• W Vortex Water Pump System 1
W Vortex Water Pump

W Vortex Water Pump

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

W type vortex pump
1. Competitive price.
2. Low noise and steady.
3. High efficiency
4. Energy saving

W type vortex pump


1. It is widely used in chemical engineering, pharmacy,food,cigarette, and institute etc.

2. We can supply different good quality single-stage vortex pump.

3. Vortex impeller shaft can move freely along the axis to ensure that the impeller and pump body, pump cover gap between both sides of the same axis, allowing paper to adjust pad clearance. Seal whirlpool pump and fill the form of a single mechanical seal face two whirlpool pump and motor together in a common base.


Model

flow (m³/h)
head
(m)

Power (kw)
pipe size

Voltage
(v)

Velocity(r/min)
(mm)
寸/lnch
25W2.5-12
2.5
120
3
25
1
380
3000
40W-6.5-130(Valve)
6.5
130
4
40
1.5
380
3000
40W-5-160(Valve    )
5
160
7.5
40
1.5
380
3000




Q: What's the pump? Where can I use it?
A pump is a machine that transports liquids or pumps liquids. Pumps are ubiquitous in life. They can be used to transport liquids such as water, oil, acid and alkali, emulsions, suspensions and liquid metals, as well as liquids, gas mixtures, and liquids containing suspended solids.
Q: Water pump can not be pumped out, how to maintain water?
Severe vibration of water pumpIt is possible that the rotor is unbalanced, or the coupling is not good, the bearing is worn and bent, and some parts may be loosened and broken. They can be adjusted, repaired, strengthened or replaced separately.
Q: Double floor sewage pump circuit diagram of a small problem
Question 3 when the water level is low, when the 1KA is connected, the pump will run depending on where your SS selector switch is located. Its left and right position, running pump and standby pump definition is different, left position is 1#, running 2# standby, right position is 2# running, 1# standby. Only inIn case the high level switch 2KA is connected, the standby pump may work at the same time.
Q: What is the working pressure of the hydraulic pump in the hydraulic transmission system?
The choice of pressure depends on the size of the load and the type of equipment. Consideration shall also be given to the assembly space, the economic conditions and the availability of components for the actuators.In the case of a certain load, low working pressure, is bound to increase the structure size of the actuator on some devices, the size must be limited, from the perspective of material consumption is not the economy; on the other hand, the pressure to choose too large, the pump, cylinder, valve and other components of the material, sealing and manufacturing accuracy requirements very high, must raise the cost of equipment.
Q: Is the centrifugal pump large or small?
When the liquid is lowered at a certain temperature to the vapor pressure at this temperature, the liquid bubbles. The phenomenon of producing bubbles is called cavitation. When the bubbles are flowing to the high pressure, the volume of the bubbles is reduced so that they are destroyed. This due to the pressure of rising bubbles disappear in the liquid in the phenomenon called cavitation bubble collapse. The local pump is in operation if the over-current part (usually the impeller blade inlet somewhere later) for some reason, the absolute pressure of pumping the liquid was reduced to liquid vapor pressure temperature, liquid vaporization began there, produce a lot of steam bubble formation, when the liquid contains a lot of bubbles by forward high pressure impeller Zone, high pressure liquid around the bubbles in the bubble decreases drastically and rupture. Condensation in the bubble burst and the liquid particle at high speed to fill a hole in this moment has a very strong effect of water hammer and the impact of high frequency against the metal surface, the impact stress of hundreds to thousands of atmospheric pressure, impact frequency can be up to tens of thousands of times per second, serious breakdown when the wall thickness will be. The process of cavitation in a pump is caused by the bursting of bubbles and bubbles in the water pump and the destruction of the over-current components. Water pump cavitation, in addition to the over-current components will have a destructive effect, but also produce noise and vibration, and lead to the performance of the pump down, seriously when the pump will be interrupted liquid, can not work properly.
Q: What are the main performance parameters of hydraulic pumps?
Main performance parameters of hydraulic pump:1. Hydraulic pump pressureHydraulic pump operating pressure is the pump (or motor) in actual work output (or input) oil pressure, determined by the external load.Rated pressure refers to the maximum pressure under continuous running in accordance with the test standards under normal working conditions. The size of the pump is limited by the service life, and the service life of the pump (or motor) will be shorter than the design life if it exceeds the rated pressure. When the work pressure is greater than the rated pressure, it is called overload.
Q: Why is the flow of the pump too small will occur cavitation phenomenon?
Why is it easy to produce cavitation when the inlet flow of pump is lowered?This is because the main performance parameters such as the head, power and efficiency of the centrifugal pump are not fixed, but vary with the flow rate. The curve drawn on a coordinate paper is called the performance curve or characteristic curve of the centrifugal pump. What happens when the flow rate decreases? The disadvantage of throttling adjustment is that the pump flow is small, and the impeller is easy to cause cavitation
Q: If the calculation of the required pump flow is 45, lift 110, and the actual pump flow 100, head 125, what will happen in operation? Can I use it properly?
Centrifugal pumps are too big to measure.There is a reason why the centrifugal pump does not measure up:The pump inlet pipe blockage, leakage.The pump inlet pressure is too low.
Q: What is the difference between the ground pump and the pump in the commercial concrete?
Day pump: the pump and pipe will be placed in a position on the site, the pipe in the air like the crane arm
Q: Why adjust the centrifugal pump outlet valve can adjust the flow? What are the advantages and disadvantages of this method? Is there any other way to regulate the flow of the pump?
This method can be used to regulate flow. The advantage is that it is simple and easy to use and the disadvantage is that the throttle consumes energy

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords