Black Round Wire for Binding Rebar Tie Wire

Black Round Wire for Binding Rebar Tie Wire

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
5 m.t.
Supply Capability:
50000 m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specification

Material:
Galvanized Iron Wire
Cross Sectional Shape:
Round
Application:
Construction Wire Mesh
Type:
Galvanized,U Type Wire,Loop Tie Wire
Wild in Width:
1.1M
Surface Treatment:
galvanized
Metal Wire Drawing:
Cold Drawing
Status:
In Hard State
Thickness:
Metal Thick Wire
Galvanized Technique:
Hot Dipped Galvanized,Electro Galvanized

Black Round Wire for Binding Rebar tie wire

Dia of the black eounf wire :BWG8-BWG22 
Material of the black round wire :Low carbon steel 
MOQ:1 ton 
sample: free sample 

black round wire for binding rebar  /black binding wire  

 

Material:Low carbon steel Q195

 Features of the black round wire of rebar tie wire  soft tenacity, strong tensile strength, corrosion resistance, folding resistance is strong, colour and lustre is uniform

 

Production Process: the Q195 wire rod drawing model into the black iron wire, through 1000° high temperature firing, black iron wire after annealing treatment, soft wire, can increase the wire tensile degrees.

 

 

Tensile strength: 350mpa-380mpa

 

 

Specification: # 14 # - 36, also can be customized according to customer's requirements.

 

 

Packing: 25 kg per roll, usually inside plastic outside white woven bag or burlap.

 

 

Usage : can be used to weave silk screen or cut into wire cutting, used in construction, industrial arts, etc.Soft wire after annealing, increased flexibility, building tie wire.Binding reinforcement effect is better.
 

Packing and shipping details :

Black Round Wire for Binding Rebar Tie Wire

  
 
Black Round Wire for Binding Rebar Tie Wire
    

 

Gage No.
 
BWG(mm)
 
 
Metric(mm)
 
 
8
 
4.191
 
4.00
 
9
 
3.759
 
4.00
 
10
 
3.404
 
3.50
 
11
 
3.048
 
3.00
 
12
 
2.769
 
2.80
 
13
 
2.413
 
2.50
 
14
 
2.108
 
2.50
 
15
 
1.829
 
1.80
 
16
 
1.651
 
1.65
 
17
 
1.473
 
1.40
 
18
 
1.245
 
1.20
 
19
 
1.067
 
1.00
 
20
 
0.8886
 
0.90
 
21
 
0.8128
 
0.80
 
22
 
0.7109
 
0.70
 


Q:I NEED TO CHECK IF A WIRE IS GOOD ON A FITNESS MACHINE. HOW DO I KNOW IF ITS GOOD? WHAT SHOULD THE OHMS BE?
any wire, unless it is very long or very thin, will measure zero ohms on an ordinary ohmmeter. But check for continuity does not completely check a cable. Most cables have several conductors in them, so you need to check each one end to end, and check resistance between the wires. Between them, it should measure open or infinite ohms. But the cable could still be bad. Tell us the details please. .
Q:what size wiring should i use to wire a plug in for a dryer?
if the dryer rateing plate says 220 volt 30 amp you can use # 10 stranded wire/ romex 2 colored wires and 1 ground (bare) or insulated green wire.
Q:I need to use quot;insulated copper wireor quot;enamel covered copper wirefor a project...I used normal copper wire and obviously it failed. Can this be like normal copper wire with plastic/rubber coating around it, similar to electrical wire? Or is it something special?
yes if it has plastic on it, it is an insulated wire
Q:I own a 1990 Toyota 4runner 6cyl, 3L. it had a few performance issues when i bought it. ( just didnt seem to have any power idling at around 200), so before spending money on expensive items, i figured spark plugs, wires, cap and rotor. So i just changed the spark plug wires today, and immediatly the truck was runnin much better idling at 800-1000 , about 5 minutes into driving, the problem started again, i parked the truck, it was idling at 200-300 again, opened the hood saw a bit of smoke coming from one of the wires, so im hoping and assuming it was just smoking because the wire was touching a hot surface, i can hear a bit of a clicking noise that i dont remember hearing before, almost like a spark. what could cause the sudden problem, is it possible the wires could be connected to the wrong spark plugs ( i replaced the old ones one by one, so i know i didnt connect it wrong) any tips would be great
The wire burned on something hot and is arcing to ground. Replace it and use a wire loom to stand it away from the problem surface. That clicking sound is the arc.
Q:Three parallel wires are each carrying a 4A current. ; wire A) is 6 mm from wire B) which is 3mm from wire C); The current in wires B and C are out of the paper, while A is into the paper. What is the magnitude and direction of the magnetic field halfway between wires A and B?I have tried using Biot-Savart Law but keep getting it wrong can someone please help? I also have an equation for two parallel wires but how do I relate it to two?
SO YOU HAVE TWO POINTS ON PAPER HAVING DISTANCE 2d. megnetic field zero will be on the mid point of this line. (there will be many points where the megnetic field will be zero but THERE IS ONLY ONE POINT ON PAPER)
Q:I have a wire coming up from my basement that has 3 wires (red, green and yellow). I want to connect cat5 wire to that (twisting the wires together) and run the cat5 to an RJ45 box. What's my diagram going to look like?
the wall plate has been terminated at TIA 568 b so that you only want to be sure out in the journey that your modem is waiting for the cable as TIA 568B or TIA 568A.. there's a huge difference because the pairs are terminated in a unique way. seem at reference I appropriate .. i do not use those type of wall plates I perfer to apply the punch down form and then punch them down as TIA 568B .. i have self assurance the issue you're having is interior the way the wall plate is operating.
Q:What are some of the basic advantages of twisted pair wiring?
Less interference.
Q:What fabric is the wire made of? What are the advantages and disadvantages?...
The metal filament has special rigidity and variable bending, so the fabric has special variable shape memory wrinkle effect, and the fabric has the function of radiation protection, antistatic and other health concepts.
Q:On a 1985 Dodge D-250 there are two wires coming off of the starter the thicker off the two goes two the starter the smaller one has been cut up by the battery. I was told the truck was running last week and all they were doing to start it was touching it to the positive post with the other wire but when I do this the starter just clicks. I pulled the starter and had it tested and was told its good and I have power to the cab I.e. lights and all so were does this wire go and what do I need to do to start this thing
the starter has two wires to it. one os from the battery positive and it is a decent sized cable. the other is a smaller wire that comes from the ignition switch really. that little wire is what you need.
Q:One hundred meters of a certain type of wire has a resistance of 7.2 Ω. What is the resistance of 2.5 m of this wire?I figured it would just be a proportion so (7.2 * 2.5) / 100 = 0.18 Ω. Is this the correct approach?
Resistance of a wire : R = ρ * L/A R ∝ L ( L = length of the wire) R' = L'/L * R = 2.5/100 * 7.2 = 0.18 Ω. Yup, your answer is correct

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches