• Arcamm Roofing Insulation & Eavestrough - Double Side Aluminium Foil Laminated to Fiberglass Cloth System 1
Arcamm Roofing Insulation & Eavestrough - Double Side Aluminium Foil Laminated to Fiberglass Cloth

Arcamm Roofing Insulation & Eavestrough - Double Side Aluminium Foil Laminated to Fiberglass Cloth

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Double sided aluminum foil embed fiberglass plain fabric, aluminum foil jacket

1. Description & Keyword:

Alkaline-resistant, fiberglass fabrics as core bringing us a stronger laminates with superior chemical resistance, high temperature endurable; meanwhile absolute environmental, FGS701 is upgraded from FG701 by adding another layer of aluminum foil.

2. Structure & Benefits:

Choose inorganic raw materials, FGS701 will not influent by moisture and microbiology.

3. Application:

[1]. Pack the air-conditioning outlet

[2]. Could be cut to wrap around the glass wool in different sizes for inserting between the main body and the inner body of the subway wagons, for insulating against temperature and sound .

4. Dimension/Size

[1]. Roll width: 30mm-1200mm

[2]. Roll Length: no less than 50m (Special seizes available upon request)

[3] . Core I.D.: 3"(76mm+/-1)

5. R&D

We are studying fire/flame retardant adhesive for improve quality of our products to bring you a safer environment and protect your life.

6. Similar products guide

FG701: single layer of 7micron aluminum foil was applied to FG701

FG701T: self adhesive tape, easy to install, because of the application of pressure sensitive adhesive, two types we supply: one could endure temperature from -10degree centigrade to 60DC, another one could standing from -10DC to 100DC.

Q: Should a two story home have insulation under the roof in the big closets ?
Hell yes it should. A lot of contractors skimp on insulation though. Every singe area in your attic under your roof needs fiberglass insulation or you will lose heat and air and your electric bill will be higher. Heat rises and u will lose it fast in the winter if there is just one small spot without it.
Q: My home is shaped like a square box. The four corners of the upper level have the roof pitch from the gables protruding into the rooms. The attic has no insulation and I need to insulate it. There is access from the attic to look down into the wall/ceiling that protrudes into the room. I can insulate the attic myself but the surface area of these protrusions is rather large. What would be the best way to get insulation down in there? Shoot the insulation in and poke it with a stick to make sure there is good coverage down in the wall space? The opening is about 6 inches high.Thanks.
Loose fill cellulose can be blown into your attic. I don't know if I understand the protrusions that you are describing but if you can freely blow the cellulose fiber into this space it should serve as a good insulation. You don't want to poke it in with a stick because you don't want to compress it. If you cannot blow this product directly into the space, you would be better off stuffing it lightly with fiberglass batting. Just don't cram it too tightly. It needs to be loose to be most effective.
Q: In a house, it looks like an addition, that now is the kitchen , it feels HOT, it doesn't seem to have a very good insulation on the roof at all, the ceiling is already low, so, what can be done on the outside to give it more insulation?, i don't care what it is i just want to give it a GOOD insulation, the roof is flat and to shingles. Any IDEAS? , thanks!
Sorry but there isn't enough info to give a good answer...is there space between the ceiling and the roof to add insulation...there may be enough insulation but no ventilation in the area directly under the roof (atic area) If there is not enough air flow in this area the temperature will skyrocket thus heat the kitchen AND the shingles will deteriorate very quickly.If you still need to add insulation the best way is to put sloped roof (if possible)and add insulation in the space created or you can use foam insulation and re roof ..make sure you seal between the wall system and new insulation and whatever method make sure to allow air to flow under the roof (both inflow and outflow)
Q: do i leave air gap in attic roof for insulation?
The best way to set up an attic is to put a vapor barrier under the rafters (before nailing on the gyproc), then put the insulation (fibreglas batts) between the rafters to full depth (10 or 12 inches). Soffit vents are installed under the eaves at the sides of the roof, and gable vents are placed near the peak of the roof at the ends. This allows for airflow resulting from convection, particularly important in the summer months to remove heat buildup in the attic. If the insulation is adequate, it will not only isolate this heat buildup from the inside of the house in summer, but will prevent heat loss to the attic in winter. (The airflow in winter will be minimal, but will remove any moisture/condensation that might collect otherwise.)
Q: what's the best insulation for ceilling for house with semi flat roof?
The pitch of your roof has nothing to do with the kind of insulation you should use. I recommend a fiberglass insulation that is at least 6 inches thick, the more you put in the better.
Q: Why would you not insulate between the rafters in an attic? I see a lot of houses with no insulation on the inside of the roof.
as long as the attic floor is insulated that is all you need. The insulation will keep the area below it warm. If you insulate the rafters then the attic stays even warmer while the area below not so much.
Q: Have a patio with metal roof, gets very hot during summer. Will Great Stuff insulate and stick to hot roof during summer? Thanks
I don't think Great Stuff foam insulation is meant to be applied in the manner in which you need. It is used to fill gaps and cracks, not be sprayed out in thin coats. whenever I've used it in the past, I found out it did not like to be spread out, or "worked".
Q: I've found lots of building forums and general "building advice" columns that go over very high-level pros/cons to choosing roofing material and insulation options, but I want a site where I can see hard costs of ordering each of the materials so I don't have to call up a ton of contractors or dealers. Does such a comparison site exist? Everyone offers quotes, but that takes too much time to apply for quotes to every dealer.I'm specifically interested in knowing what green options I can afford (cotton batting vs. formaldehyde-free fiberglass, etc.).
i could propose the felt. I rather have heard the two execs and cons with regard to the extra moderen man made underlay, and that i'm no longer inspired. I consistently get rid of the previous roofing, positioned #30 felt down, positioned a 1x4 batten down, and positioned my steel on that. I additionally want the three' huge roofing
Q: What is the difference between roof and loft insulations?
Potentially that the roof itself is insulated on the underside. A loft insulation could be that the base or floor of the loft/ attic is insulated. Otherwise, I'm not sure.
Q: We bought a house and put new metal roof on over the shingles. (first please don't say, this or that should have been done, just what I can do now) Any how, we have put a lot of money into the house, roof, all new electrical, all new plumbing, etc., I had to make the house in a "living in condition" with a low budget. ............ the house does not have insulation in ceilings, this has to be done next summer. (budget) Any how, the metal roof has condensation under it, only in the ridge vent area. This drips a little and I need to fix it. Now, I know that insulation wouldprobablyy fix this, but we don't have the money right now, so I need help on what to do? Is there anything that with a $100 to $200 budget can be done? I have searched a little, and maybe use a "spray-on"insulation help? The area is where the gap is at the peak and where themetall overlaps the ridge vent. (I thinkthat'ss what it's called)Thank you! :)
The problem might be resolved by venting the attic. You need to have an air exchange in the attic to prevent condensation.