Place of Origin: | Zhejiang, China (Mainland) | Brand Name: | cnbm | Model Number: | VV YJV VV22 YJV22 VV32 YJV32 VV62 YJV62 VV72 YJV72 YJLW02 YJLW03 KVV |
Insulation Material: | PVC or XLPE | Type: | Low,Medium and High Voltage | Application: | s electric power distribution networks or industrial installations |
Conductor Material: | Copper or Aluminium | Jacket: | PVC or PE | Filler: | Non-hygroscopic Polypropylene(PP) |
Binder Tape: | Non-woven fabric | Metallic Armour 1: | Galvanized Stainless Steel Tape Armour(STA) | Metallic Armour 2: | Galvanized Stainless Steel Wire Armour(SWA) |
Metallic Armour 3: | Non-magnetic Steel Tape Armour(only for single core) | Metallic Armour 4: | Aluminium Wire |
Packaging & Delivery
Packaging Details: | wooden drum; iron-wooden drum or steel drum |
Delivery Detail: | Depending on the quantity |
Specifications
2015 new product electric power cable
1 Conductor:Copper or Aluminium
2 Insulation:PVC or XLPE
3 Voltage:Low/Medium/High Vol
2015 new product electric power cable
Technical Parameters of our Power Cable
1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890
2). Detailed description or construction:
* Conductor: compacted or uncompacted copper or aluminium
* Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
* Filler: Polypropylene filament with lapped binding tape
* Binder: Binding tape
* Inner sheath: Polyvinyl chloride (PVC)
* Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)
*Sheath: Polyvinyl chloride (PVC)
3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:
U0/U(Um) =0.6/1(1.2)-3.6/6(7.2)-6/10(12)-6.35/11(12)-8.7/15(17.5)-12/20(24)-12.7/22(24)-18/30(36)-19/33(36)-26/35(40.5)KV
4). Voltage:
0.6/1kV, 1.8/3kV, 3.6/6kV, 6/10kV,6.35/11kV, 8.7/15kV, 12/20kV,12.7/22kV, 18/30kV,19/33kV,26/35kV
In the voltage designation of cables U0/U(Um):
* U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
* U is the rated power frequency voltage between conductors for which the cable is designed;
* Um is the maximum value of the "highest system voltage" for which the equipment maybe used.
5). Application:
For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.
6). Marking: According to the customers' requirements
FAQ
· Can we make an OEM order?
o We can offer or supply goods as customers' requirements.
· How can I get some samples? Free or not?
o We can send some normal samples, absolutely free.
· How does your factory do regarding quality control?
o "Quality is priority." We always attach great importance to quality controlling from the very beginning to the very end. Our factory has gained ISO9001 , SGS authentication, CE for Europe, etc.
- Q: Where can I buy a power cable with converter for a Dell Inspiron 2200?
- my okorder /
- Q: If the question, please ask how the power cable should be set when the set of quotas (08 installation quota)? More
- SC pipe welding fluid with welded steel pipe, the general thread connection, or casing welding connection. TC pipe is a thin-walled steel pipe, referred to as wire tube, you can thread connection, tight connection, buckle type connection, not casing welding connection.
- Q: What are the causes of the power cable fire accident? How to prevent
- with a white cable to facilitate the distinction between the cable
- Q: I have recently decided to scrap my capacitor and need and extra two feet of power cable in order for it to reach the amp....is it possible to splice and join two power cables together or is it a better idea to rewire with a longer cord?
- The only way to properly splice the cable is to solder the cable to another piece of cable the same size. The best insulator is brush on tape , just make sure whatever you choose to use, it is sufficiently wrapped. There should minimal power loss if care is taken to make the connection well. However, the best way would be to run a new cable. But considering the trouble this may pose, a quality spice may be the best choice.
- Q: The other day I found an imac g5 17computer in my alley. It probably doesn't work but I was just curious about what cables/accessories I need for it. All that was out there was the actual monitor/desktop. There were no cables with it. (By the way if you can't tell I am not experienced with computers)Thanks any info is appreciated!
- Power cable, USB keyboard, USB mouse. That's it. Find a power cable (any old computer power cable will work) and see if it even powers on and does anything first. Crack it open. Set it on its face, then undo the three screws across the bottom. They do NOT come out. They only loosen up until you can't turn them anymore. The back pops off. Look for any swollen or leaking capacitors. If you find any, then it's junk. If you don't, then see if there's any RAM in it. If not, toss some PC3200 DDR RAM in there and see if you get anything.
- Q: at the end of power cable are 2 wires
- I don't know what you mean by 302cm power cable. When it has 2 wires, one if usually the hot (power) and one is the ground (earth.) I don't know much else that'll help you, sorry.
- Q: I'm extending one of my PSU power cables because is to short. the line got 2 black/1 yellow and 1 red (molex) I know the colors have to be matched but if at the other end I end up mixing the 2 black lines, will there be a problem?ps: I already sleeved the cable for that matter I can't see the 2 black cables inside and i forgot to mark them. :)
- Mixing the Two Black Wires doesn't matter becuase the Black Wire = 0V it is common wire used with red and yellow. The Red Wire = 12V and the Yellow Wire = 5V so don't mix the Yellow and Red Wire and be sure to connect the Yellow and Red Wires to the Correct Place in the Connector because if wrong connection made with yellow instead of red it will damage your hardware.
- Q: if I buy a new 4 pronged power cable how should i install in the dryer,what should i do with the extra 4th wire of the cable,pls help Thanks
- Remove the jumper from the neutral lug, (the center lug), to the appliance chassis. Attach the ground wire to the appliance chassis. The 3 lug terminal hooks up Hot-Neutral-Hot. Make DAMNED SURE the appliance chassis is grounded.
- Q: I am trying to modify my my xbox 360(put it into a pc tower that I have) but the DVD power and sata cables won't even come close to reaching. As well as the cables needed to move the rest of my peripherals. Please point me in the right direction or to a website that has these cables for sale. I need 10 inchers if possible. Thanks in advance!!!
- Open QuestionShow me another ? What is a good entension cable for the xbox 360 sata and power cables? I am trying to modify my my xbox 360(put it into a pc tower that I have) but the DVD power and sata cables won't even come close to reaching. As well as the cables needed to move the rest of my peripherals. Please point me in the right direction or to a website that has these cables for sale. I need 10 inchers if possible. Thanks in advance!!!
- Q: I have a usb hub that is externally powered that stays on 24/7 even when i shut my computer off. It is buried behind by desk so removing the usb power supply manually each time is what im trying to avoid. Is there anyway i can put a switch in the power cable going to it?
- Before you attempt this, make sure you have the following items: -Wire strippers -Electrical tape -Two terminal switch -Scissors IMPORTANT! make sure that the cable is unplugged from the computer and the hub before you do this! 1st, cut the cord halfway with the scissors. Next, remove the outer wire insulation from the two new ends you just cut with the wire strippers. Now strip the small colored wires that are now exposed. Then connect the red wire from one half of the cord to a terminal on the switch. Do the same with the other red wire from the other half of the cord and connect it to the other terminal on the switch. Strip the other small wires and connect them back to their appropriate colored wire. Finally, wrap each wire individually with electrical tape, then wrap the entire gap in the cord with it. Now plug the cord in and try it out!
Send your message to us
2015 China Degree Teflon Cable Shield Wire
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 50000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches