Description Of CE Approved 90KW Inverter Frequency
CE Approved 90KW Inverter Frequency is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse
Features Of CE Approved 90KW Inverter Frequency
1).Adopts 16 bit microprocessor, sine wave PWM control2).Automatic torque ascension and automatic sliding compensation function
3).Output frequency 0.1-400 Hz
4).8 period of speed setting and 7 period can be running the program
5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment
6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration
7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA
8).The built-in serial communication interface RS-485(baud rate can reach 38400)
9).Save energy running and automatic voltage stabilizing section function (AVR)
10).Adjustable V/F curve Acceleration and automatic and deceleration function
11).Simple vector control and built-in PID control, and the simple positioning function
12).Sleep/wake up function and zero velocity keep function
Structure Of CE Approved 90KW Inverter Frequency
Application Of CE Approved 90KW Inverter Frequency
★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.★Plastic: extruder, hauling machine, decorating machine, etc.
★Pharmacy: mixer, roaster, etc.
★Woodworking: engraving machine, sander, veneer peeling lathe, etc.
★Papermaking: single type papermaking machine, etc.
★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.
★Printing: cloth-washing machine, dye vat, etc.
★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc
★Fan and pump: kinds of fans, blowers and pumps
Performance Of CE Approved 90KW Inverter Frequency
Item | Specification | |||||||
Input | Rated voltage | T4 series: Three phase 380v, ±15% | ||||||
Frequency | S/T2 series: Three/single phase 220V, ±15% | |||||||
50/60Hz ±5% | ||||||||
Output | Voltage | T4 series: Three phase 0-380V | ||||||
Frequency | S/T2 series: Three phase 0~220v | |||||||
0-400Hz | ||||||||
Overload ability | 150% rated current for 30s; 180% rated current for 1s; | |||||||
Dissipation | Cooling type | Forced Cooling | ||||||
Temperature protection | Heatsink temperature >85℃ trip protection against overheat | |||||||
Fan control | Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work | |||||||
Control | Control mode | Open-loop vector control, V/F control | ||||||
Performance | Start torque | Open-loop vector control: 0.5Hz 180%; | ||||||
VF control: 0.5Hz 150% | ||||||||
Speed range | Open-loop vector control:1:150; | |||||||
VF control:1:100 | ||||||||
Speed control precision | Open-loop vector control: ±0.2%; | |||||||
VF control:±0.5% | ||||||||
Function | Channel of operation command | Keyboard control,terminal control,communication control | ||||||
Start mode | Direct start, DC injection braking before start, speed tracking before start | |||||||
DC injection braking | Start DC injection braking, stop DC injection braking | |||||||
Dynamic braking | Built-in braking unit | |||||||
Frequency source choice | Keyboard digital frequency setting, analog AVI setting | |||||||
PID control setting, telecommunications setting | ||||||||
Frequency resolution | Keypad setting:0.01Hz; Analog setting: 0.1% | |||||||
Carrier frequency | 1Khz~12Khz, | |||||||
Acc/Dec time | 0.1~6000.0s or 0.01~600.00s | |||||||
Signal | Analog input | AVI:0~10V | ||||||
ACI:4~20mA | ||||||||
Keyboard potentiometer input: 0~10V | ||||||||
Analog output | AFM:0~10V or 0~20mA, Select through JP1 jumper | |||||||
Digital input | A total of 28 kinds of function could be selected from S0 ~S5. | |||||||
Digital output | 1 channel open collector output(MO1-MCM) | |||||||
1 channel relay output( TA-TC normally open, TB-TC normally closed; | ||||||||
Communication Port | Communication protocol | Based on RS485 hardware, support standard MODBUS protocol. | ||||||
Display Functions | Four digital tube display | Can monitor the operation state of frequency inverter flexibly and conveniently. | ||||||
Installation | Humidity | Less than 90%RH | ||||||
condensation | ||||||||
Vibration | Less than0.6G | |||||||
Elevation | 0~1000m, reduce the rated specification 10% when lift 1000m for each. | |||||||
Storage temperature | -20~60℃ | |||||||
Structure | Defend degree | IP20 |
- Q:How do I select a drive? Which brand is better
- ?11, the inverter drives the synchronous motor, compared with the power frequency power regulator, reduce the output capacity of 10% to 20%, the inverter's continuous output current is greater than the synchronous motor rated current and synchronous pull the current value of the unit value product. ????12, for the compressor, vibration and other torque fluctuations in the load and the hydraulic pump and other peak load case, if the motor in accordance with the rated current or power value of the inverter, then there may be due to peak current over-current protection Action phenomenon. Therefore, you should understand the frequency of the operation of the situation, select the maximum current than the maximum current output of the inverter. When the inverter drives the submersible pump motor, the rated current is greater than the rated current of the submersible pump motor because the rated current of the submersible pump motor is greater than the rated current of the normal motor. ????13, when the inverter control Roots blower, because of its large starting current, so select the inverter must pay attention to whether the capacity of the inverter is large enough. ????14, select the inverter, be sure to pay attention to whether the protection level with the scene to match. Otherwise the scene of dust, water vapor will affect the long-term operation of the inverter. ????15, single-phase motor is not suitable for inverter drive. Recommended Ampang letter converter, domestic brand, quality and stability, first-class service, trustworthy!
- Q:Is the laptop power adapter long-haul?
- As long as the power, regardless of your access to the computer, the adapter is working. In fact, not much harm, anyway, five years of notebook life, this thing as long as not deliberately to damage, will be very durable, worse than the important parts of the computer slow. As long as the big brand, nothing Even if you broke, this thing can value a few money? In fact, the proposal or pull it, on the ground stumbling ... ...
- Q:Laptop power adapter (no power supply, but indicator light)
- Notebook power adapter can not charge, but the indicator light does not light the common reasons are: 1, the power adapter is broken or the connector is broken. 2, the power adapter output problem, no output or output is too low, can not give the computer charge. 3, the notebook charging interface is broken, not into the electricity charge. 4, the notebook power management circuit out of the fault, resulting in can not charge.
- Q:What is the motor series parameter setting of the inverter? If it is with the spindle,
- Ordinary inverter standard drive is a 4-pole motor, the greater the number of poles of the motor, the greater the rated current, the motor pole number is the frequency converter when the self-learning automatically set, in the vector control must be self-learning
- Q:Laptop computer about electricity no electricity, is the power adapter problem?
- This situation is definitely not about what power off, if it is really about electricity no electricity, then your laptop is a one-time shutdown, rather than the screen flashing. I think this situation is more like a laptop screen lamp problem. Is unlikely to be a power problem. The screen flashes from the surface that there may be enough current. If the adapter can not provide enough current for the notebook, then the notebook will be over-current protection, which automatically shut down. You can find an adapter with the same output voltage as your adapter, the output power is greater than or equal to your adapter other adapter, if the situation remains the same, then it is certainly the problem of the lamp. But the inferred will not be a power problem.
- Q:Three sets of batteries (540V) DC power supply U / f inverter.
- It is estimated that the battery should be string - and - series connection method, and then rectifier part of the converter (which may also be caused by the switch) is actually a series of diodes in series, positive and negative after the reverse is actually the battery is Negative shorts, resulting in burning, as to burn only one of the group of a few cells, it should be string - and - string and that group, because the parallel to bear it double voltage.
- Q:Inverter ACS355 If the speed is outside the allowable range, how to set the limit value
- 1. Set 2002 MAXIMUM SPEED Defines the maximum permissible speed.
- Q:With the inverter control fan 37Kw4 pole with what model inverter
- Universal or light-load type, the brand is not limited.
- Q:What is the single axis of the inverter and multi-axis applications
- The frequency changer mainly consists of rectification (alternating current direct current), filter, re-rectification (DC variable AC), brake unit, drive unit, detection unit micro-processing unit and so on.
- Q:6-pole motor, speed 8000 rpm, corresponding to the frequency converter output frequency is how much?
- Such a high speed estimated motor can not reach, to increase the gearbox Specific algorithm: n = 60f / p P is the number of pole pairs, f is the frequency. The pole pair number of the 6 pole motor is 3. F = n * p / 60 = 8000 * 3/60 = 400 Hz.
1. Manufacturer Overview |
|
---|---|
Location | Zibo, China |
Year Established | 2004 |
Annual Output Value | Below US$1 Million |
Main Markets | Middle-East America; Mid East; Northern Europ; Africa; Southeast Asia |
Company Certifications | CE;ISO |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | Qingdao |
Export Percentage | 1% - 10% |
No.of Employees in Trade Department | 500-999 People |
Language Spoken: | English; Chinese |
b)Factory Information | |
Factory Size: | Above 50,000 square meters |
No. of Production Lines | Above 8 |
Contract Manufacturing | |
Product Price Range | High; Average |
Send your message to us
CE Approved 90KW Inverter Frequency
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 pc pc
- Supply Capability:
- 5000pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords