Vertical Multistage Centrifugal Pumps With high quality
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 500 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
FEATURES:
Vertical Multistage grundfos water Pump is the latest model with the features of energy-saving and less space demand, easy to install and has stable performances.
1. With its 304 stainless steel shell and wear-resistant axle seal, there is no leakage and it can live long service life.
2. With hydraulic equilibrium to balance the axial force, the pump can run more smoothly, less noise, which can be easily installed in same level pipelines, enjoying better installation conditions than DL model.
3. With these features, GDL Pump can easily meet the needs and requirements for water supply and drain foe high building, deep well and firefighting equipments.
Flow range: 1.4-1 94.4CBM/h
Head range: 20-230m
Speed: 2900r/min
Maximal pressure of system: 2.5MPa
Medium temperature: -15~°C+120°C
Environment temperature: ≤+40°C
Motor protection level: IP44, IP54
Insulation grade: B, F rank
Rotation direction: Clockwise
APPLICATIONS:
Domestic water supply for buildings
Fire water supply for buildings
Water supply equipments
Water supply for boilers
Water circulation and boosting for industry
Other clean fluid transportation
- Q: Fire hydrant pump button, under what circumstances do not need to install?
- General high voltage system, when normal, use small pump steady pressure.Fire hydrant button lifting pump is one of the multiple pumping methods, and it is an important link of reliable operation of the system.
- Q: The water tank of the fish tank does not air out and only has the water outlet
- The water pump is cut off, the intake pipe is drawn out, and the water in the air pipe is blown out, then the water pump is put on the surface of the water, and the air inlet pipe is inserted on the surface of the water pipe, and then the water pump is put back into the water, and the water pump is electrified. Try again several times at a time. It should be effective.
- Q: What are the causes of pump shock?
- Troubleshooting cause1. bearing damage, replace new bearings2., coupling pin, bolt damage, rubber column or metal bolt wear, change
- Q: How many kilograms of water pump are there in the automatic washing machine on the market?
- High pressure pump pressure can reach 4--8kg, flow 5 liters, work current 4 or so.
- Q: What is the liquid pump? What are their categories? What are their strengths and weaknesses?
- The air driven liquid pump adopts compressed air driving method, and has the following advantages:The pressure can be adjusted by manual pressure control valve or air control valveIt is driven by air and is especially suitable for explosion protection applicationsAble to achieve pre-set final pressureAutomatic pressure relief by pumpLong term conservation without consuming energyWhen holding pressure, medium will not overheatThe utility model has the advantages of convenient installation and low maintenance cost, and only needs to connect the gas source, the inlet pipeline and the pressure pipelineReliable operation, low maintenance cost and little noise at the time of operation
- Q: What are the problems that should be paid attention to when using vacuum pumps?
- (1) check the vacuum pump line and the joint site regularly to see if there is any looseness. Turn the vacuum pump by hand and see if the vacuum pump is flexible.(2) add lubricating oil to the bearing body, observe the oil level at the center line of the oil mark, and the lubricant shall be replaced or supplemented in time.(3) plug screw vacuum pump of the water screw, filling water (or lead paste). (4) turn off the gate valve of the water outlet pipe and the outlet pressure gauge and the vacuum gauge. (5) point motor, and see if motor steering is correct.(6) start the motor. When the vacuum pump is in normal operation, open the outlet pressure gauge and the inlet vacuum pump. As soon as the proper pressure is shown, the gate valve is gradually opened, and the motor load is checked.
- Q: Centrifugal pump flow, why can be adjusted through the outlet valve? Can the flow of the reciprocating pump be adjusted in the same way?. Why
- First of all, we know that pump according to the principle of work is divided into speed and volume type, centrifugal pumps are speed type, and reciprocating pumps are volume type.The centrifugal pump can adjust the flow through the outlet valve and outlet valve opening can determine the pump flow and head performance curve parameters such as specific relationship between the outlet flow and pressure can be provided by the data pump manufacturers endplate that even close the outlet valve of the pump pressure will also have a fixed value, but not allow zero flow pump operation, vibration caused by damage to the pump on the mechanical seal is not good and so easy to cavitation, set the minimum reflux line.
- Q: Which nuclear submarines use the shaftless pump technology?
- Shaftless pumping technology and Simulation of shark skin technology are all the next generation of submarine propulsion technology. At present, there is no submarine in the world.
- Q: What are the differences between the sewage pump and the clean water pump?
- The main difference between the sewage pump and the clean water pump is that:Impeller and runner design, as well as other parts of the configuration are very different.1., in order to prevent clogging of sewage pump, the main design of large flow channel, so naturally lead to relatively low efficiency, so the head is generally not high. Clear water pump flow smaller, smaller clearance, the head is relatively high.
- Q: How long does the fine stone pump need maintenance? What should I pay attention to?
- Daily maintenance of concrete pump, that is, routine maintenance in use, including inspection, cleaning, lubrication, fastening, adjustment, leak hunting, supplement of hydraulic oil, etc.. 8.1 hydraulic components inspection, due to the complexity of the equipment, we recommend practical experts to carry out the inspection of hydraulic system. If a fault is found, check the cause and repair the entire loop before proceeding to any operation. - found that oil has diarrhea, excluding leakage reasons. - inspect safety valves, hydraulic systems, steel tubes and hoses, fittings, cylinders, and find any wear and tear (pipe explosion may cause very serious consequences)
Send your message to us
Vertical Multistage Centrifugal Pumps With high quality
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 500 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches