Place of Origin:

Zhejiang, China (Mainland)

Brand Name:

cnbm

Model Number:

VV YJV VV22 YJV22 VV32 YJV32 VV62 YJV62 VV72 YJV72 YJLW02 YJLW03 KVV

Insulation Material:

PVC or XLPE

Type:

Low,Medium and High Voltage

Application:

s electric power distribution networks or industrial installations

Conductor Material:

Copper or Aluminium

Jacket:

PVC or PE

Filler:

Non-hygroscopic Polypropylene(PP)

Binder Tape:

Non-woven fabric

Metallic Armour 1:

Galvanized Stainless Steel Tape Armour(STA)

Metallic Armour 2:

Galvanized Stainless Steel Wire Armour(SWA)

Metallic Armour 3:

Non-magnetic Steel Tape Armour(only for single core)

Metallic Armour 4:

Aluminium Wire



Packaging & Delivery

Packaging Details:wooden drum; iron-wooden drum or steel drum
Delivery Detail:Depending on the quantity

Specifications

2015 new product electric power cable 
1 Conductor:Copper or Aluminium 
2 Insulation:PVC or XLPE 
3 Voltage:Low/Medium/High Vol

2015 new product electric power  cable  

Technical Parameters of our Power Cable 

1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890

2). Detailed description or construction:

    * Conductor: compacted or uncompacted copper or aluminium

    * Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)

    * Filler: Polypropylene filament with lapped binding tape

    * Binder: Binding tape

    * Inner sheath: Polyvinyl chloride (PVC)

    * Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)

    *Sheath: Polyvinyl chloride (PVC)

3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:

    U0/U(Um) =0.6/1(1.2)-3.6/6(7.2)-6/10(12)-6.35/11(12)-8.7/15(17.5)-12/20(24)-12.7/22(24)-18/30(36)-19/33(36)-26/35(40.5)KV

4). Voltage:

     0.6/1kV, 1.8/3kV, 3.6/6kV, 6/10kV,6.35/11kV, 8.7/15kV, 12/20kV,12.7/22kV, 18/30kV,19/33kV,26/35kV

    In the voltage designation of cables U0/U(Um):

        * U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;

        * U is the rated power frequency voltage between conductors for which the cable is designed;

        * Um is the maximum value of the "highest system voltage" for which the equipment maybe used.

5). Application:

     For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.

6). Marking: According to the customers' requirements

2015 China  Degree Teflon Cable Shield Wire

2015 China  Degree Teflon Cable Shield Wire

2015 China  Degree Teflon Cable Shield Wire

2015 China  Degree Teflon Cable Shield Wire

2015 China  Degree Teflon Cable Shield Wire

2015 China  Degree Teflon Cable Shield Wire

2015 China  Degree Teflon Cable Shield Wire

FAQ

·         Can we make an OEM order?

o    We can offer or supply goods as customers' requirements.

·         How can I get some samples? Free or not?

o    We can send some normal samples, absolutely free.

·         How does your factory do regarding quality control?

o    "Quality is priority." We always attach great importance to quality controlling from the very beginning to the very end. Our factory has gained ISO9001 , SGS authentication, CE for Europe, etc.


Q: i soldered in one of those ribbon cables on to my hp's laptop power button cause the old ribbon was failing. anyways i am having some issues with this new cable1 the laptop will power on by itself if i insert the ribbon into the motherboard connector2 the only way to power off the laptop is to remove the cable from the mother board connector and that means opening up the whole laptop3 like i said it will power on by itself so that means that i cant turn it on/off with the power buttonevery thing is soldered correctly i dont understand also i am not sure but does the cable have to be like the old one cause the new one i soldered in looks the same? could it be that it needs that one particular cable replaced again? please help me i am sad
Time to hang up our computer repair skills and take it to a shop...
Q: So my vehicle's amp recently stopped working. It worked great after I installed it about a year before, so after testing for shorts, burnt out fuses, etc, I decided that the amp had died on me. After getting a new one-and it not working either-I checked the voltage at the end of the power cable where it hooks onto the amp. I get a 12v reading when the ignition is off, but only a 4v reading when it is in the run or aux. position. The in line fuse is good, as well as the battery (just had it checked). Any ideas as to why this is happening? As of this posting, I have NOT tried running a new power cable yet, but that is the next step if nobody has an answer. Thanks.
I had a similar problem a few years ago and simply couldn't make sense of it. I traced the power wire back testing it every couple feet and eventually got to the AGU fuse holder. I had ~14v on the battery side and very little voltage on the amp side. It LOOKED fine, and the fuse was fine, but something weird going on in the fuse holder itself simply wasn't making a good connection. I replaced it and was back up and running. I'm not going to say that's definitely your problem, but it's worth a check,
Q: VV3 * 120 + 2 * 70 cable what does it mean
Trough is not conducive to heat, tray heat slightly better There is a cooling hole in the bottom of the tray tray Due to open the cooling holes, tray-type bridge plate thickness to thick points ★ problem belongs to the subject: professional information technology engineering water conservancy project the above content is based on the actual work of the students encountered problems, for reference, if any questions please communicate in time, correction
Q: What type of plastic is a power cable made of? Thanks.?
Power cable isn't made of plastic, it is copper or aluminum covered with PE, PVC, or PTFE plastic.
Q: Im running a dedicated power cable from battery to trunk for 2 amps and i just want to know if drilling a hole through the firewall is the only way to do it? What happens in 15 years when the hole gets rusted and coroded from the moisture even with a gromet?
2 amps is a pretty small current so it doesn't need a big cable - there are other cables passing through for the back lights, find out where they run and see if you can just ease another one through the gap,it might work with a little lubrication. Just don't try to poke anything sharp through the hole. There are special fish wires that electricians use to get cables through holes conduits, you could try one of those or at least see how they are shaped so you can use something similar - you'll only need a short fishwire you probably have to buy a 5m length if you want the real thing. Good luck.
Q: Hi,I bought a new 500GB HDD today, with a SATA cable (data) but I don't know what kind of power cable I need?I looked around and saw Sata to Molex and all kinds of things, I've never had to hook up a second hard drive before and the terms are confusing me. Could anyone tell me what kind of cable I'll need and where I'm supposed to hook them up to?Thanks!
Your PSU, should have all of the needed connectors.
Q: How can i fix it and how much would it cost?
its possible (unless you're sure) that its not the socket. It could be the surge adapter(the plug itself). possible it can be the outlet itself, have you checked a different outlet? Anyway, fortunately, that's not too big of a problem, especially for a laptop. To get it fixed, if its still under warranty, you have to call the manufacturer and ask for technical support. They will most likely send you a box to put the computer in, have you send it to them(prepaid), and they will send it back repaired, IF ITS UNDER WARRENTY. If its not under warranty, you will have to go to a computer technician. usually a place like Best Buy has fast and cheap computer repairs, or you may find a local computer repair shop that suits your needs better. Or you can even send it back to the manufacturer to fix it, be warned however, they usually overcharge on expired warranty repairs. As far as the cost, it can range from fifty to a couple hundred dollars, depending on the problem. Hope i helped
Q: I am getting a new 160 amp high output alternator for my 2005 Mazda 3 2.3L. I am running a 1000w amp with two subs. I have the stock alternator in it right now. There are two power cable kits available for me to get. One that has 4 gauge wire with a 100 amp fuse and the other, 1 gauge with 150 amp fuse. Which kit should I get? Can I just add 4 gauge wire along with my stock wire instead of the 1 gauge kit? What are the fuses for and which one would work better? I know nothing about this. Thanks.
I would go with the 1 ga wire. The fuse keeps the wire from setting your car on fire. The size of the alternator does not matter. The battery should supply 700 amps or so.
Q: cable or do they need certain ones, I ask because this PSU: has no power cable with it so will i have to get a certain power cable for that wattage or are they all the same???please answer, 10 points for first answer
all psu's ( even the ebuyer one) will use the same 3 pin cable.....just like the one most monitors use :) ...but uf u dont have any of these 3 pin power cables ur gnna have to buy one here is an image of one
Q: I have 8x220ah deep cycle car battery's at 12v and i wanted to run an 5kw 12v power inverter but i would need cable which is 400amp 12x4004800 so could i use two cable connected to the battery's and split the power into 2 cable or would this not work if so whythe inverter would be using 400amps from the battery and it would be supplying 20amps at 240voltsis my working out correct
In this case, you should have put the batteries in series to get 48 or 96 volts, that makes the cabling easier. Too late now. Yes, at 5kW, that is 5000/12 420 amps I don't know what size wire you are using, and what the distance is, so I can't help further without that information. For example, if you are running 10 feet of cable (20 total) and you want to lose only 5% of the voltage, which is 0.6 volts, then the resistance of the wire needs to be less than 0.6/420 1.4 mΩ. That is, over 20 feet, 71 mΩ per 1000 feet, which is 000 AWG wire. Mush more than 10 feet, and you need to use MCM wire. .

Send your message to us