• Water Ring Vacuum Pump System 1
Water Ring Vacuum Pump

Water Ring Vacuum Pump

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

1. high vacuum, low power,high pump speed
2. widely used in mining industry
3. ultimate pressure: 33mbar

Instructio

2BV series liquid ring type vacuum pump and compressor as the new generation of energy saving products, its outstanding performance and advantages will replace SK, 2SK series water ring vacuum pump, W, WY, WL series reciprocating vacuum pump.

Advantage

2BV series pump for air and water vapour pressure to breathe, 33mbar absolute pressure (97%), vacuum pump suction pressure when in 80mbar below the condition, long-term work connected with protecting tube cavitation erosion of pump injector, i.e., protecting atmosphere, inspiratory pressure can reach 10mbar, injector pump can be directly mounted in a compressor, the pressure, to 0.26 MPa (maximum absolute pressure).

2BV series water ring vacuum pumps as a new generation energy-saving products, and the excellent performance and numerous advantages will be fully replace with same properties of SK, 2SK series water ring vacuum pumps and W, WY, WL series reciprocating vacuum pump.

Vacuum pump accessories: impeller,disc, the pump cover, pump body materials can be chosen as following:

SUS304 (0Cr18Ni9)
SUS316 (0Cr17Ni12Mo2)
SUS316L (00Cr17Ni14Mo2)

Pump shaft materials:2Cr13, SUS304 and SUS316L

Mechanical seal uses imported products, Seals can use viton or PTFE.

2BV2 - Ex, 2BV6 series water ring type vacuum pump/compressor is mainly used for surking explosive gas, and various inflammable and explosive of working environment, its performance parameters are as the same as 2BV2, 2BV5 series

               

Model

Max. capacity

m3/h

Limiting vacuum
mbar(MPa)

Motor power
KW

Speed
r.p.m

Flowrate
L/min

Noise
dB(A)

Weight
kg

2BV-B060

27




33mbar
(-0.097MPa)

0.81

2840

2.5

62

37

2BV2-B061

52

1.45

2840

2.5

65

41

2BV2-B070

80

2.35

2860

3

66

66

2BV2-B071

110

3.85

2880

4.7

72

85

2BV-E110

165

4

1440

7.2

63

120

2BV-E111

230

5.5

1440

8.8

68

150

2BV-E121

280

7.5

1440

11

69

210

2BV-E131

400

11

1460

16

73

280

2BV-E161

500

15

970

22

74

390

2BV-F110

165

4

1440

67

63

150

2BV-F111

230

5.5

1440

10

68

200

2BV-F121

280

7.5

1440

12

69

230

2BV-F131

400

11

1460

17

73

315

2BV-F161

500

15

970

23

74

426

Picture

       

               

     

Q: What is the dry running protector of screw pump? What's the principle and function? Thank you
Principles are generally temperature sensing, such as: when the screw pump by air, the stator and rotor will be heated due to friction,
Q: What is the lift off the dead center point? This is a straight mark about the water pump. What is the function and the relationship between the design head and the pump head? ThanksWhat exactly is the dead point lift? What's the function of this indicator?
The dead point head is the measured head after the outlet valve is closed. Mainly on the lower reaches of the pump equipment, such as your dead center, the lift is 300 meters, that is, 3MPa
Q: Operating procedures for measuring pumps
Pressurization(1) for the discharge pressure below 2.0MPa, then the pump stroke length should gradually increase, each increase of 20%, to maintain 15 minutes.(2) for the discharge pressure greater than 2.0MPa, you need a special pressure, to ensure that the pump discharge pressure gradually increased, each time for the final row pressure of 20%.(3) when the pressure is not increased, the stroke of the pump is gradually increased by 20% strokes per time.Note (1) when pressure is applied, the pressure gauge should be observed at the side of the loading side (slow motion)(2) check ammeter, forbid overload
Q: Please give me professionals to calculate, the cylinder bore is 100 and the rate of 20m/s, the leakage can be ignored, but to the large flow pump!
Select the hydraulic pump from the following considerations:1. hydraulic pump pressureHydraulic pump operating pressure is the pump (or motor) in actual work output (or input) oil pressure, determined by the external load.Rated pressure refers to the maximum pressure under continuous running in accordance with the test standards under normal working conditions. The size of the pump is limited by the service life, and the service life of the pump (or motor) will be shorter than the design life if it exceeds the rated pressure. When the work pressure is greater than the rated pressure, it is called overload.
Q: What is the function of the heating pump system for the water pump design?
As the feed water temperature is higher, before starting, if not enough to warm the pump, the pump body temperature is uneven, there is a hot, cool phenomenon. The upper part is inflated and the lower part is inflated"
Q: Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
(three) infusion limited number of pills produced after the dose of obstruction by infusion pump and specification of the matching test, will reach acceptable when the storage pressure of the pressure to determine the alarm blocking. Thus, some have restrictions on the infusion tube blocked after the maximum dose pill may have blocked the trigger before the alarm.
Q: Harm of air pump and pump
If the liquid is not full, this situation is generally the suction pipe or pump shell leakage, then easy to cause cavitationHit the pump for centrifugal pumps, centrifugal pump is recommended to start closed, the discharge valve closed, starting is in the state of pump
Q: If the calculation of the required pump flow is 45, lift 110, and the actual pump flow 100, head 125, what will happen in operation? Can I use it properly?
Centrifugal pumps are too big to measure.There is a reason why the centrifugal pump does not measure up:The pump inlet pipe blockage, leakage.The pump inlet pressure is too low.
Q: What is a vacuum pump for?
You are not confused by different names. It is mainly used in folding machines, paper cutting machines and water treatment aeration
Q: What is the series of pumps? What is the difference between a unipolar and a multilevel? What is the meaning of each "first class"?
A single-stage pump is a pump with only one impeller. 2, a multistage pump is a pump with two or more impellers. The multistage pump can increase the pressure and lift the head higher. Level 1 means a booster impeller.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords