• submersible motor pump Amarex KRT INDUSTRY H, C1, C2 System 1
  • submersible motor pump Amarex KRT INDUSTRY H, C1, C2 System 2
  • submersible motor pump Amarex KRT INDUSTRY H, C1, C2 System 3
submersible motor pump Amarex KRT INDUSTRY H, C1, C2

submersible motor pump Amarex KRT INDUSTRY H, C1, C2

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
1 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

Design
Vertical, single-stage submersible motor pump made of wear-resistant                                                         industrial materials in close-coupled design, various impeller types,                                                           for wet or dry installation, stationary and transportable version. Design to ATEX.                                            
Applications
Handling of all types of abrasive or aggressive waste water in water and                                                     waste water engineering as well as industry, especially untreated sewage                                                        containing long fibres and solid substances, fluids containing gas /                                                            air, as well as raw, activated and digested sludge; sea water desalination.

 

Overview of technical data

Type of impeller                                                                         Open; Multi-vane impeller;Radial;Closed;Free flow impeller                    
Type of installation                                                                         Close- coupled                    
Maximum drive rating                                                                         200                         kW                    
Impeller material (EN standard)                                                                         JN 3029; 1.4517                    
Type of bearing                                                                         Rolling element bearings                    
Drive frequency                                                                         50 Hz / 60 Hz                    
Maximum speed of rotation                                                                         3. 500                         1/min                    
Maximum flow rate                                                                         2. 400                         m³/h                    
Maximum discharge-side pressure                                                                         10                         bar                    
Casing material (EN standard)                                                                         1. 4517;JN 3029                    
No. of impeller entries                                                                         Single entry                    
Casing material                                                                         White cast iron; Cast duplex steel                    
Suction characteristics                                                                         Non- priming                    
Drive voltage                                                                         Low voltage                    
eClass assignment                                                                         36410103; 36410101                    
Pump set location                                                                         Wet well                    
Explosion protection                                                                         ATEX II 2 G T3; ATEX II 2 G T4                    
Max. permissible fluid temperature                                                                         60                         °C                    
Free passage                                                                         120                         mm                    
Main applications                                                                         Water; Oil / Gas;Energy;Industry and process engineering;Mining / Dredges;Waste water / sewage                    
Type of installation                                                                         Stationary; Transportable                    
Type of casing                                                                         Volute casing                    
Type of connection                                                                         Flange                    
Type of lubrication                                                                         Oil lubrication                    
Type of drive                                                                         Electric motor                    
Installation position                                                                         Vertical                    
Shaft material (EN standard)                                                                         1. 4462;C45+N                    
Type of coupling                                                                         None                    
Shaft seal type                                                                         Mechanical seal                    
Drive                                                                         Electric motor                    
Maximum head                                                                         100, 00                         m                    
Maximum rated pressure (discharge)                                                                         PN 16                    
Nozzle position                                                                         End suction                    
Casing partition                                                                         Radially split                    
Connection to power supply                                                                         < 690 V, 3~
Q: How about the depreciation of vacuum pumps?
(a) housing and buildings for 20 years;(two) aircraft, trains, ships, machinery, machinery and other production equipment for 10 years;
Q: The suction pump has a nominal suction range of 30 metersHow deep can a well be sucked?Well, sixteen meters,
A standard atmospheric pressure can be 10.33 meters to 30 meters of water, suction is atmospheric pressure there are three standard atmospheric pressure so high? This is impossible in general, remove the vaporization removed 0.5 meters critical yo,
Q: How much water does the water ring vacuum pump run for an hour? If there is no steam separator, does the water vaporize?
The purpose of the steam separator is to separate the gas from the liquidWater ring type vacuum pump, water, compressed gas is discharged through the exhaust port, if not it is soda water separator is discharged, can not be separated, for the recovery of gas discharged industry is obviously impossible.Soda separator is available, the key is to see the working conditions
Q: What is the pump, how to classify, mainly used in where?
1. vane pumpThe impeller pump is driven by the impeller to rotate the liquid at high speed and transfer mechanical energy to the transported liquidAccording to the pump impeller and runner structure characteristics can be divided into different:1) centrifugal pump2) axial flow pump3) mixed flow pump4) vortex pumps3. jet pumpA high velocity jet produced by a working fluid is used to eject the fluid, and then the energy of the ejected fluid is increased by momentum exchange
Q: What is cavitation, centrifugal pump cavitation phenomenon how to solve?
First, what is cavitation?:When the centrifugal pump shell has air, it produces less centrifugal force because the density of the air is much smaller than the density of the liquid. Thus, suction pressure at the entrance to the top of the tank liquid level and pump is bad enough to the liquid storage tank into the pump, the centrifugal pump self suction capability, the centrifugal pump can not transport liquid, this phenomenon is called "cavitation".When a liquid drops at a certain temperature to the vapor pressure at that temperature, the liquid produces a bubble. The phenomenon of producing bubbles is called cavitation. When the cavitation bubbles, flow to the high pressure, the volume of reduced, so as to burst. This due to the pressure of rising bubbles disappear in the liquid in the phenomenon called cavitation bubble collapse.
Q: Concrete pump 125 pipe wall thickness
Concrete pump, also called concrete pump, consists of pump body and pipe. The utility model relates to a machine for continuously conveying concrete along a pipeline by utilizing pressure, which is mainly used for building, bridges and tunnels
Q: What is a positive displacement pump? He Weizheng displacement?
The principle and structure of displacement pumps are similar to those of hydraulic motors. Positive displacement is the pump outward to provide flow and pressure, that is, conventional pumps. A negative displacement pump is a hydraulic motor that rotates by external pressure and flow
Q: Is the sewage pump the same as the mud pump?
No. the main functions are different:1, pump two main performance parameters is the displacement and pressure, displacement from a number of liters per minute, with the diameter and the drilling fluid requirements from the hole on the back end of the speed, the larger aperture, the greater the displacement
Q: Types and differences of pumps
Classification and working principle of pump by structureClassification of pumpsInvolved pump standard product types are also very much, a centrifugal pump, metering pump, screw pump, reciprocating pump, hydraulic pump, submersible pump, oil pump, water pump, pressure test pump, vortex pump, cryogenic pump, vacuum pump, roots pump, molecular pump, gear pump, mud pump, corrosion-resistant pump deep well pump, water pump, mixed flow pump, axial flow pump, boiler feedwater pump, liquid pump, injection pump, chemical pump, pump plugging and no leakage pump, plastic pump, fire pump and so on, there are many. Its name is divided according to some conventional classification methods such as pump vane pump volume, pump etc., some are divided by purpose such as sewage pump, pump and other health, some names are more random as diffusion pump, liquid nitrogen pump. As long as the production of this product, with standard requirements, through a certain application and approval procedures may produce a new The standard, but sometimes the content also has a repeated cross, quite. The domestic and foreign standards, the domestic standard is more than the number of foreign standards. In general, such as centrifugal pumps are widely used, the production history of the pump more standard (total standard centrifugal pump up to more than 100). As new standard pump leakage pump this rapid development is relatively small. This paper introduces the structure and working principle of the pump according to the classification of the
Q: Centrifugal pumps for normal operation, is it reasonable to install valves on their inlet lines? Why?
Submersible pump is best in the water, if dry pumping will cause burns.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords