XD series vacuum pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
XD series vacuum pumps can work for long term in the well-ventilated room with ambient temperature of 5-30 ℃ and with humidity ≤80%.
In addition to the above applications, the XD series vacuum pumps can be available other applications, such as:
1. To increase the amount of the pumping gas and to improve the vacuum degree, please combine with Roots pumps to form a unit for this.
2. If pumping moist air or condensable gas, the condenser can be installed before the vacuum pump and the gas ballast valve is installed on the vacuum pump.
3. If pumping the gases containing dust particles, the dust filters can be installed in front of the vacuum pump.
4. If pumping the corrosive gases, the corrosion-proof gas filter can be installed in front of the vacuum pump.
List of performance
Parameters Model | XD-020 | XD-040 | XD-063 | XD-080 | XD-100 | XD-160 | XD-202 | XD-250 | XD-302 |
Pumping rate (m³/h) | 20 | 40 | 63 | 80 | 100 | 160 | 200 | 250 | 300 |
Pressure limit (mbar) | 0.1~0.5 | 0.1~0.5 | 0.1~0.5 | 0.1~0.5 | 0.1~0.5 | 0.1 | 0.1 | 0.1 | 0.1 |
Motor power (kw) | 0.75 | 1.5 | 2.2 | 2.2 | 3 | 4 | 4.5 | 5.5 | 7.5 |
Motor speed (r/min) | 2880 | 1440 | 1440 | 1440 | 1440 | 1440 | 1440 | 1440 | 1440 |
Noise (db) | ≤62 | ≤65 | ≤65 | ≤65 | ≤ 67 | ≤ 70 | ≤ 72 | ≤ 73 | ≤ 75 |
Allowable steam pressure (mbar) | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 |
Pumping water steam (kg/h) | 0.3 | 0.3 | 1 | 1 | 1.6 | 2.5 | 4 | 4.5 | 5 |
Working temperature (℃) | 82 | 80 | 80 | 80 | 84 | 95 | 95 | 81 | 83 |
Oil volume (L) | 0.5 | 1 | 2 | 2 | 2 | 5 | 5 | 7 | 7 |
Weight (kg) | 18 | 45 | 55 | 60 | 70 | 150 | 150 | 195 | 211 |
Air intake thread | Rp3/4’’ | Rp1/4’’ | Rp1/4’’ | Rp1/4’’ | Rp1/4’’ | Rp2’’ | Rp2’’ | Rp2’’ | Rp2’’ |
Overall dimensions | 650*300*280 | 650*300*280 | 650*430*295 | 650*430*295 | 720*430*295 | 850*505*440 | 850*505*440 | 980*560*440 | 1010*560*440 |
- Q: What are the characteristics of a pipe shield pump?
- Four, high melting point in the pump hydraulic side and the motor side with a jacket, the jacket can be steam or a certain temperature of liquid to prevent high melting liquid crystallization. The outer circulation pipe of the pump should also be insulated (heating) jacket. Five, high pressure shielding pump shell is a high pressure container, so that the pump can withstand high system pressure. In order to support the shield under internal high pressure, the stator coil itself can be used to bear the pressure. Can also be made in high temperature and high pressure under the operation of the canned pump. Six, since the suction port of the pump impeller center is much higher than that in stopping the pump, when inhaled NO liquid in the tube, the impeller and the increase of the pump chamber is filled with liquid, and then start without irrigation, the pump can work. Self-priming pumps are especially suited for extracting liquids from underground containers. In addition, according to different methods can be divided into liquid type, mud type, high pressure pipeline type, as well as for ships, nuclear power plants and absorption refrigeration devices for various types of canned pumps. Can also be divided into vertical, horizontal, online and single-stage, multi-level and other different types.
- Q: What are the functions of a disposable infusion pump?
- When the transfusion is too slow, the dosage may not be enough, or the infusion time is prolonged unnecessarily, the treatment is affected, and unnecessary burden is added to the patient and the nursing work. In routine clinical infusion, the infusion of hanging bottle is generally used, and the speed of infusion is controlled by the use of a manual clamp. The speed of infusion is not easy to be controlled accurately, and the workload is great.Treatment of cancer patients with chemotherapy and critically ill patients need to make drug infusion rates constant, by adjusting the input speed and duration of chemotherapy drugs is continuously injected into the uniform, not only to achieve the best effect of chemotherapy, and to minimize the side effects of chemotherapy drugs.People suffering from diabetes need to inject a certain amount of insulin at a certain speed. The previous approach is basically a large dose of insulin injection, which not only caused a huge waste, and the effect of time is relatively short, so for a conveying device of flow and velocity control, to carry a small amount of drugs and precisely control the conveying speed and flow.Some special drug delivery to the elderly, children and physical weak, such as drugs, antihypertensive drugs, sodium nitroprusside (three TPN codehydrogenase) when the infusion rate and dosage should seriously control accurately, otherwise it will have serious consequences.
- Q: Water pump outlet valve sequence
- In order to prevent the generation of water hammer when the pump stops the damage to the rubber head, should be immediately set rubber head pump outlet, the gate valve and the check valve is not a very convincing reason to decide the order of habits in our hospital order rubber head, check valve, gate valve1. Check valve located in front of the pump, I do not know what the significance is too great to think of.2. The actual installation sequence shall be: soft fittings, check valves, gate valves. The pressure gauge is best installed on the water outlet of the pump, but it must be in front of the check valve.Reason: 1) the soft joint is used to reduce vibration. The connection between the pump and the piping system, of course.2) normal work, the gate valve is not operating, and the check valve is frequent action, so the probability of maintenance is larger, when the maintenance of the pump closed, the water outlet valve can be maintained without affecting the normal operation of the system.3) the pressure gauge is installed in the check valve, which can prevent the impact and damage of water hammer on the pressure gauge.
- Q: If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
- Submersible pump even if it really leakage, it will not cause the fish electric shock. The so-called leakage is the submersible pump wire or shell broken, live parts and water contact, the most extreme test is a fire line directly into the fish tank
- Q: Does the reservoir water heater press the booster pump (high marks)?
- In addition, the water storage electric water heater has a safety valve is O.7MPa, before buying a booster pump, you can check the water inlet valve spring weakness, see the effect of water, barely even, then use it, do not buy.
- Q: Water pump does not produce water, what are the reasons?
- The reason why centrifugal pump does not produce water:1. pump inlet or sink, water tank water shortage.2. water pump pipe blocked or valve not open.
- Q: Please give me professionals to calculate, the cylinder bore is 100 and the rate of 20m/s, the leakage can be ignored, but to the large flow pump!
- 1. rpmOperating speed is the actual rotation speed of a pump (or motor) at work.Rated speed is the maximum speed that can operate normally for a long time under rated pressure. If the pump exceeds the rated speed, the work will cause insufficient oil absorption, vibration and noise, the parts will suffer cavitation damage, life expectancy.Minimum steady speed is the minimum speed allowed for normal motor operation. At this speed, the motor does not appear crawling phenomenon.
- Q: I want to know the concrete under 60 type pump performance, it is mainly the pump long spiral bored piles, such as the diameter of the pump, transportation distance, pumping height and so on, thank you!
- HBT60.13.90S performance parametersParameter name unit HBT60.13.90SMaximum theoretical concrete conveying capacity m3/h 69/43Maximum pump outlet pressure Mpa 13/7
- Q: Is the flow meter in front of the pump or after the pump?
- Agree upstairs. Pump should be straight before the paragraph, 15 times the nominal length of the caliber.
- Q: How to calculate the motor power of metering pump?
- The motor power of the metering pump is divided into two parts1. mechanical power, this part of the power metering pump design part will be some data, mainly to control the mechanical structure of the metering pump required power
Send your message to us
XD series vacuum pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords