W type vortex pump
1. Competitive price.
2. Low noise and steady.
3. High efficiency
4. Energy saving

W type vortex pump


1. It is widely used in chemical engineering, pharmacy,food,cigarette, and institute etc.

2. We can supply different good quality single-stage vortex pump.

3. Vortex impeller shaft can move freely along the axis to ensure that the impeller and pump body, pump cover gap between both sides of the same axis, allowing paper to adjust pad clearance. Seal whirlpool pump and fill the form of a single mechanical seal face two whirlpool pump and motor together in a common base.


Model

flow (m³/h)
head
(m)

Power (kw)
pipe size

Voltage
(v)

Velocity(r/min)
(mm)
寸/lnch
25W2.5-12
2.5
120
3
25
1
380
3000
40W-6.5-130(Valve)
6.5
130
4
40
1.5
380
3000
40W-5-160(Valve    )
5
160
7.5
40
1.5
380
3000




Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
Modify the part: (the design of regional common fire pump should be in accordance with the requirements of the original design, building design) contains a 55m high building, and the basement is about 6m, the pump reached in the basement height about 61m (common fire pump should be based on the highest floor of other low floor area, low ring and take in this case, relief measures) 61 levels, the most unfavorable hydrant to reach 0.07MPa (maximum allowable 0.5MPa) plus loss of lift at least about 90m more appropriate, of course can be higher to take relief measures (120 too high), the basic flow of lossless (with the same time there is only one building fire) according to the maximum amount of a building fire water pump set can be, there must be a backup with a preparation, and then select the appropriate pump manufacturer specification query.(the 20 houses on 99m are only shared with a 135m pump)
Q: If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
If the fish tank is made of metal, the fish tank is grounded or connected to the zero line, and then the fire line is put into the water, then your fish will be electrocuted immediately. Go back to the submersible pump, submersible pump line and the zero line very close, even if the firing line and the zero line at the same time the leakage occurs, fish could not swim between the firing line and the zero line, so the tank submersible pump leakage will cause the following hazards: 1, electric shock. 2, submersible pump short circuit. 3, the submersible pump serious fever, resulting in water temperature tank.
Q: What is double hydraulic pump?
The 2 pumps are all coaxial connected together, driven by a motor, the general gear pump, piston pump
Q: I would like to ask, constant pressure pump set pressure 20Mpa, the actual load is 15Mpa, then the constant pressure pump outlet pressure? If it is 20Mpa, then where is the loss of 5Mpa? If 15Mpa, the constant pressure pump 20Mpa how to understand? In addition, the constant pressure pump pressure is defined when the flow began to reduce the point, or a sharp drop in flow after the point?
The pressure loss is borne by the valve. Constant pressure pumps generally do not export direct load, unless you need this load response is very fast, then the maximum displacement of the pump work, so as to ensure the rapid response of the load.
Q: What kind of motor does the hydraulic pump need?
The motor should be determined according to the work environment, such as 220V.12V.24V.72V or 380V, and then the power.Calculation of actual oil pump power:
Q: Water pump spoon pipe for power plantWhich hero can tell me what is the water pump spoon tube ah? And its role
The spoon pipe is not a feed pump, but also is an adjusting oil inlet device of a hydraulic coupler matched with a feed pump
Q: Common failure treatment of piston pump
1) overflow valve regulation is too high, overload after the pump2) the overflow valve spool is blocked, the central hole of the valve core is blocked or the overflow valve is blocked by a damping hole, and the overflow is not overflow3) pump outlet one-way valve installed or spool blocked and stuffy pump4) motor fault x091) adjust the relief valve pressure value2) repair valve boring3) overhaul check valve4) overhaul or replace the motor
Q: Why does the centrifugal pump start with a closed valve and the axial pump starts with an opening valve?
The power of axial flow pump decreases with the increase of flow rate, and it is a steep curve, so the centrifugal pump starts with an open valve.
Q: What flowmeter is installed after the pneumatic diaphragm pump?
According to your entire pipeline system to flow meter ah!How about the pressure, the material, the digital float or what?You must be sure of the size of the flow
Q: How long does the fine stone pump need maintenance? What should I pay attention to?