W Vortex Pumps
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
W type vortex pump
1. Competitive price.
2. Low noise and steady.
3. High efficiency
4. Energy saving
W type vortex pump
1. It is widely used in chemical engineering, pharmacy,food,cigarette, and institute etc.
2. We can supply different good quality single-stage vortex pump.
3. Vortex impeller shaft can move freely along the axis to ensure that the impeller and pump body, pump cover gap between both sides of the same axis, allowing paper to adjust pad clearance. Seal whirlpool pump and fill the form of a single mechanical seal face two whirlpool pump and motor together in a common base.
Model | flow (m³/h) | head (m) | Power (kw) | pipe size | Voltage (v) | Velocity(r/min) | |
(mm) | 寸/lnch | ||||||
25W2.5-12 | 2.5 | 120 | 3 | 25 | 1 | 380 | 3000 |
40W-6.5-130(Valve) | 6.5 | 130 | 4 | 40 | 1.5 | 380 | 3000 |
40W-5-160(Valve ) | 5 | 160 | 7.5 | 40 | 1.5 | 380 | 3000 |
- Q:How much water does the water ring vacuum pump run for an hour? If there is no steam separator, does the water vaporize?
- For example: water storage is relatively small, it needs to reduce the temperature of the heat exchanger. If the tank is relatively large, it does not need cooling water circulation pump again when the temperature is very low, there is no need to heat exchanger. So you need to ask how much water this is not OK.In a soda separator problem:
- Q:Difference between pump and compressor
- Working principle:The impeller is installed in the pump casing and is fastened on the pump shaft 3, and the pump shaft is directly driven by the motor. There is a liquid suction in the center of the pump shell, and 4 is connected with the suction pipe 5. The liquid through the bottom valve 6 and the suction tube into the pump.The liquid discharge port 8 on the pump housing is connected with the discharge pipe 9. Before the pump starts, the pump shell is filled with the liquid to be transported; after starting, the impeller is driven by the shaft to rotate at high speed, and the liquid between the blades must also rotate. Under the influence of centrifugal force, the liquid is thrown from the center of the impeller to the outer edge and obtains energy, and leaves the outer edge of the impeller at high speed to enter the volute pump shell.
- Q:Centrifugal pumps for normal operation, is it reasonable to install valves on their inlet lines? Why?
- Submersible pump is best in the water, if dry pumping will cause burns.
- Q:When the water pump is started, why should it start when the outlet valve is closed? Thank you
- The valve opening pump is aimed at the centrifugal pump.From the power curve of the centrifugal pump, the power of the centrifugal pump increases with the increase of the flow rate; the flow curve of the centrifugal pump shows that the flow rate of the centrifugal pump decreases with the increase of the head.
- Q:A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
- According to the water quantity form fire flow water supply system fire safety in high-rise building fire hydrant pump lift is 10L/s, accurate algorithm is to say after a simple calculation with each indoor hydrant flow is two 5L/s bolt so to get the most unfavorable point for the calculation unit to calculate the minimum requirements, with the most unfavorable point suppository pressure specifications 0.07MPa, partial loss of the most unfavorable line and the line (according to the equivalent length) and loss (according to the material resistance coefficient), and finally the pump head loss of gravity difference. But we just calculate the construction elevation difference multiplied by 110% to 120% to determine the head {there is a need to know is: conversion head (m), (kg) and MPa kg 1MPa=10 kg = 100m is the vertical water column on unit area pressure conversion
- Q:Suction stroke and lift of water pump
- Lift pump lift pump can lift refers to the height, usually expressed in H, the unit is m. centrifugal pump lift to the impeller center line, divided by two parts. The vertical height from the pump impeller centerline to the water surface, the water pump to suck water up to the height, called water head, referred to as suction pump impeller; from the center line to the vertical height of the water tank, the water pump can put pressure on the height, called water pressure head, referred to as the pressure. The pump head = + suction head pressure water head should be pointed out that the nameplate marked head refers to the pump itself can produce lift, it is not with the pipe flow friction resistance caused by the loss of lift. In the selection of water pump, attention can not be ignored. Otherwise, will be pumping Sheung Shui.
- Q:How to calculate the motor power of metering pump?
- The motor power of the metering pump is divided into two parts1. mechanical power, this part of the power metering pump design part will be some data, mainly to control the mechanical structure of the metering pump required power
- Q:What is the liquid pump? What are their categories? What are their strengths and weaknesses?
- The liquid pump can be filled with oil, water and chemical medium. The gas drive range of the liquid pump is 1 to 10bar (14.5-145psi). The bottom piston is controlled by a two position four pass pilot valve.
- Q:What is the displacement of the pump? Flow? What is the volume efficiency and mechanical efficiency of the pump?
- Mechanical efficiency: the ratio of theoretical torque to actual torque of the pump.
- Q:Water pump outlet valve sequence
- To reduce the impact of vibration, noise and vibration on the valve, the soft connection is best at the pump outlet.The check valve is sometimes checked, so it is placed in front of the outlet valve so that the water can be checked out. I think the order should be: pump outlet, soft connection, check valve, gate valve (butterfly valve)
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
W Vortex Pumps
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords