• Deep Well Submersible Centrifugal Water Pump System 1
  • Deep Well Submersible Centrifugal Water Pump System 2
  • Deep Well Submersible Centrifugal Water Pump System 3
Deep Well Submersible Centrifugal Water Pump

Deep Well Submersible Centrifugal Water Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
1000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1. Applications of deep weel submersible pump:
1> For water supply from wells or reservoirs.
2> For domestic use,for civil and industrial applications.
3> For garden use and irrigation. 

2. Operating conditions:
1> Maximum fluid temperature up to +35°C.
2> Maximum sand content: 0.3%.
3> Maximum immersion: 100m.    
4> Minimum well diameter: 4".    

3. Specification of Motor:
Three-phase:380-415V/50HZ    
Single-phase:220-240V/50HZ     
Equip with special start-up control box.
Internal diameter of outlet
 1.25".1.5".2"
Special features available:
1> Other voltages are acceptable.
2> Frequency 60Hz.
3> Other mechanical seal.
4> Equip with Auto-control box.

4. Description of pumps: 

Warranty: 1 years.
(according to our general sales conditions)  

Components:                                                         Material:

Pump external casing                                          AISI 304 ss

Delivery casing                                                    Cast-Cu ASTM280

Suction lantern                                                    Cast-Cu ASTM280

Diffuser                                                                Plastic.PC

Impeller                                                                Plastic.POM

Motor external casing                                            AISI 304ss

Top cover                                                         1.Cast-Cu ASTM280. 2.Cast iron G20 UNI5007

Bottom support                                                     AISI 304 ss

Mechanical seal                                                    Special seal for deep well(carbon-SIC/TC)

Bearing                                                                 NSK(Japan)

 

5. FAQ

1>.  Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2>.  Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3>.  How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.

Deep Well Submersible Centrifugal Water Pump

Deep Well Submersible Centrifugal Water Pump


Q: What is the difference between swashplate pump and crankshaft pump?
Piston pump: valve plate, valve plate, piston, piston ring, crankshaft, connecting rod and so on, all belong to its spare parts.Piston pump working principle: by the piston in the pump cylinder for reciprocating movement to suction and remove liquid.
Q: Must the water pump in the tank be all soaked in water?
Of course, if the motor is overheated, it will burn, and the temperature of the water will drop down.
Q: The suction pump has a nominal suction range of 30 metersHow deep can a well be sucked?Well, sixteen meters,
Vacuum pump plus form must not reach a standard atmospheric pressure vacuum, so the general can absorb 8 meters is very good, and the self suction pump itself and loss, the horizontal self-priming pump can suck on basic 4~6 meters is very good, self-priming pump. Suction lift of 30 meters is purely in the Mongolian people, does not comply with the laws of nature, obvious anti science.
Q: The function of centrifugal pump
4, bearings are set on the pump shaft supporting the pump shaft components, there are two kinds of rolling bearings and sliding bearings. Rolling bearings use butter as a lubricant, refueling should be appropriate, generally 2/3 ~ 3/4 of the volume is too much, will heat, too little, there is noise and fever! The plain bearings are made of transparent oil as a lubricant and fill up to the oil level. Too much oil will leak out along the pump shaft and float *, too little, the bearings will overheat and burn out, causing accidents! In the pump running process, bearing temperature is highest in 85 degrees, generally run at about 60 degrees, if higher, will find the reason (whether there is impurities, whether the oil is black, whether water) and timely processing!
Q: What are the important parameters of the pump?
The head is the unit weight of liquid pump pumping from the inlet of the pump (pump inlet flange) to the outlet of the pump (pump outlet flange) energy value. Effective energy is a Newtonian liquid through the pump unit is obtained. The N m/N=m, the height of liquid column pumping liquid used, referred to as meters.Speed nThe speed is the number of revolutions per unit time of the pump shaft. It is indicated by the symbol n. The unit is r/min.Cavitation allowance NPSHCavitation margin, also called net positive suction head, is the main parameter to indicate the cavitation performance. The cavitation margin has been expressed by delta H at homePower and efficiencyThe power of water pump usually refers to the input power, that is, the power transferred by the prime mover to the pump shaft, so it is also called shaft power. It is expressed by P;The effective power of the pump, also known as the output power, is expressed in Pe. It is the effective energy obtained by pumping the liquid out of the pump in unit time
Q: What are the ways of hydraulic pumps?
Check valves, such as single piston pumps, three piston pumps, etc.;The port of the valve arrangement, such as the radial piston pump.
Q: What is the working pressure of the hydraulic pump in the hydraulic transmission system?
The operating pressure of the hydraulic system depends mainly on the load. Generally speaking, the working pressure of the hydraulic system means the highest working pressure of the system. If the pressure is higher than the value of the equipment, the relief valve works to relieve pressure. The actual working pressure of the hydraulic system is determined by the load, which refers to the actual pressure of the hydraulic oil and can be read directly from the pressure gauge. The pressure increases with the increase of the load. You Li's balance can know: the thrust of the cylinder = the load, the thrust of the cylinder = the working pressure of the hydraulic oil, the working area of the cylinder, the working pressure = the load / the area of the cylinder.
Q: Which nuclear submarines use the shaftless pump technology?
At present, the submarine has been used in the pump jet technology, the most representative is the United States Virginia class submarine and the Russian North Sea God class submarines.. And shaftless pump is a derivative application of superconducting technology, which is more advanced than pump jet technology..If you want to learn more about shaftless pump technology, you can find relevant papers online.
Q: Metering pumps related matters
2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
Q: What is the distance between the pump and the wall?
What do you mean by that? If your pump is parallel to the wall! Then, the wall of the pump near the wall is usually 500mm. This is an empirical data, considering the import pipe length, pump maintenance and motor heat dissipation and other aspects of the situation to determine. Dozens of pumps installed in our company are placed in this size! Hope to be of help to you.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords