Specifications of AC Motor Drive Variable Frequency Drive
Direct medium voltage input and output
IGBT power units in series to obtain MV by means of overlap wave
Up to 40% saving rate
Application Fields of AC Motor Drive Variable Frequency Drive
Power Generation: Induced draft fan, forced draft fan, condensate pump, feed pump, primary air fan, secondary air fan, booster fan, circulating pump, mill fan, slurry pump etc
Cement: draft fan, high-temperature fan, air blower, dust collection fan etc.
Metallurgy: blast furnace blower, slurry pump, feed water pump, dust fan, compressor etc.
Petroleum&Chemical: Water injection pump, crude oil pump, Compressor, fan, circulation pump, etc
Urban water supply: Water delivery pump, water intake pump, water supply pump, sewage treatment industry, self-fractionating pump etc
Minerals & Mining: Mud pump, ventilation fan, slurry pump etc
Others: Loads such as fan, pump and compressor in pharmaceutical, paper making and wind tunnel test.
Especially for: Fan and Pump
Power Plant | Pump, Fans |
Steel Plant | Fans |
Cement Plant | Fans |
Product Structure
AC Motor Drive Variable Frequency Drive Consists Of By-pass Cabinet, Transformer Cabinet, Power Unit Cabinet And Controller Cabinet From Left To Right.
Technical advantages of AC Motor Drive MV Variable Frequency Drive
No need of extra output filtering device
Directly driving the general medium voltage synchronous or asynchronous motor and the temperature of the motor will not be increased.
No need of motor derating operation
No dv/dt damage to insulation of motor and cable
No torque ripple induced by harmonics, and the service life of motors and mechanism devices can be extended
No cable length limited when voltage drop is in the allowable range.
Besides the above advantages, AC Motor Drive MV Variable Frequency Drive has the following functions and features:
Protection of overload, overheat, over-current, open-phase, grounding, over-voltage, negative sequence.
Current limited function
Interlock protection of control power supply
Two sets of control power hot standby for redundancy
Power cell by-pass function
Control cabinet automatic bypass function
Cabinet door opening alarm function
Lock-phase function
Synchronizing switch function between variable frequency and power frequency (optional)
Soft start of motors, no impact to mechanical equipment and network
Voltage source High-high variable frequency drive, it can realize No-step speed regulation, which makes the typical motors into intelligent motors.
High quality power input: By phase shifting of the secondary winding and multi-pulse diode rectifier, isolated powers can be acquired and supplied for power cells. (18 pulses for 3/3.3kV, 30/36 pulses for 6/6.6kV, 48/54 pulses for 10/11kV) By using the technique of multi-pulse rectifier, the harmonic current could be eliminated greatly.
Power cell communicate with controller through optic-fiber, completely electric isolated
Inner set PID regulator, can realize running in closed-loop
Multiple communication methods with host computer, isolated RS485 interface, standard MODBUS RTU, communication protocol, PROFIBUS DP (optional), industrial Ethernet communication protocol (optional)
Accurately fault records, can inquiry information and locate fault
Compact construction, reasonable layout (can do customer-design)
Very good protective design to dust, ferrum pulveratum, acid mist, moisture etc.
Bypass cabinethas a function of "five-protection", meanwhile, it has a pressure relief channel to ensure the safety of operators.
Modularized design of power units, interchangeable and easy to produce and repair.
Technical parameters of AC Motor Drive Variable Frequency Drive
Series No | Parameters | Value |
1 | HVF Capacity(KVA) | 250~8750kVA |
2 | Power of adaptive motor(KW) | 200~7000KW |
3 | Input Frequency(Hz) | 45~65Hz |
4 | Rated input voltage(kV) | 3/3.3kV/4.16kV/6/6.6kV/10/11kV (+15%~ -35%) |
5 | THDi at power grid | <3% (Permissible value≤4%) |
6 | THDu at output side | <3% (Permissible value≤5%) |
7 | Input power factor | >0.95%(>20% of rated load) |
8 | Efficiency | >97%(under a rated load) |
9 | Output frequency(Hz) | 0.5~120Hz |
10 | Output frequency resolution | 0.01Hz |
11 | Rated output current(A) | 36~600A |
12 | Overload capability | 120%(1min), 150%(3s), 200%(Immediate protection) |
13 | Control mode | V/F control or Vector control |
14 | Logical control I/O signal | 16 channels respectively |
15 | Analog input | 0~10V/4~20mA |
16 | Analog output | 0~10V/4~20mA Optional (2 channels) |
17 | Boolean input/output | Communications/Default point (expandable) |
18 | Acc & Dec time (S) | 0.1~3000s |
19 | Communication with host | CAN, Profibus, Modbus, RS232, RS485 etc |
20 | Cooling mode | Forced air cooling |
21 | Storage temperature | 00C~450C |
22 | Ambient temperature | -350C~+450C |
23 | Ambient humidity | 95%, no condensation |
24 | Protection grade | IP40 |
25 | Noise | <70DB |
- Q: How to choose the right inverter?
- , fan, pump load This is the most suitable for use in frequency conversion speed of the scene environment, the inverter function technology is not too high requirements, the use of inverter energy saving effect is remarkable. For example: a large-scale heating equipment in a large-scale heating system, including blower, induced draft fan (centrifugal fan) inverter configuration configuration with the power of the P-type machine; water pump (centrifugal pump) inverter configuration configuration with the power of the P-type machine ; Conveyor pump frequency converter selection configuration with the power of G-type machine; belt machine (coal feeder) inverter configuration configuration to enlarge a file of the G-type machine; slag converter inverter configuration configuration to enlarge a file of the G-type machine; Crusher (coal crusher) inverter configuration configuration to enlarge a file or two stalls of the G-type machine.
- Q: What parts of the inverter composition
- Simply put, the inverter is mainly composed of rectifier (AC variable DC), filter, inverter (DC variable AC), brake unit, drive unit, detection unit micro-processing unit
- Q: 65w adapter and 90w laptop power adapter What is the difference?
- 65W and 90W is mainly based on your laptop power configuration, the general integrated graphics with 65W, discrete graphics because of the need for additional power supply, so the general need 90W, of course, there are some low-power CPU, such as 25WCPU , 35W, 45W difference, these are the beginning of the manufacturer according to the notebook's power consumption count a maximum power, and then give your laptop with adapter 90W adapter can replace 65W, as long as the interface is the same, but 65W instead of 90W sometimes there may be insufficient power lead to automatic shutdown. In general, the greater the number of watts, the larger the head, because the adapter is actually a coil will be 220V into 19V, according to the power to determine the head, the larger the watt, the same 19V, then the output current will be greater
- Q: What is the single axis of the inverter and multi-axis applications
- Inverter is the application of frequency conversion technology and microelectronics technology, by changing the motor power supply frequency and amplitude of the way to control the AC motor power transmission components.
- Q: Can the notebook's power adapter be mixed?
- At present, the market sales of notebook power is generally 90 watts and 65 watts two, using integrated graphics, or configure the low-end notebook, usually 65 watts. Using the independence was, the configuration of high-end, or the game audio and video of this, are generally 90 watts. If the laptop's power adapter is damaged can not be used, it is best to repair the department as soon as possible to repair. If it is for emergency, before using the two adapters to check the output power and current and voltage are conceded, as the adapter input current and voltage is not the same, should be the general household voltage is 220V, so almost all of the notebook power The adapter is 100-240V ~ 1.5A words, as long as the output current and voltage values, and wattage equal, and then one is the same interface, you can mix. In general, the voltage is stable, the output wattage is the same, the notebook is basically no harm.
- Q: Delta VFD-F frequency converter how to adjust the number of poles
- Look at the 07 motor parameters, I VFD-F instructions need, then the mailbox sent
- Q: There is no inverter comes with simple PLC programming function
- The inverter is an AC speed control device, like DC speed control device, DC speed is to change the armature and excitation current, and it is the input AC through the internal circuit into DC, DC and then DC, the last DC AC output, this is the original 50Hz frequency AC can output other frequencies of alternating current, because the speed v is proportional to the frequency f, so you can set the frequency of the inverter to change the speed of the control motor. It does not have its own programming function. But there are servo drives, in fact, is a frequency converter, but can handle some of their own signals, usually from the servo motor on the encoder, and then control the servo motor to achieve precise control.
- Q: What is the difference between AC and DC frequency converters?
- L inverter air conditioner refrigeration system components: inverter air conditioner by the compressor, evaporator, condenser, electromagnetic four-way valve, electronic expansion valve, defrost valve, double capillary and other components (see Figure II), work, air conditioner Room needs, automatic control of the inverter output frequency higher AC, the motor speed to speed up, the compressor cooling capacity increased to achieve the purpose of rapid cooling or heating, on the contrary, when the room cooling or heating less, Compressor to normal speed or lower speed operation, therefore, inverter air conditioner has a continuous cooling capacity adjustment, making the room temperature fluctuations smaller. In the process of compressor operation, the microcomputer system controls the inverter compressor at the same time, controls the opening degree of the electronic expansion valve, maintains the proper refrigerant flow, and directly changes the flow of the refrigerant in the evaporator to change its state, the compressor The speed corresponds to the opening degree of the expansion valve, and the displacement of the compressor corresponds to the supply amount of the expansion valve, so that the degree of superheat is not so large that the capacity of the evaporator is maximized, so that the refrigeration system The most efficient control.
- Q: What is the maximum speed adjustable for a 4-stage motor with a rated frequency of 50Hz / 60Hz?
- Motor speed and frequency of the formula N = 60f / p In the above formula N - the speed of the motor (r / min); 60 - per minute (seconds); F - power frequency (Hirsch); P - pole pairs of motor rotating magnetic fields. China provides the standard power frequency f = 50 weeks / second, so the rotation of the magnetic field of the size of the theoretical diameter only with the magnetic pole. The number of pole pairs is large, and the rotational speed of the rotating magnetic field is low.
- Q: 55 瓩 4 pole motor with a frequency of one hour can save much electricity
- Such as: 55KW motor full load operation, 1 hour with 55 degrees of power (according to the motor power slightly different changes),
1. Manufacturer Overview
Location | Zibo, China |
Year Established | 2004 |
Annual Output Value | Below US$1 Million |
Main Markets | Middle-East America; Mid East; Northern Europ; Africa; Southeast Asia |
Company Certifications | CE;ISO |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Qingdao |
Export Percentage | 1% - 10% |
No.of Employees in Trade Department | 500-999 People |
Language Spoken: | English; Chinese |
b) Factory Information | |
Factory Size: | Above 50,000 square meters |
No. of Production Lines | Above 8 |
Contract Manufacturing | |
Product Price Range | High; Average |
Send your message to us
AC Motor Drive MV Variable Frequency Drive 4.16KV
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1PC pc
- Supply Capability:
- 10,000pcs/year pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches