CDLK/CDLKF Immersion Multistage Centrifugal Pumps
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 3000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1. Description
CDLK/CDLKF is non-self priming multi-stage centrifugal pump installed with standard motor.The motor shaft is directly connected with the pump shaft through
coupling.According to the requirement,the pump can be equipped with intelligent protector,which effectively protects pump from dry rotation,phase lack,overload etc.In order to meet the requirement of installation depth of the water tank or vessel,it is possible to install cavity body for changing length of the pump.Length for different number of stages is shown in the dimensions & weight table and the table of products supplying scope.
2. Pump Application:
Electric spark
Lathe
Grinding machine
Processing center
Cooling devices
Industrial clearing equipment
Filtering system
3. Performance range
Capacity: Q up to 55 m3/h
Head: H up to 305m
Temperature: T up to 120degreeCelsius
Speed: N 2900/3500rpm
Power: P up to 45kw
4. Standard material
Stainless steel 304 or Stainless steel 316
The pump head and suction & discharge head can be made of cast iron on request too.
5. FAQ
1>. Can I get trained on CNBM products?
Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.
2>. Are your pumps cheaper than those of your competitors?
CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.
3>. How long is your warranty?
Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.
- Q: Know flow and lift how to calculate the pump power?
- The pump power (kw) ={9.61* flow (cubic meters per second) * head (m)}/.Where ETA is device efficiency, including mechanical, electrical loss and other factors, generally between 55%~80%. The smaller the pump, the lower the efficiency.
- Q: You'd better point out the details.... There are 2 best ways of experience and formulaCan you say a simple point, such as multi-stage pump, when the pump is higher than the motor, 30 wire is the next mouth how to do?
- Alignment methods and requirements:1, check two feeler dial gauge or flange coupling the parallelism, usually with clearance between the both ends of the side instead of difference, in the circumferential direction every 900 measure, the maximum and minimum gap gap difference (Ab) less than or equal to 0.3 mm.2, the coupling flanges outside the park up and down, left and right four position to check whether they are in the same line, C less than or equal to 0.1 mm.When looking for a positive C, it will affect (a - b), finding the right (a - b) will affect the C, to balance each other. It's easier for an unskilled comrade to find C (a - b) first, and then find a positive one. Through the adjustment of the motor at the foot of the gasket thickness (Ab) and meet the requirements of C.Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition.It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
- Q: I would like to ask, constant pressure pump set pressure 20Mpa, the actual load is 15Mpa, then the constant pressure pump outlet pressure? If it is 20Mpa, then where is the loss of 5Mpa? If 15Mpa, the constant pressure pump 20Mpa how to understand? In addition, the constant pressure pump pressure is defined when the flow began to reduce the point, or a sharp drop in flow after the point?
- The pressure loss is borne by the valve. Constant pressure pumps generally do not export direct load, unless you need this load response is very fast, then the maximum displacement of the pump work, so as to ensure the rapid response of the load.
- Q: Operating procedures for measuring pumps
- 3, discharge pipeline unimpeded.4, the pipeline should meet the positive pressure head, that is, in high flow suction conditions work.5, check the direction of the pump, strictly prohibited reverse.6. Check the oil level in the crankcase compartment. For multi cylinder pumps, check that the oil level has reached the required level.7 、 pump motor static grounding is good, meet the requirements.
- Q: Rules for operation of centrifugal pumps
- 3, start the pump, wait until the speed reaches the normal speed, slowly open the outlet valve, observe the ammeter at the same time, and control the current in the rated current range of the motor.4, the operation requires smooth operation of water pumps, no abnormal noise, no pressure fluctuations. The abnormal situation should be stopped in time.
- Q: What is the working pressure of the hydraulic pump in the hydraulic transmission system?
- The operating pressure of the hydraulic system depends mainly on the load. Generally speaking, the working pressure of the hydraulic system means the highest working pressure of the system. If the pressure is higher than the value of the equipment, the relief valve works to relieve pressure. The actual working pressure of the hydraulic system is determined by the load, which refers to the actual pressure of the hydraulic oil and can be read directly from the pressure gauge. The pressure increases with the increase of the load. You Li's balance can know: the thrust of the cylinder = the load, the thrust of the cylinder = the working pressure of the hydraulic oil, the working area of the cylinder, the working pressure = the load / the area of the cylinder.
- Q: Is the flow meter in front of the pump or after the pump?
- After the pump, the reasons are as follows, before the pump, you pump fluid through the pump will produce negative pressure in front of the pump, negative pressure on the flow of the life of the impact, the pump will not, Suzhou first Chi meter
- Q: Centrifugal pump flow, why can be adjusted through the outlet valve? Can the flow of the reciprocating pump be adjusted in the same way?. Why
- Reciprocating pump is a positive displacement pump, the volume change of flow is the unit of time, constant flow speed constant, can not rely on increased resistance to change the flow resistance increase is only leaked, only small changes in flow.
- Q: No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same, how to choose the control cabinet?
- Non negative pressure variable frequency water supply means no negative pressure superposed water supply equipment. When running, it is connected directly to the water supply pipe. Always test the pressure of tap water pipe network and water supply pipe network pressure control system, when the water pressure is lower than the pressure required by the user, the frequency conversion device based on water automatically control the pump speed through the steady flow compensator of water balance, maintain a constant pressure water supply. In the multi pump system, the control system can automatically dispatch the water pump according to the water consumption. It can balance the working time of the pump and ensure the pressure of the water supply. When the water supply pressure satisfy the required pressure, the system automatically stops the pump by the external water supply pipe network directly. CJWFG-DYG non negative pressure superposed water supply system:
- Q: What is the difference between centrifugal pump and self suction pump? Which is better?
- If the centrifugal pump in full before the start of the shell of the gas, then start after the center of the impeller was thrown in the gas can not be large enough to form the vacuum, so that liquid in the bath can not be sucked, so the centrifugal pump to start before using foreign liquid in the pump housing space filling
Send your message to us
CDLK/CDLKF Immersion Multistage Centrifugal Pumps
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 3000 unit/month
OKorder Service Pledge