• CDL/CDLF vertical multistage pump System 1
CDL/CDLF vertical multistage pump

CDL/CDLF vertical multistage pump

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product introduction:
CDL/CDLF is a kind of vertical non-self priming multistage centrifugal pump, which is driven by a standard electric motor .The motor output shaft directly connects with the pump shaft through a coupling. The pressure- resistant cylinder and flow passage components are fixed between pump head and in-and outlet section with tie-bar blots. The inlet and outlet are located at the pump bottom at the same plane. This kind of pump can be quiped with an intelligent protector to effectively prevent it from dry-running,oul-of-phase and overload.

Application:
CDL/CDLF is a kind of multi-functional products.it can be used to convey various medium from tap water to industrial liquid at different temperature and with different flow rate and pressure.CDL type is applicable to conveying non-corrosive liquid, while CDLF is suitable for slightly corrosive liquid.
1 .Water supply: Water filter and transport in water works, boosting of main pipeline, boosting in high-rise buildings.
2.Industrial boosting: process flow water system, cleaning system, high-pressure washing system, fire fighting system.
3.lndustrial liquid conveying: Cooling and air-conditioning system, boiler water supply and condensing system, machine-associated purpose, acids and alkali. 4.Water treatment: filtration system, reverse osmosis system, distillation system,separator, swimming pool
5.Irrigation: Farmland irrigation, spray irrigation, dripping irrigation.


Work Conditions:
Thin, clean, non-flammable and mon-explosive liquid containing no solid granules and fibres.
Liquid temperature: Normal temperature typei-15℃ -+70℃
Hot water type:+70℃ -+120℃
Ambient temperature: up to+40℃
Altitude; up to1000 m


Q: Piston filling and peristaltic pump filling which precision is high?
If the unit area is large, the accuracy of the plunger is certainly not high. The peristaltic pump is used by means of extrusion roller extrusion pump to promote the solution, this also depends on the unit cross section size, the same motor accuracy is very important.
Q: What is a solution pump?
2.1 advantages of canned pumps(1) fully enclosed. There is no dynamic seal in the structure. Only the static seal in the outer shell of the pump can be made without leakage. It is especially suitable for transporting flammable, explosive, precious liquids and toxic, corrosive and radioactive liquids(2) high safety. The rotor and stator each have a shielding sleeve, so that the rotor and stator of the motor are not in contact with the material, even if the shield is broken, it will not produce the risk of leakage and leakage(3) compact structure and small footprint, the pump and motor is a whole, disassembly and assembly do not need to find the center. The base and foundation requirements are low, and the daily maintenance workload is low, and the maintenance cost is low
Q: What are the characteristics of a pipe shield pump?
Two, reverse circulation type of shielding pump, its bearings, lubrication, cooling and motor cooling fluid flow direction and the basic type is the opposite. The main characteristic of reverse circulation pump is that it is not easy to generate cavitation. It is suitable for conveying liquid which is easy to vaporize. Sometimes it is also called "easy to vaporize" type. Three, high temperature medium temperature of up to 450 degrees. The cooling water jacket is usually added outside the shielding motor, and a cooling sleeve is added to the outer circulation pipe to cool the high temperature circulating liquid to reduce the temperature of the motor and the bearing. In the case of less power, some manufacturers do not use cooling liquid, but the outside of the motor is equipped with fins and the special winding to adapt to the working conditions, the use of temperature generally can not exceed 400 degrees.
Q: Is the diaphragm pump and the drain pump one?
Therefore, the need to play a liquid discharge pump, if the medium is corrosive liquid, high viscosity, volatile, flammable, highly toxic liquid, you can choose diaphragm pump. Conversely, the general liquid, there is no special requirements, you can use the general centrifugal pump to reduce costs.
Q: What's the pump? Where can I use it?
A pump is a machine that transports liquids or pumps liquids. Pumps are ubiquitous in life. They can be used to transport liquids such as water, oil, acid and alkali, emulsions, suspensions and liquid metals, as well as liquids, gas mixtures, and liquids containing suspended solids.
Q: What does "efficiency" mean in a water pump catalog?
General pump efficiency is 60% ~ 85%. high efficiency of the pump, indicating the same work, the pump consumes the lowest energy, and vice versa
Q: Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
The direct connected pump impeller is directly mounted on the motor shaft, and the non direct connected pump and motor are two shafts, and the two shafts transmit torque through the coupling
Q: Which nuclear submarines use the shaftless pump technology?
The team led by academician Ma Weiming of China is now carrying out the research on this technology and has achieved initial success.. This technology is expected to be applied to the next generation of domestic submarines.
Q: Metering pumps related matters
2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
Q: Because the water pressure of the booster pump is not enough, it can not work automatically. It can only be operated by hand. It is inconvenient to use.
One possibility is the automatic type household booster pump used for a period of time, automatic failure phenomenon, it is mainly stainless steel and other metal products in pipes, long-term precipitation to shut off the power supply after unloading, unscrew the top screw, remove the plastic sheet to be cleaned, and then, according to the original reset, the normal debugging. Can be re used. But that's not why if your booster pump isn't working properly all the time.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches