• Aluminum Foil Coated Bubble Insulation Type 10 System 1
  • Aluminum Foil Coated Bubble Insulation Type 10 System 2
  • Aluminum Foil Coated Bubble Insulation Type 10 System 3
Aluminum Foil Coated Bubble Insulation Type 10

Aluminum Foil Coated Bubble Insulation Type 10

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10000 m²
Supply Capability:
100000 m²/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Bubble Insulation Benefits:

  • Reflects 96% of radiant heat

  • Non-toxic / Non-carcinogenic

  • Does not require protective clothing or respirators to install

  • Durable and lightweight

  • Does not compress, collapse or disintegrate

  • Vapor and radon retarder

  • Easy to cut and install

  • Permanent and maintenance-free

  • Does not provide a growth medium or nutritive value for fungus, insects, or rodents

  • Does not support the growth of mold or mildew

  • Not affected by moisture or humidity

  • Lowers heating and cooling costs year round

Bubble Foil Application:

 

  • Metal & Steel Buildings

  • Homes

  • Roof Underlayments

  • Cathedral Ceilings

  • Crawl Spaces

  • Hot Water Heaters

  • Basement Walls

  • Floors

  • Garage Doors

  • Concrete slabs

  • Driveway snow melts

  • Pole barns

  • Post frame buildings

  • Poultry barns

  • Animal kennels

  • Temperature sensitive storage areas

Air Bubble Foil Insulation Tech Data:

 

Material Structure:     AL/Bubble/AL

Bubble Size:D10mm*H 4mm(10*2.5/10*4/10*6/20*7/25*10)choose the bubble size

Bubble Weight:0.13kg/m2 ( can be customized )

Roll Width:1.2m (lenth can be customized)

PROPERTIES

TEST DATA

UNIT

Thickness

3.5-4

mm

Weight

250

g/m2

Emissivity

0.03-0.04

COEF

Thermal conductivity

0.034

w/m0

Apparent Density

85

kg/m3

Reflectivity

95-96

%

Water Vapour Transmission

0.013

g/m2kpa

Corrosion

doesn't generate

Tensile Strength(MD)

16.98

Mpa

Tensile Strength(TD)

16.5

Mpa

 

Q:I've found lots of building forums and general "building advice" columns that go over very high-level pros/cons to choosing roofing material and insulation options, but I want a site where I can see hard costs of ordering each of the materials so I don't have to call up a ton of contractors or dealers. Does such a comparison site exist? Everyone offers quotes, but that takes too much time to apply for quotes to every dealer.I'm specifically interested in knowing what green options I can afford (cotton batting vs. formaldehyde-free fiberglass, etc.).
i could propose the felt. I rather have heard the two execs and cons with regard to the extra moderen man made underlay, and that i'm no longer inspired. I consistently get rid of the previous roofing, positioned #30 felt down, positioned a 1x4 batten down, and positioned my steel on that. I additionally want the three' huge roofing
Q:I have a split house with an attic where I have insulation on attic floor, but the house seems to be cold still, Can I add insulation to the roof of the attic? If so, any options? Thank you.
No, you want the air to circulate from the soffit vent to the ridge vent or gable vents, whichever you may have. This will prevent mold and condensation.
Q:I need to call around and find a contractor to repair my roof. I thought it might be a good idea to at least have the name of this type of roofing correct so I don't sound like too much of a mark. Thank you in advance for your assistance.
Most typically, it's a sprayed polyurethane foam system. Simple repairs can be made with a sealant, unless you need a section replaced.
Q:do I have to blow insulation in the roof of my mobile home if I install foam insulation under a meatle roof?
Vapor barriers always go on the heated side of walls or ceilings. If you are going to add insulation to your attic and don't want to put in more blown in insulation ( which does have a better R-factor) then purchase unfaced fiberglass insulation to put on top of existing insulation. The thing you need to avoid is called double vapor barriers. Years ago when the first started playing with super insulated houses they would put a poly on the inside and outside of the walls. What happened is any moisture picked up in the walls going from summer to winter would get trapped in the walls and rot them out. No matter what only one vapor barrier on the heated side of the insulation!!! Then your house can breath and release moisture regardless how thick your walls or ceiling.
Q:roof was replaced eight years ago soon after there were leaks in the roof caused insulation toget wet then dry now the insulation is packed hard and has started to turn into power who would be responsible to replace the insulation.
Sorry; I don't know of any roofer that would take responsabilty after eight years. Unless your insurance might be an option. Check with them and decide if your deductable is more than the repair if you would be better off doing it yourself. I would also be concerned about underlying materials, sheet rock, lumber, MOLD. You need someone to check thoroughly for mold being as it has been so long. GOod luck; Flip;
Q:My new room is an addition to a mobile home, and has a single-layer metal roof. I have 3 "main" concerns. What are the cheapest and/or most effective ways of eliminating them?1. No heat insulation- cold air sinks from the roof to my room, and my warm air rises to the roof and cools.2. Condensation forms on the inside and drips occasionally. My computer, bike, and downhill boards are in here!3. It seems like bugs could easily get into my room, but that's just a suspicion.
You really need a correct "building paper" under the iron. It is aluminum with a tar sandwiched between...You can also use plastic sheeting as a vapor barrier..
Q:I am building a porch roof over an existing patio. The rafters are fabricated I-beams. I plan on putting aluminum soffit under the I-beams. On top of the roof I would like to put down a metal roof. I already put down 3/4" OSB and a rain/ice barrier. Do I need insulation and/or ventilation on top of the rain and ice barrier, or can I get away without it?
Its a outside patio, are you going to enclose it for living space? If not don't bother to insulate and for ventilation there is soffit that comes with vent holes in it. Add; no it will not cause a moisture problem, i had a patio with a open bottom metal roof and had no problems and i live in Florida.
Q:I have a vented metal roof. WV winters
Check into heat tape tied to pipe, with insulation wrapped around that. turns on when freezing temperatures. insulation by itself, will not stop it from freezing if left for long periods without water moving through it. .
Q:hi me and my friends made a lounge out of my old tin roof shed we have a tv speakers and a few other electrical goods... since winters on its way we were wondering whats the best and cheapest way to insulate the place note that its a tin rof but has wood under it where the old indulation used to be the place is pretty chilly and sometime damp plz help we dont wanna be freezing our asses off in there thanks :)
What is he using glue on? Buy rolled fiberglass insulation, install it between the rafters and wall studs...paper side in. You can cover the walls and ceiling with drywall, OSB, plywood if you wish. You do realize that insulating your shed isn't going to make it much/any cooler don't you? You will need an air conditioner for that, but the insulation will help keep the AC in.
Q:the roof of my mouth hurts bad.i worked all day with sawdust and insulation yesterday.is this the problem.?
The okorder , and see if I could find out anything there, if not I'd see my doctor. Insulation can get into your lungs and nasal passages and do a great deal of damage. That's why you should always wear a mask when woking with it. I would'nt worry too much about the sawdust.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords