• CDLK/CDLKF Non-selfpriming Multi-stage Centrifugal Pumps System 1
  • CDLK/CDLKF Non-selfpriming Multi-stage Centrifugal Pumps System 2
  • CDLK/CDLKF Non-selfpriming Multi-stage Centrifugal Pumps System 3
CDLK/CDLKF Non-selfpriming Multi-stage Centrifugal Pumps

CDLK/CDLKF Non-selfpriming Multi-stage Centrifugal Pumps

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
2000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1. Description of CDLK/CDLKF Non-selfpriming Multi-stage Centrifugal Pump
CDLK/CDLKF is non-self priming multi-stage centrifugal pump installed with standard motor.The motor shaft is directly connected with the pump shaft through
coupling.According to the requirement,the pump can be equipped with intelligent protector,which effectively protects pump from dry rotation,phase lack,overload etc.In order to meet the requirement of installation depth of the water tank or vessel,it is possible to install cavity body for changing length of the pump.Length for different number of stages is shown in the dimensions & weight table and the table of products supplying scope. 

 

2. Application of CDLK/CDLKF Non-selfpriming Multi-stage Centrifugal Pump

Electric spark 
Lathe 
Grinding machine 
Processing center 
Cooling devices 
Industrial clearing equipment 
Filtering system 

3. Performance range of CDLK/CDLKF Non-selfpriming Multi-stage Centrifugal Pump
Capacity: Q up to 55 m3/h 
Head: H up to 305m 
Temperature: T up to 120degreeCelsius 
Speed: N 2900/3500rpm 
Power: P up to 45kw 

4. Standard material of CDLK/CDLKF Non-selfpriming Multi-stage Centrifugal Pump
Stainless steel 304 or Stainless steel 316 
The pump head and suction & discharge head can be made of cast iron on request too. 

5. FAQ

1>.  Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2>.  Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3>.  How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.

4>Can your pumps mount Eff.1 motors

Currently, only on request though this will shortly be a CNBM standard.

5>Are your pumps protected against dry running?

No, unprotected centrifugal pumps are not generally designed for dry running. It is important to give us or your dealer as much information as possible about the system in which the pump is used. Inlet pressure, the type of liquid to be pumped, together with relative density, viscosity and temperature, for example, are required in order to allow CNBM to recommend the right pump with the right gaskets for a long operating lifetime.

6>How can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

CDLK/CDLKF Non-selfpriming Multi-stage Centrifugal Pumps

CDLK/CDLKF Non-selfpriming Multi-stage Centrifugal Pumps




Q: Know flow and lift how to calculate the pump power?
P: the density of refrigerant, when the working fluid is water, P =1ETA - pump efficiency, can not find desirable value =0.8N=30x (200/3600) x9.81x1/0.8=20.44 = 20 (kW)(that is, 20kW motors)
Q: The suction pump has a nominal suction range of 30 metersHow deep can a well be sucked?Well, sixteen meters,
Vacuum pump plus form must not reach a standard atmospheric pressure vacuum, so the general can absorb 8 meters is very good, and the self suction pump itself and loss, the horizontal self-priming pump can suck on basic 4~6 meters is very good, self-priming pump. Suction lift of 30 meters is purely in the Mongolian people, does not comply with the laws of nature, obvious anti science.
Q: What are the advantages and disadvantages of the pump control system and valve control system in the hydraulic system? How to choose in the project?
Valve control system is generally used for open systems, through the proportional valve or servo valve flow changes to control the motor or cylinder actuator action. The advantages of the system are energy saving, heat generation, and control accuracy. The disadvantage is that the system is complex and the cost is higher.
Q: What are the functions of a disposable infusion pump?
With the development of science and technology, more and more fields need to control the flow or velocity of fluid accurately. For example, the detection and analysis of micro chemical elements in chemical industry always need to control the flow accurately. In the field of health care, the flow and velocity of traditional Chinese medicine liquid must be controlled accurately.Venous transfusion is one of the most commonly used methods of clinical treatment. It is a common medication and treatment technique for nursing specialty. Clinically, appropriate infusion rate should be applied according to the drug and patient's condition. Transfusion too fast may cause poisoning, more serious can lead to edema and heart failure;
Q: The difference between diaphragm pumps, vacuum pumps and centrifugal pumps
The diaphragm pump and centrifugal pump refer to the structure of the pump, and the vacuum pump means the use of the pump. There is no comparability between them.Centrifugal is the sign of inertia of an object. As the umbrella turns, water droplets move out of the outer edge of the umbrella and are thrown out. This is what is called centrifugal. Centrifugal pump is designed according to this principle. The high speed rotating impeller blade drives the medium to rotate and is thrown out so as to achieve the purpose of conveying.
Q: What is the principle of a turbopump?
Turbine [turbine] is a machine that converts the energy contained in a fluid medium into mechanical work, also called a turbine. Turbine is the transliteration of English turbine, derived from the Latin word "turbo", meaning "rotating object".
Q: What are the main performance parameters of hydraulic pumps?
speedOperating speed is the actual rotation speed of a pump (or motor) at work.Rated speed is the maximum speed that can operate normally for a long time under rated pressure. If the pump exceeds the rated speed, the work will cause insufficient oil absorption, vibration and noise, the parts will suffer cavitation damage, life expectancy.Minimum steady speed is the minimum speed allowed for normal motor operation. At this speed, the motor does not appear crawling phenomenon.
Q: I want to know the concrete under 60 type pump performance, it is mainly the pump long spiral bored piles, such as the diameter of the pump, transportation distance, pumping height and so on, thank you!
Specification for concrete cylinders:Bore * stroke mm 200 * 1650Hopper capacity L 800Feeding height mm 1400Motor model Y2-280M-4Power kw 90Rated voltage V 380Rated speed r/min 1480Soft starter withoutHydraulic system open-loop
Q: Is the flow meter in front of the pump or after the pump?
After the flowmeter is placed in the pump, it is better to add a pressure tank or a buffer tank, so that the flow meter will work better
Q: How accurate is the metering pump?
In addition, when the oil supply is too large or the pipeline pressure rises unexpectedly, the volume of the liquid in the hydraulic chamber can be changed, thereby affecting the stability of the flow and reducing the metering accuracy of the pump. In order to solve the problem of how to stabilize the measurement accuracy of metering pump metering pump flow, how stable, the three valve device. The so-called actual refers to the combination of three functions including compensation, discharge and safety protection device or device supporting the hydraulic chamber, according to its action principle is different, is divided into automatic compensation and forced compensation two three valve device.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches