Description Of CE Approve
d 90KW Inverter Frequency
Features Of CE Approved 90KW Inverter Frequency
1).Adopts 16 bit microprocessor, sine wave PWM control2).Automatic torque ascension and automatic sliding compensation function
3).Output frequency 0.1-400 Hz
4).8 period of speed setting and 7 period can be running the program
5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment
6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration
7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA
8).The built-in serial communication interface RS-485(baud rate can reach 38400)
9).Save energy running and automatic voltage stabilizing section function (AVR)
10).Adjustable V/F curve Acceleration and automatic and deceleration function
11).Simple vector control and built-in PID control, and the simple positioning function
12).Sleep/wake up function and zero velocity keep function
Structure Of CE Approved 90KW Inverter Frequency
Application Of CE Approved 90KW Inverter Frequency
★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.★Plastic: extruder, hauling machine, decorating machine, etc.
★Pharmacy: mixer, roaster, etc.
★Woodworking: engraving machine, sander, veneer peeling lathe, etc.
★Papermaking: single type papermaking machine, etc.
★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.
★Printing: cloth-washing machine, dye vat, etc.
★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc
★Fan and pump: kinds of fans, blowers and pumps
Performance Of CE Approved 90KW Inverter Frequency
Item | Specification | |||||||
Input | Rated voltage | T4 series: Three phase 380v, ±15% | ||||||
Frequency | S/T2 series: Three/single phase 220V, ±15% | |||||||
50/60Hz ±5% | ||||||||
Output | Voltage | T4 series: Three phase 0-380V | ||||||
Frequency | S/T2 series: Three phase 0~220v | |||||||
0-400Hz | ||||||||
Overload ability | 150% rated current for 30s; 180% rated current for 1s; | |||||||
Dissipation | Cooling type | Forced Cooling | ||||||
Temperature protection | Heatsink temperature >85℃ trip protection against overheat | |||||||
Fan control | Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work | |||||||
Control | Control mode | Open-loop vector control, V/F control | ||||||
Performance | Start torque | Open-loop vector control: 0.5Hz 180%; | ||||||
VF control: 0.5Hz 150% | ||||||||
Speed range | Open-loop vector control:1:150; | |||||||
VF control:1:100 | ||||||||
Speed control precision | Open-loop vector control: ±0.2%; | |||||||
VF control:±0.5% | ||||||||
Function | Channel of operation command | Keyboard control,terminal control,communication control | ||||||
Start mode | Direct start, DC injection braking before start, speed tracking before start | |||||||
DC injection braking | Start DC injection braking, stop DC injection braking | |||||||
Dynamic braking | Built-in braking unit | |||||||
Frequency source choice | Keyboard digital frequency setting, analog AVI setting | |||||||
PID control setting, telecommunications setting | ||||||||
Frequency resolution | Keypad setting:0.01Hz; Analog setting: 0.1% | |||||||
Carrier frequency | 1Khz~12Khz, | |||||||
Acc/Dec time | 0.1~6000.0s or 0.01~600.00s | |||||||
Signal | Analog input | AVI:0~10V | ||||||
ACI:4~20mA | ||||||||
Keyboard potentiometer input: 0~10V | ||||||||
Analog output | AFM:0~10V or 0~20mA, Select through JP1 jumper | |||||||
Digital input | A total of 28 kinds of function could be selected from S0 ~S5. | |||||||
Digital output | 1 channel open collector output(MO1-MCM) | |||||||
1 channel relay output( TA-TC normally open, TB-TC normally closed; | ||||||||
Communication Port | Communication protocol | Based on RS485 hardware, support standard MODBUS protocol. | ||||||
Display Functions | Four digital tube display | Can monitor the operation state of frequency inverter flexibly and conveniently. | ||||||
Installation | Humidity | Less than 90%RH | ||||||
condensation | ||||||||
Vibration | Less than0.6G | |||||||
Elevation | 0~1000m, reduce the rated specification 10% when lift 1000m for each. | |||||||
Storage temperature | -20~60℃ | |||||||
Structure | Defend degree | IP20 |
- Q: Laptop warranty period is not over, the power adapter is broken, repair money?
- Look at your reinsurance period if not in the warranty period is not man-made damage can be changed or for the change
- Q: How to choose the right inverter?
- Inverter selection science or not for the normal operation of the frequency conversion system is essential. Many beginners on the general inverter selection method is not enough understanding, or even know the method, not sure the choice of the inverter model is positive solution, the following for everyone to solve the mystery. Inverter selection first look at the AC motor. Because the frequency conversion system generally first determine the motor, then select the inverter. In principle, it is necessary to determine the inverter model based on the actual current at which the AC motor is operating for a long time, and not on the motor nameplate. Inverter selection next depends on the load type. Frequency conversion system driven load equipment can be divided into three types: constant torque load, constant power load, fan, pump load, different load type select the inverter model is different.
- Q: How does the laptop's power adapter open
- Control Panel - System - Hardware - Device Manager - Network Adapter, right click, and the menu appears. If it is infinite, then first follow the above argument to see if it can be enabled.
- Q: How do I protect the inverter when the three-phase two-pole motor is running?
- A: At this time to put the heart in the stomach, wait and see the change, what do not move (to prevent the accident to expand), until the motor stops, and then confirm, what kind of protection: alarm (alarm automatically after the release) or failure , Such as: over-voltage, overload, over-temperature, etc., and then the right medicine; inverter in the run which is not allowed, forced parking stop. Otherwise it will cause serious damage to the inverter.
- Q: I have a 5.5 kilowatts of 4-pole motor, want to pass through the inverter, slow down to 130 per minute use, eliminating the need for speed,
- wo recommendations, the first, the use of vector control of the inverter, you are expected to run the frequency of about 5Hz, this time, ordinary V / F inverter output torque may be small, not necessarily meet the requirements, of course, if it is High-end imported inverter, the problem should be small, with the domestic vector inverter, the frequency can also be full torque output;
- Q: Acer laptop power adapter
- It might be bad, you have to determine whether the adapter or adapter adapter directly change.
- Q: Is the inverter output current proportional to the output torque?
- The output voltage of the inverter is proportional to the frequency, which is to keep the motor flux constant, T = KIφ so the motor output torque is proportional to the inverter current.
- Q: Laptop power supply 20V 3.5A can use 20V 4.5A power adapter Mody, what impact?
- The current will be great ... ... a long time on the bad
- Q: Short-term short-circuit converter DC link positive and negative will damage the inverter?
- This short circuit may not necessarily line, the inverter fan has three, one is no speed line, two are pulse, three are switching signal (this is very little, I only encountered several),
- Q: First reduce the frequency of about one-third of the test, not the case, then appropriate adjustments!
- In the inverter in the following 18.5kw inverter will bring their own braking unit for some special occasions, such as the inverter at high speed due to production needs, must be 1 second, or less time to stop, in the stop when the frequency The internal DC bus voltage is too high, the inverter will be reported over-voltage fault, in the positive and negative connected bk-dk connected to a resistor to the inverter discharge, the inverter will not report over-voltage failure
1. Manufacturer Overview
Location | Zibo, China |
Year Established | 2004 |
Annual Output Value | Below US$1 Million |
Main Markets | Middle-East America; Mid East; Northern Europ; Africa; Southeast Asia |
Company Certifications | CE;ISO |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Qingdao |
Export Percentage | 1% - 10% |
No.of Employees in Trade Department | 500-999 People |
Language Spoken: | English; Chinese |
b) Factory Information | |
Factory Size: | Above 50,000 square meters |
No. of Production Lines | Above 8 |
Contract Manufacturing | |
Product Price Range | High; Average |
Send your message to us
CE Approved 90KW Inverter Frequency
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 pc pc
- Supply Capability:
- 5000pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords