CMAX Pump use 75KW Inverter Frequency
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 pc pc
- Supply Capability:
- 8000 pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Description Of CMAX Pump use 75KW Inverter Frequency
CMAX Pump use 75KW Inverter Frequency is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse
Features Of CMAX Pump use 75KW Inverter Frequency
1).Adopts 16 bit microprocessor, sine wave PWM control2).Automatic torque ascension and automatic sliding compensation function
3).Output frequency 0.1-400 Hz
4).8 period of speed setting and 7 period can be running the program
5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment
6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration
7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA
8).The built-in serial communication interface RS-485(baud rate can reach 38400)
9).Save energy running and automatic voltage stabilizing section function (AVR)
10).Adjustable V/F curve Acceleration and automatic and deceleration function
11).Simple vector control and built-in PID control, and the simple positioning function
12).Sleep/wake up function and zero velocity keep function
Structure Of CMAX Pump use 75KW Inverter Frequency
Application Of CMAX Pump use 75KW Inverter Frequency
★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.★Plastic: extruder, hauling machine, decorating machine, etc.
★Pharmacy: mixer, roaster, etc.
★Woodworking: engraving machine, sander, veneer peeling lathe, etc.
★Papermaking: single type papermaking machine, etc.
★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.
★Printing: cloth-washing machine, dye vat, etc.
★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc
★Fan and pump: kinds of fans, blowers and pumps
Performance Of CMAX Pump use 75KW Inverter Frequency
Item | Specification | |||||||
Input | Rated voltage | T4 series: Three phase 380v, ±15% | ||||||
Frequency | S/T2 series: Three/single phase 220V, ±15% | |||||||
50/60Hz ±5% | ||||||||
Output | Voltage | T4 series: Three phase 0-380V | ||||||
Frequency | S/T2 series: Three phase 0~220v | |||||||
0-400Hz | ||||||||
Overload ability | 150% rated current for 30s; 180% rated current for 1s; | |||||||
Dissipation | Cooling type | Forced Cooling | ||||||
Temperature protection | Heatsink temperature >85℃ trip protection against overheat | |||||||
Fan control | Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work | |||||||
Control | Control mode | Open-loop vector control, V/F control | ||||||
Performance | Start torque | Open-loop vector control: 0.5Hz 180%; | ||||||
VF control: 0.5Hz 150% | ||||||||
Speed range | Open-loop vector control:1:150; | |||||||
VF control:1:100 | ||||||||
Speed control precision | Open-loop vector control: ±0.2%; | |||||||
VF control:±0.5% | ||||||||
Function | Channel of operation command | Keyboard control,terminal control,communication control | ||||||
Start mode | Direct start, DC injection braking before start, speed tracking before start | |||||||
DC injection braking | Start DC injection braking, stop DC injection braking | |||||||
Dynamic braking | Built-in braking unit | |||||||
Frequency source choice | Keyboard digital frequency setting, analog AVI setting | |||||||
PID control setting, telecommunications setting | ||||||||
Frequency resolution | Keypad setting:0.01Hz; Analog setting: 0.1% | |||||||
Carrier frequency | 1Khz~12Khz, | |||||||
Acc/Dec time | 0.1~6000.0s or 0.01~600.00s | |||||||
Signal | Analog input | AVI:0~10V | ||||||
ACI:4~20mA | ||||||||
Keyboard potentiometer input: 0~10V | ||||||||
Analog output | AFM:0~10V or 0~20mA, Select through JP1 jumper | |||||||
Digital input | A total of 28 kinds of function could be selected from S0 ~S5. | |||||||
Digital output | 1 channel open collector output(MO1-MCM) | |||||||
1 channel relay output( TA-TC normally open, TB-TC normally closed; | ||||||||
Communication Port | Communication protocol | Based on RS485 hardware, support standard MODBUS protocol. | ||||||
Display Functions | Four digital tube display | Can monitor the operation state of frequency inverter flexibly and conveniently. | ||||||
Installation | Humidity | Less than 90%RH | ||||||
condensation | ||||||||
Vibration | Less than0.6G | |||||||
Elevation | 0~1000m, reduce the rated specification 10% when lift 1000m for each. | |||||||
Storage temperature | -20~60℃ | |||||||
Structure | Defend degree | IP20 |
- Q: Laptop adapter
- Should be a laptop power adapter, that is, laptop charger. Laptop charger (Laptop Charger), that is, laptop charger. The traditional notebook charger can only output a single voltage to a type of notebook computer charging, the industry called the traditional notebook power adapter for the single band notebook charger (mainly in order to distinguish between the universal notebook charger.)
- Q: ABB frequency converter and the difference between domestic frequency converter
- Both the eyepiece and the objective lens are convex lenses with different focal lengths. The focal length of the convex lens of the objective lens is smaller than the focal length of the convex lens of the eyepiece.
- Q: Will the asynchronous motor pole change the number of speed control can also be combined with the frequency converter
- Of course, because the factors that determine the speed of asynchronous motor power supply voltage, frequency and motor pole pairs, so asynchronous motor speed can be achieved by changing the number of magnetic pole pairs, but this method needs to make a greater motor changes, Trouble, and change the number of poles can only achieve a single speed change;
- Q: My motor is a low frequency 8 pole motor, about 80W. I would like to choose a frequency converter
- VACON frequency converter (Finland wholly owned) Model: NXL 0006 2 C1N1 Parameters: Low overload Continuous current: 6.6A 110% Overload current: 7.2A 110% Overload power: 1.5kw (ambient 40 ℃) High Overload Continuous Current: 4.8A 150% Overload Current: 7.2A 150% Overload Power: 1.1kw (Ambient 50 ℃) Maximum current: 9.6A Weight: 2.0kg Mechanical specifications: 84 x 220 x 172 Please consult the pre-sale technical support department
- Q: The motor is 2 pole with the inverter frequency to 50hz why the speed is only 1500 rpm
- Motor speed formula: N = 60f / p In the above formula N - the speed of the motor (r / min); 60 - per minute (s); F - power frequency (hz); P - pole pairs of motor rotating magnetic fields.
- Q: Lenovo g450 laptop power adapter specifications is what?
- Lenovo G450 power adapter Model: ADP-90RH B LENOVO P / N: 36001681 Input: 100-240V ~ 1.5A 50-60Hz Output: 19V $ 4.74
- Q: Variable frequency conversion frequency difference characteristics based on,
- Frequency conversion is better, you can smoothly change the synchronous speed. Change the difference is relatively poor, also known as "energy consumption slip" speed. Synchronous speed unchanged, the slip rate has changed, so the speed changed.
- Q: Short-term short-circuit converter DC link positive and negative will damage the inverter?
- the switch signal Is the fan running up after the speed line is low, this can be shorted. Pulse is every turn a circle, send two pulses to the speed line
- Q: Does the inverter set the number of poles to match the number of poles of the motor?
- Variable-frequency (VFD) is the application of frequency conversion technology and microelectronics technology, by changing the motor operating frequency mode to control the AC motor power control equipment. The inverter is mainly composed of rectifier (AC variable DC), filter, inverter (DC variable AC), brake unit, drive unit, detection unit micro-processing unit and so on.
- Q: Quartet of the TA, TC terminals have positive and negative?
- The TC terminal has no positive and negative poles, which are passive programmable relays
1. Manufacturer Overview
Location | Zibo, China |
Year Established | 2004 |
Annual Output Value | Below US$1 Million |
Main Markets | Middle-East America; Mid East; Northern Europ; Africa; Southeast Asia |
Company Certifications | CE;ISO |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Qingdao |
Export Percentage | 1% - 10% |
No.of Employees in Trade Department | 500-999 People |
Language Spoken: | English; Chinese |
b) Factory Information | |
Factory Size: | Above 50,000 square meters |
No. of Production Lines | Above 8 |
Contract Manufacturing | |
Product Price Range | High; Average |
Send your message to us
CMAX Pump use 75KW Inverter Frequency
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 pc pc
- Supply Capability:
- 8000 pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords