• CM Series End Suction Centrifugal Water Pump System 1
CM Series End Suction Centrifugal Water Pump

CM Series End Suction Centrifugal Water Pump

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
5000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Horizontal end-suction Centrifugal Pumps Details:

Minimum Order Quantity:1 unitUnit:unitLoading Port:Shanghai
Supply Ability:5000 unit/monthPayment Terms:TT OR LCPackage:Wooden Case

Product Description:

Packaging Detail:standard export plywood case
Delivery Detail:15-20days

Specifications

1,Single-stage single-suction 
2,Axial suction centrifugal pump 
3,Back-pull-out design

Min inlet pressure

Min inlet pressure depends on NPSH +0.5m safety margin + gasified pressure. It should be re-calculated the inlet pressure if one of the following happens.

*The liquid is more warm.

*The flow exceeds the nominate value.

*Suction distnace is very long or inlet pipe is very long.

*System pressure is too little.

*Inlet pressure is low.

 

Typical application

*Clean, thin, non-corrosive, non-flammable or non-explosive liquid without grain or fiber.

*Water supply system

*Heat, air condition system

*Irrigating, farming

*Booster, constant pressure water supply

*Industry cooling, heater circulation system

*Firefighting, splitting system

*Industry transferring, drainage system

 

Construction

*Non-self-priming, single stage, single suction, horizontal, axial suction and radical discharge, pump body is fixed by base.

*Use bering cradle, which can orientate bearing, prevent from radical vibration, improve the rigidity of rotary part.

*Compacted shaft, use deep grove grease lubricated roller bearing.

*Connect pump and motro with semi-flexible coupling.

*Use standard wearable mechanical seal.

*TEFC motor, size complies to IEC standard, installation type B3.

*The dimensions is conform to ISO 2858

 

Specificaton

*Flow: Max 520m3/h

*Power:Max 160Kw

*Head: Max 160m

*Liquid temperature: -15°C - 110°C

*Working pressure: Max 16bar

*Inlet and Outlet diameter: Inlet diameter: DN50-DN200; Outlet diameter: DN32-DN150

 

Curve conditions

*Curves tolerance is according to ISO9906, Annex A;

*All curves are based on the measured value of constant motor speed 2900rpm, 2950rpm, 1450rpm or 1480rpm.

*The measurements were made with airless water at temperature of 20°C. The curves apply to a kinematic vis-cosity of 1 mm2/s (1 cst)

 

Features

*Back-pull-out design, without having to disurb pump body and pipelines when servicing.

*All the models only use 4 kinds of pump shafts and bearing cover, make parts exchangeable.

*Impeller is optimum design, inlet is enlarged, no whirlpool, deduct the water pump NPSH efficiently, which makes pump work stable with little noise.

*Casing and casing cover use wearing neck ring structure, which makes pump easy to maintain, makes parts work longer. The replaceable seal ring, makes pump work efficiently in a long time.



Q: How to adjust the flow of piston pump?
The oil pan with oil liquid through the suction port and the piston cylinder; from 180 degrees to 360 degrees, the piston cylinder volume decreases, so the oil liquid in the pan with oil discharged from the outlet of the liquid. The pump works continuously as long as the drive shaft rotates.
Q: What is the pump lift voltage? And how to suppress the pumping voltage rise?
The reverse voltage and torque electric torque instead, and the motor has strong braking torque, forcing the rotor quickly stopped, but usually AC-DC-AC converter is the main power AC/DC rectifier circuit is irreversible, and therefore can not return to the power grid, resulting in the main circuit of the capacitor voltage increases two that is called the pump voltage.
Q: What is the minimum continuous flow of a pump?
The minimum continuous steady flow can be obtained by test and, in general, the pump supplier will indicate(2) minimum continuous heat limited flow (.API) provides minimum continuous heat limit flow, which means the minimum continuous flow that the pump can maintain and that its operation is not impaired by the temperature rise of the liquid being pumpedMinimum continuous heat limited flow can be calculatedIn the formula, the Pe amount of the fixed axis power is.KW;P pump medium density, kg / m3;
Q: What should I pay attention to when buying a pump?
Two, the first choice of large and medium-sized professional manufacturers, and through the quality identification of relevant departments, the market credibility of the better models, but also to the professional quality inspection institutions consultation.Three, check the motor grounding device for electric pump, water pump and motor axis, the motor should be in a proper position is provided with a grounding screw, and the grounding screw are arranged near the ground; grounding device of small submersible pump should be reliable and grounding wire, grounding wire cables should have the obvious grounding mark the flag should be in use; the motor is not easy to be worn during the period. This is one of the important safety indexes of electric pumps.
Q: How to select metering pump head?
When it comes to metering pump heads, the usual problem is when they measure acid, chlorine, fluoride, and hydrogen peroxide. Due to the difference in concentration and operating temperature, it is difficult to determine the specific pump head material.
Q: The distance from the pump button to the ground
Yellow warning pop-up, indicating that the fire control room has issued alarm information, fire alarm controller (commonly known as the alarm host)
Q: What's the difference between non negative pressure and variable frequency water pump?
When peak water is used, the fluctuation of water pressure will be the same for customers! Because the key to the fluctuation of hydraulic pressure is the flow rate of the pump and the lift of the pump. As long as the flow of the selected pump is large enough, the tank is large enough, the lift head is suitable, and the pressure fluctuation is relatively small. And the selection of non negative pressure and frequency conversion pump group is not directly related. If the municipal tap water pressure and water sufficient (large enough diameter), the use of non negative pressure is better. If the municipal tap water pressure and water shortage, you can only use the frequency converter pump + water tank, no negative pressure can not be used.
Q: Shielding pump is the main drawback of electricity? How much does it cost more than an ordinary centrifugal pump? Is there any noise in the running of the canned pump? How much is it lower than the noise of the common centrifugal pump?
The graphite bearing lubrication medium, make the operation less noise and manual, reduce maintenance costs; in recent years, bearing material added with silicon carbide SIC, super hard, life is better than that of graphite bearing.The vertical structure can be installed on the pipeline like a valve, the installation is convenient and quick, and the motor and the impeller can be drawn out only when the utility model is used, and the pipeline is not needed to be removed.The utility model can be installed and run with a shock absorber or a damping pad, so that the pump is less noisy at running time.
Q: Rules for operation of centrifugal pumps
Working principle and process flowWorking principle: when the drive motor with high-speed rotating impeller, full of fluid in the pump body under the action of centrifugal force, was thrown from the impeller center to the outer edge of the impeller, in this process, the fluid energy, improve the pressure can, at the same time also increases the energy flow rate increase. The liquid from entering the pump impeller shell, the liquid flow gradually widened, the liquid velocity decreased gradually, which will be part of the kinetic energy into pressure energy, which further improves the static pressure of liquid, and liquid with high pressure in pressure pipeline. When the liquid from the leaves out when the impeller center creates pressure and low pressure than the out plane is big, under pressure drive, liquid is continuously from the center of the impeller suction, with the pressure of continuous discharge.
Q: Is the flow meter in front of the pump or after the pump?
After the pump, the reasons are as follows, before the pump, you pump fluid through the pump will produce negative pressure in front of the pump, negative pressure on the flow of the life of the impact, the pump will not, Suzhou first Chi meter

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords