CE Approved 90KW Inverter Frequency
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 pc pc
- Supply Capability:
- 5000pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Description Of CE Approve
d 90KW Inverter Frequency
Features Of CE Approved 90KW Inverter Frequency
1).Adopts 16 bit microprocessor, sine wave PWM control2).Automatic torque ascension and automatic sliding compensation function
3).Output frequency 0.1-400 Hz
4).8 period of speed setting and 7 period can be running the program
5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment
6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration
7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA
8).The built-in serial communication interface RS-485(baud rate can reach 38400)
9).Save energy running and automatic voltage stabilizing section function (AVR)
10).Adjustable V/F curve Acceleration and automatic and deceleration function
11).Simple vector control and built-in PID control, and the simple positioning function
12).Sleep/wake up function and zero velocity keep function
Structure Of CE Approved 90KW Inverter Frequency
Application Of CE Approved 90KW Inverter Frequency
★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.★Plastic: extruder, hauling machine, decorating machine, etc.
★Pharmacy: mixer, roaster, etc.
★Woodworking: engraving machine, sander, veneer peeling lathe, etc.
★Papermaking: single type papermaking machine, etc.
★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.
★Printing: cloth-washing machine, dye vat, etc.
★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc
★Fan and pump: kinds of fans, blowers and pumps
Performance Of CE Approved 90KW Inverter Frequency
Item | Specification | |||||||
Input | Rated voltage | T4 series: Three phase 380v, ±15% | ||||||
Frequency | S/T2 series: Three/single phase 220V, ±15% | |||||||
50/60Hz ±5% | ||||||||
Output | Voltage | T4 series: Three phase 0-380V | ||||||
Frequency | S/T2 series: Three phase 0~220v | |||||||
0-400Hz | ||||||||
Overload ability | 150% rated current for 30s; 180% rated current for 1s; | |||||||
Dissipation | Cooling type | Forced Cooling | ||||||
Temperature protection | Heatsink temperature >85℃ trip protection against overheat | |||||||
Fan control | Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work | |||||||
Control | Control mode | Open-loop vector control, V/F control | ||||||
Performance | Start torque | Open-loop vector control: 0.5Hz 180%; | ||||||
VF control: 0.5Hz 150% | ||||||||
Speed range | Open-loop vector control:1:150; | |||||||
VF control:1:100 | ||||||||
Speed control precision | Open-loop vector control: ±0.2%; | |||||||
VF control:±0.5% | ||||||||
Function | Channel of operation command | Keyboard control,terminal control,communication control | ||||||
Start mode | Direct start, DC injection braking before start, speed tracking before start | |||||||
DC injection braking | Start DC injection braking, stop DC injection braking | |||||||
Dynamic braking | Built-in braking unit | |||||||
Frequency source choice | Keyboard digital frequency setting, analog AVI setting | |||||||
PID control setting, telecommunications setting | ||||||||
Frequency resolution | Keypad setting:0.01Hz; Analog setting: 0.1% | |||||||
Carrier frequency | 1Khz~12Khz, | |||||||
Acc/Dec time | 0.1~6000.0s or 0.01~600.00s | |||||||
Signal | Analog input | AVI:0~10V | ||||||
ACI:4~20mA | ||||||||
Keyboard potentiometer input: 0~10V | ||||||||
Analog output | AFM:0~10V or 0~20mA, Select through JP1 jumper | |||||||
Digital input | A total of 28 kinds of function could be selected from S0 ~S5. | |||||||
Digital output | 1 channel open collector output(MO1-MCM) | |||||||
1 channel relay output( TA-TC normally open, TB-TC normally closed; | ||||||||
Communication Port | Communication protocol | Based on RS485 hardware, support standard MODBUS protocol. | ||||||
Display Functions | Four digital tube display | Can monitor the operation state of frequency inverter flexibly and conveniently. | ||||||
Installation | Humidity | Less than 90%RH | ||||||
condensation | ||||||||
Vibration | Less than0.6G | |||||||
Elevation | 0~1000m, reduce the rated specification 10% when lift 1000m for each. | |||||||
Storage temperature | -20~60℃ | |||||||
Structure | Defend degree | IP20 |
- Q: 380V motor addition to the inverter, but also how to change its speed?
- Rotary motor rotor series resistance adjustable speed. 4. Change the slip electromagnetic speed (slip motor)
- Q: Inverter alarm a043, how is it
- When a signal failure occurs, use the DTI board, if necessary, change P215. With P806 (Follow the parameter description) during operation can be converted to no encoder operation A043 is: n-actjump exceeds the allowable change speed of the speed encoder signal (P215) In addition, for the synchronous motor (P095 = 12): The motor speed is 2% higher than the inverter release time point. The inverter in the ready state can not exit. Check processing: Check if the cable is disconnected Check the tachometer to shield the ground Not only on the motor side but also on the inverter side The encoder cable does not allow disconnection Use only recommended encoders The encoder cable is not allowed to be laid with the power cable
- Q: Laptop power adapter output voltage is not the same as the current? What's the effect?
- I would like to elaborate on the basic principle of the large standard current power supply can replace the small standard current power supply. Some friends have misunderstood, that a large nominal current power will burn books, because the current big thing. In fact, how much current in the same voltage depends on the load, that is, the work of the books, when the books of high-load operation, the current larger, the books into the standby time, the current is smaller, in short, On the voltage divided by the equivalent resistance of the books. Large nominal current power supply has enough current margin, will not be replaced by a small standard current power supply after the overheating or output voltage is too low. On the contrary, with a small current power supply instead of high current power on the existence of the above risks. But some friends with 56w power supply instead of 72w with no problem, because the power adapter is usually designed to leave a certain margin, the load power should be less than the power supply,
- Q: 11kw 6-pole motor can be used to adjust the inverter to 1800RPM?
- Frequency conversion frequency f to 90Hz can. 1800 = 60x90 / 3,3 that is 3 pole, is 6 pole. Regardless of load.
- Q: 18: 5 kilowatts bipolar multi-pole pump motor with inverter
- With a 18.5kw inverter can ah such as ABBACS510 series
- Q: Why the notebook power adapter can not be universal
- First, the interface is different Most laptop power adapter brands have different interfaces, which means that other brands of power adapters can not be plugged into your laptop for power supply. The interface is relatively safe, because at least you will not plug in the current or voltage does not meet the power adapter to the laptop power supply, which led to computer hardware damage.
- Q: Laptop power adapter is used to do what
- Simply put the transfer into DC China's electricity is 220V AC, and the notebook is a direct current, the need for adapter to rectify, filter, regulator, and finally we need to form a direct current
- Q: How to make the motor speed (control speed), can not use frequency
- If you use AC asynchronous motor speed control in three ways: 1 / variable speed control. By changing the motor stator pole pairs to speed, not the linear speed for the sub-file speed, the motor structure and electrical control more complex. 2 / electromagnetic speed control. Driven by the magnet magnet, the electromagnetic coil through the variable size of the DC to speed, for the linear speed, but a waste of energy 3 / frequency control. Through the inverter speed, stepless speed regulation, speed control effect is good, but one-time investment. If the DC motor speed is to change the armature or the excitation coil voltage to achieve speed. Application in the relatively high demand, a one-time investment is relatively large
- Q: 90KW inverter start 90KW, 4-pole motor and 6-pole motor j What is the difference? The inverter can be used for it?
- Three-phase AC induction motor, 4-pole speed is generally 1480 rpm, 6-pole speed was 980 rpm
- Q: Quartet of the TA, TC terminals have positive and negative?
- This can not be said to be positive and negative, should be called the public, TA, is the common.
1. Manufacturer Overview
Location | Zibo, China |
Year Established | 2004 |
Annual Output Value | Below US$1 Million |
Main Markets | Middle-East America; Mid East; Northern Europ; Africa; Southeast Asia |
Company Certifications | CE;ISO |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Qingdao |
Export Percentage | 1% - 10% |
No.of Employees in Trade Department | 500-999 People |
Language Spoken: | English; Chinese |
b) Factory Information | |
Factory Size: | Above 50,000 square meters |
No. of Production Lines | Above 8 |
Contract Manufacturing | |
Product Price Range | High; Average |
Send your message to us
CE Approved 90KW Inverter Frequency
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 pc pc
- Supply Capability:
- 5000pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords