Bubble Insulation Benefits:
Reflects 96% of radiant heat
Non-toxic / Non-carcinogenic
Does not require protective clothing or respirators to install
Durable and lightweight
Does not compress, collapse or disintegrate
Vapor and radon retarder
Easy to cut and install
Permanent and maintenance-free
Does not provide a growth medium or nutritive value for fungus, insects, or rodents
Does not support the growth of mold or mildew
Not affected by moisture or humidity
Lowers heating and cooling costs year round
Bubble Foil Application:
Metal & Steel Buildings
Homes
Roof Underlayments
Cathedral Ceilings
Crawl Spaces
Hot Water Heaters
Basement Walls
Floors
Garage Doors
Concrete slabs
Driveway snow melts
Pole barns
Post frame buildings
Poultry barns
Animal kennels
Temperature sensitive storage areas
Air Bubble Foil Insulation Tech Data:
Material Structure: AL/Bubble/AL | ||
Bubble Size:D10mm*H 4mm(10*2.5/10*4/10*6/20*7/25*10)choose the bubble size | ||
Bubble Weight:0.13kg/m2 ( can be customized ) | ||
Roll Width:1.2m (lenth can be customized) | ||
PROPERTIES | TEST DATA | UNIT |
Thickness | 3.5-4 | mm |
Weight | 250 | g/m2 |
Emissivity | 0.03-0.04 | COEF |
Thermal conductivity | 0.034 | w/m0 |
Apparent Density | 85 | kg/m3 |
Reflectivity | 95-96 | % |
Water Vapour Transmission | 0.013 | g/m2kpa |
Corrosion | doesn't generate | |
Tensile Strength(MD) | 16.98 | Mpa |
Tensile Strength(TD) | 16.5 | Mpa |
- Q: I'm thinking of converting my brick walled corrugated iron shed into a changing room for winter hot tub use. I was advised by a friend that the first thing i should do is insulate the roof using glass fibre insulation (the yellow fluffy stuff in the loft) and a simple Plywood ceiling but im not sure how i would stick it to the existing roof (dimensions 170cm x 147cm). So..... how should i insulate the roof of my future changing room????
- If the roof has joists, which I imagine it would, you would put the bats of insulation into those spaces... these can then be stapled into place or if that isn't possible, you can run a wire between the joists to hold the bats in place. If using faced insulation be sure to put the paper side towards the warm area (inside) to prevent condensation.
- Q: So I'm renovating an old farmhouse with a metal roof and there is no insulation in the attic. I was up in the attic checking for leaks since we just got some freezing rain and it is currently melting I thought now was the perfect time to check. I found no leaks but I did notice the roof was sweating with noticeable beads of water in many places and many of the 2x4's that act as the frame were damp, although none were rotted (I found that odd as the house is approx. 140 years old and those are the original 2x4's. I could tell that the attic does have vents so I guess it dries out before rotting or mold occurs.. but makes me wonder if I put down some roll-in faced R-30 Owens Corning Insulation and then add a plywood floor over top if everything will be fine.. or not so fine..
- Is the attic floor completely uninsulated now? You need a single layer of vapor barrier between the living space and the attic space. This is often done with faced insulation rolls. A vapor barrier between the living space ceiling and your new insulation may be enough all by itself to prevent the condensation from forming. If there's existing insulation, you'll have to pull some up to check for a vapor barrier. If there's already a vapor barrier, you can add unfaced insulation. Never put in two vapor barriers with insulation between them.
- Q: We have recently moved into a house in Australia with a tin roof. There is a layer of 5cm batts on the rafters in the roof space, but the temp is 10-15 degrees C higher up there than in the house (with all the windows and doors open). I don't want to get air-conditioning, is there another way to insulate the roof and cool the house?
- like they said ventilation is the answer... you allready have a radiant barrier ( metal roof ), now get the heat out. a rigge vent would be best with plent of open soffit all the way around the perimeter. if you're in a dry climate, a humidifier will work as well as an a/c, but much cheaper! give measurments in feet & inches... what do you thing, some one from france is going to help you?
- Q: Hello, this is quite an ordeal I've got. I am renting a cabin that has galvanized metal sheets as roofing. These are of course nailed into large wooden beans that run all acrooss.The owner and I made a deal, that deal is that I will put up insulation on the roof. However, she wants to put (i don't knw what they are called) big rectangular styrofam blocks (about 3x9 feet long). She wants me to cut them up to a width where they will feet in between the wooden beams and somehow secure them on. My idea of securing them is by nailing a plastic covering over them. but I am unsure about how to do the rest. How will i get the blocks to stay put if i cannot nail them? is there a better and CHEAP way to do it?As of now, if you look up you see the wooden beams and the tin metal roof. She wants it to be insulated and not visible.
- Without important points related to what's between the roof and the ceiling below it, regardless of if it can be a one story or two story constitution; fast fix maybe relative? If for illustration,,,and that i have got to anticipate this, that some insulation exists in an attic, crawl space, and so forth. Then absolutely that must be checked for an "R" ranking, and decide to add or change. Possibly the "venting" variety fixtures usually mounted are either absent of now not strictly realistic. Perhaps historic time approaches like attic exhaust fanatics perhaps employed? What is the constitution of your roof to the point the place under roof vents, soffit and facia exist? Without figuring out the substance of the structure, IE: Block, body, and so forth., you could try to check if correctly the partitions are insulated, and strive exchange in that also. A extra ordinary repair, however absolutely now not rapid can be to have timber blocking and shading where the solar does strike the apartment. Windows within the direction of the solar can be tinted, as they provide no, actual insulating properties. Awnings over windows on the exterior might support in small measure. I are living in primary FL. And happen to very so much experience sun and warmness, however certainly it could actually reason financial budgetary issues. There are numerous methods you could attempt to block the sun, or insulate the apartment, and all is also legitimate, even along side the others, however speedy is, as I mentioned, relative to how much effort and money you have got to put into the effort. Steven Wolf Went back to CEMENT in the original. Is the ROOF cement as well? Is this in fact a "apartment" or apartment constructing? Is the "cement" "POURED" concrete panel building, or is it "block"?
- Q: This is blocking airflow and I'm having it removed after I bought the house. There is already insulation on the attic 'floor'. This is double insulated and is not correct. Why would anyone do this?
- No building codes back then, and maybe he was thinking about putting an extra room up there then you would have to insulate the rafters also
- Q: Why would you not insulate between the rafters in an attic? I see a lot of houses with no insulation on the inside of the roof.
- A typical composite shingle would get too hot if you insulated the roof directly underneath it, decreasing life of shingle. You want good air flow in attic, insulate above the ceilings only.
- Q: I already have fiberglass in the attic, but would like to add more.
- Blown in is easier, cheaper and can be a DIY project. Just make sure you don't block the soffitts that allow air to circulate.
- Q: we want to put a model railway up in the loft,and i like the idea of having white plastic cladding throughout up there,my hubby is insulating the roof tomorrow,but he prefers plasterboard,at least the cladding will be maintenance free,
- i think it might be able to pass code if you ever sell the house.i myself would use sheets of white wainscoting.also make sure the insulation if it has a paper backing ,paper faces the room.
- Q: I added a screened room to my mobile home. I also have vinyl windows. in the summer the sun beats down on the home almost all day Someone told me I could have insulation installed in the roof panels, and that i may even be able to do it myself. Right now it's impossible to enjoy my patio between 1-5pm because it so hot you can't breath. I'm in the Pasco, FL area - 34667Appreciate any help you can give
- Mobile home refoofing, I had it done, and they did it in one day. They came and installed 2inch foiled insulation right over the existing roof. Then they installed new roof panels..Unbeliveable how much cooler in the summer and warmer in the winter. It will pay for itself living up here in the Northeast..
- Q: I am in the process of having a new roof installed. What are my options in regards to improving its' insulating properties?
- I am going to convert my loft, so was researching this subject as well. I once saw on TV (I think on Renovation program) how they make insulation from sredded paper - this was a very inexpensive and very efficient way of doing it. Also they said that the best insulation is the one made from sheeps' wool. You can buy this from major DIY stores. Have a look at the links below
Send your message to us
Buy Roofing Insulation Boards - Aluminum Foil Coated Bubble Insulation Type 4
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10000 m²
- Supply Capability:
- 100000 m²/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords