | V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving | |
Setting method of run command | Outer terminal, keyboard panel or serial communication | |
Setting method of speed command | Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal | |
Speed setting resolution | Keyboard: 0.1 Hz | |
Analog setting: 0.05/50Hz (10bit) | ||
Speed control precision | V/f control:±2% | |
vector control without PG (open loop control): ±0.2% | ||
Speed control range | V/f control 1:40 | |
vector control without PG (open loop control) 1:200 | ||
Acceleration and Deceleration Time | 0-3200.0s | |
switching frequency | 1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency | |
Analog input | Number | 2 ways: AI1、AI2 |
Type | DC voltage or DC current | |
Maximum input range | AI1: 0 to 5VDC, 0 to 10VDC, 0/4 to 20mA DC receivable AI2: 0 to 10VDC or PTC probe input receivable | |
Analog output | Number | 1 way: AO1 |
Type | DC voltage or DC current | |
Maximum input range | Voltage output: 0 to 10V, Current output: 0/4 to 20mA | |
logic input | Number | 0.75kw-11kW:LI1,LI2,LI3,LI4,AI1,AI2 15kW-500kW:LI,LI2,LI3,LI4,LI5,LI6,LI7,LI8,AI1,AI2 note:2 virtual logic input, capable of configuring AI1 and AI2 into logic input port (positive logic or negative logic) |
Type | Source or Sink | |
Maximum input range | 0-24VDC |
ITEM | SPECIFICATIONS | |
logic output | Number | 0.75kW-11kW: pulse signal output (LO-CLO)、relay output 1(T1A、T1B、T1C) 15kW-500kW:pulse signal output(LO-CLO)、relay output 1、2(T1A-T1B-T1C、T2A-T2B-T2C) |
pulse signal output | ||
relay output | RA-RB-RC, including a NO contact and a NC contact Maximum switch capacity: T1A,T1B: 3A at 250VAC, or 4A at 30VDC T2A,T2B: 2A at 250VAC or 30VDC | |
Serial communication interface | RS485 interface supports Modbus protocol. | |
Display | 4-digit LED digital display | For display of frequency setting, output frequency, fault code and parameter setting etc. |
Environment | Standard | Development of VSC200 series frequency inverters follows strict international standards and relevant recommended IEC and EN standards for control devices, especially IEC/EN61800-5-1 and IEC/EN61800-3. |
Altitude | Derating unnecessary when altitude is 1000m or below (Derating necessary at altitude higher than 1000m) | |
Ambient environment | 0.75kW-11kW: Reliable operation at -10 ~ 50°C without derating. When top protective cover is taken off, the environment temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 ~ 40°C without derating. Storage: -25 ~ 70°C | |
Humidity | No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3 | |
Impact strength | 15gn for continuous 11ms, In accordance with IEC/EN60068-2-27 | |
Maximum antipollution capacity | Class 2, in accordance with IEC/EN61800-5-1 | |
Structure | Protection level | Top: IP41 (without removing the protective top cover). Other parts: IP20 |
Cooling Method | Forced Air cooling | |
Installation method | Wall mounted |
- Q: Is the laptop power adapter high temperature normal? Is there anything else?
- Summer heat is normal, as long as it is not the kind of hand touch on the bubble temperature, no problem
- Q: 4 pole 380V 4-5.5KW frequency conversion motor and inverter about how much money, such as the use of electromagnetic speed motor comparison
- About 2,000 yuan, electromagnetic speed and vector inverter can bring feedback
- Q: ABB frequency converter and the difference between domestic frequency converter
- The objective lens is equivalent to the lens of the projector, the object is inverted through the objective lens, magnified real image. Eyepiece is equivalent to the ordinary magnifying glass, the real image through the eyepiece into a positive, magnified virtual image.
- Q: Laptop power adapter how to detect?
- No voltage output when no load.
- Q: The laptop's power adapter is broken how much it costs
- Buy a new, new price of dozens to one hundred. Notebook adapter, as long as the output current is greater than the old, the same voltage, with the brand can be interchangeable, Different brands of adapters to meet the above requirements, that is, insert the notebook connector is different, you can use scissors + tape,
- Q: I power adapter output current 3.25A for a 4.5A, can you use it
- No problem that nominal value is that the adapter can provide the maximum operating current to your computer current is not so big
- Q: Lenovo g450 laptop power adapter specifications is what?
- Lenovo G450 power adapter Model: ADP-90RH B LENOVO P / N: 36001681 Input: 100-240V ~ 1.5A 50-60Hz Output: 19V $ 4.74
- Q: Oil-free vertical vacuum pump why a little negative pressure inverter on the torque limit
- Here is not the inverter can solve the problem, you should first 220V single-phase AC rectifier for the DC (full-wave rectifier plus filter about 310 volts),
- Q: Will the laptop's power adapter is not the original good?
- As long as the power and current are equal or slightly larger than the original adapter, but the voltage must be equal to the original adapter on the line.
- Q: B2b frequency how to speed
- How does changing the power frequency to change the speed of the motor? When the motor is connected to the power supply to drive the normal operation of the load, at this time to change the power frequency, such as the current frequency down, the motor armature rotating magnetic field speed will decline, the rotor conductor cutting magnetic field speed decreases, turn from the induced potential , The rotor current decreases, the torque decreases, the load on the shaft does not change, the torque will be less than the load resistance torque, the motor rotor speed decreases, the rotor conductor cutting the magnetic field line speed increases, the rotor induced potential increases, the rotor current increases, The torque rises until it is equal to the load resistance torque, and the speed is smaller than the original. After stabilizing the work, the torque of the motor is the same as that of the original. (The motor torque is the same as the load torque, the load is constant and the motor torque is not changed)
Send your message to us
Frequency Inverter Single-phase 200V class 2.2KW MINI Series
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords