• Bright and Soft Surface Stainless Steel Wire System 1
Bright and Soft Surface Stainless Steel Wire

Bright and Soft Surface Stainless Steel Wire

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
5 m.t.
Supply Capability:
100 m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

stainless steel wire
1. good quality
2. best and competitive price
3. professional services
4. fast delivery

 

stainless steel wire
1. good quality
2. best and competitive price
3. professional services
4. fast delivery

 

Specifications

1)stainless steel wire from 0.1mm to 16mm,manufacturing all kinds of wrie,for exsample,EPQ,WEA,ANI,RED,ROP,etc.
2)Grade200 ~600

1)stainless steel wire from dia.0.1mm to 16mm(0.004''-0.630'')

2)grade: 300 series,200 series,400series

3)item:EPQ wire,weaving ,braiding wire,cold heding wire,spring wire,redrawing ,annealing wire,shaped eire,welding  wire,CD bar,CG bar.

4)Electro polishing quality wire, weaving wire,braiding wire,Cold heading wire,spring wire,Redrawing wire,annealing wire ,shaped wire,welding wire,CD bar,CG bar

Dia mmMaterialExecution surfaceTemperApplicatione.g
1.00-7.00304,316,201CU,430LXJ1,410 .etcEPQ wire-Eletro Polishing Quanlity bright/dullsoft,1/4hard 1/8hard---in manufacturing bicycle fittings,kichen,and sanitation tools,good shelf···Bicycle batket,pet cages.grill racks.
0.11-8.00316,321,309s 310s,314,304.etc.Annealed wire,Weaving wire,Braiding wirebright/dullsoft···as requestuse in weaving general nets,heat resistance belts,also widely uesed for chemical,food proceesing,kitchen utensils```nets,belts
3.00-11.00304HC,302HQ,316LCU,201CU,204CU,200CU,420,430Cold heading wire/Annealed wirebright/dullsoft,hard···as requestuse for various kinds of fastener manufacturing precision screws,bolts and nuts ,rivet,nail.stable,pins
1.0-7.0302,304,321,631J1,347Spring wirebright/dullharduse for rolling various precision springssprings
0.11-16.00304,304L,AISIL304L,302,304H,321,316 Redrawing,Annealing wirebright/dullas requestgood elongation generatrix for other manufacturefine wire,acupuncure wire fine sping wire
0.11-16.00201,202,304,303CU,shaped wirebright/dullas requestBeing apt for forming and machingwiper wash,watch bands,filter,brassiere wire
0.89-12.00 ER308,ER308LSI,ER309,ER316L,ER410Welding wireas requestas requestwith steady chemical compositions,used in welding and manufacturing semi-finished of Metal-insert gas arc welding wire etc.
1.0-16mm Max.5m304,303,303C,304ES,Round Baras requestas requestused chiefly on production of stainless steel aixs and hardwares.
Q: no power to brown trailer wire
press the pedal to the metal.
Q: Or can stranded wire of the same gauge be subsitituted for solid wire without any consequences? The reason I ask is because its for a massive 4kJ capacitor discharge circuit, and I need all the energy delivered to the power coils im using, cant afford to have much leakage inductance.
Stranded wires have slightly higher inductance than solid wires, but this is noticable only on transmission lines and larger conductors. if you are only using a short conductor, i don't think the inductance of the wire will affect the system, unless the wire is coiled.
Q: I am replacing my garbage disposal. I have black, white wires and a black/yellow wire. How do I connect this black/yellow wire. Is this a hot wire as well?
if you do not have a circuit tester then it is time to buy that $3.00 item === it is a little glow light that will be a dim light at 110volts and a brighter light at 220volts -- has two wires with metal ends and can help you with the disposal and wall sockets or other connections ... any hardware store has this tester. NOW ... we deal with the blk/yellow wire -- it is possible that it is a ground, or it is a hot wire or it could be to a GFIC [[ ground fault interrupter circuit ]] that is in the home panel -- OR -- who knows about the electrician that was the original wiring person --- most I have ever seen in wires to a disposal is two [2] wires a blk and a wht == this is a common mistake that most DIYers make .. they do not take the time to make full investigation and label wires as they take things apart .... get the tester as that is the cheapest way to solve also look at panel for the GFIC or call an electrician ,,,,,,,,, respectfully,,, XTX
Q: where can i buy these type of wires (copper insulated wires)??
Hi i would be sure to use insulated wires in most situations, the only time bare wires are considered is when there is absolutely no chance of any one touching them and the only time that situation ever occurs is in the case of an antenna for receiving a radio signal. the wire should as high of the ground as possible so no one could touch it.
Q: How can I investigate the resistance of wire and how it changes with the length of the wireCheers
If you don't have a multimeter, you can probably see the effect of resistance with a flashlight bulb and a small battery (AA or AAA, etc). Get a spool of wire, needs to be coated/insulated wire. Connect the bulb to the battery with the shortest wire possible. See how bright the bulb is. Then, connect again using the entire spool of wire (hopefully you can get at both ends of the wire while it is still on the spool). The bulb will be dimmer because the voltage at the bulb will be reduced by the resistance of the wire (resistivity per unit length X the length of wire). If the length of wire on the spool is too long, the bulb will not light up at all.
Q: hi i have 2000 prizm the wires coming out of car doesnt match the colours of stereo wires does and body knows the wiring coding for car to sony cd player thanks
this the wire-hares that you need and the dash kit. 70-2003 wiring harness 99-3413 dash kit if you have any more question you can IM me any time. KS AUDIO OWNER KIM
Q: the ground wire came loose and touched the power wire for a second and created a big spark . the fuses aren't blown what else can i check or fix because the amp won't turn on now.
Did you check the fuse at the battery, that is the one that would have blown.
Q: Thermostat has two red wires two black wires. The baseboard has one red one black wire.
That thermostat is a two pole switch. (It opens both lines). Just follow the color codes. Your incoming 'line` might be a two wire run, (Black, White, + Gnd.). In this case just treat that white as a 'Line' wire, (Red). It Should be marked, but sometimes they don't do it. Black, (Line) to Black, T (Stat). Black (T Stat), to Black (Heater). Same for the Reds. The T Stat. should be marked 'Line' 'Load' if it matters with that unit. Some Cautions: 1. Don't try to work it 'live'. 2. If the line wires are black white, be sure that you have a 240V. circuit. -(Two pole breaker). 3. Coil your 'pigtails' (connecting wires), so that the insulation doesn't contact the hot parts of the heater.
Q: Okay, magnet wire is coated with some red fancy insulation. Is that just an enamel?If so, enamel coated copper wire magnet wire would be the same thing.I want to build a loudspeaker. This what I need?Are the coils used in loudspeakers the same ones used in inductor coils?One interesting question,When Faraday was experimenting with the effects of magnetism on electricity, how in the hell did he figure out the magnetic field increased with the number of turns of copper in his coils!I'm only assuming Faraday didn't have insulated copper wires.Lmao, if they aren't insulated, how in the heck is he suppose to know how much the field is increased. The Coil would just become a big conductor lol
Today we always use magnet wire from inductors, transformers and speaker, but Faraday didn't have any so he just used insulated wire. He was smarter the you and me, so if we know you need insulated wire, so did he.
Q: Say you have a 5 cm current wire carrying 10 A going from left to right. Directly 1 c.m below the left end of this wire is a long wire that is perpendicular to the first wire and goes out of the page. What is the net force on the 5 cm wire?I've tried using F=ILB with the I of the first wire and the B of the second wire.
I didn't read the question so I was carefully working out the force. The wire is perpendicular to the first wire, so using the right hand rule you discover that the field it creates is PARALLEL to the first wire at this left end. The magnetic force is caused by the component which is PERPENDICULAR to the wire which is in fact zero. So there is no magnetic force at this point. As you move along the wire you get a diminishing amount of magnetism caused by the wire which is going out of the page but that field has a component which is DOWN the page. Therefore that part of the wire experiences a force which is into the page. ( take your right hand, put the thumb along the wire pointing to the right, the fingers point down the page, the palm points into the page which is then the direction of the force) I would be surprised if you were required to work out the magnitude of the force in this context. You can't use F= ILB because both the magnitude and the direction of the field varies at different points along the wire. If the perpendicular wire had been directly below the middle of the other wire there would have been no net force. If you were of a level where working out the force was appropriate you would need to set up the formula for B at various points along the wire, taking the vertical component only and integrate this over the range from 0 to 5 cm. Not a trivial mathematical task.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products