• submersible motor pump Amarex KRT INDUSTRY H, C1, C2 System 1
  • submersible motor pump Amarex KRT INDUSTRY H, C1, C2 System 2
  • submersible motor pump Amarex KRT INDUSTRY H, C1, C2 System 3
submersible motor pump Amarex KRT INDUSTRY H, C1, C2

submersible motor pump Amarex KRT INDUSTRY H, C1, C2

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
1 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

Design
Vertical, single-stage submersible motor pump made of wear-resistant                                                         industrial materials in close-coupled design, various impeller types,                                                           for wet or dry installation, stationary and transportable version. Design to ATEX.                                            
Applications
Handling of all types of abrasive or aggressive waste water in water and                                                     waste water engineering as well as industry, especially untreated sewage                                                        containing long fibres and solid substances, fluids containing gas /                                                            air, as well as raw, activated and digested sludge; sea water desalination.

 

Overview of technical data

Type of impeller                                                                         Open; Multi-vane impeller;Radial;Closed;Free flow impeller                    
Type of installation                                                                         Close- coupled                    
Maximum drive rating                                                                         200                         kW                    
Impeller material (EN standard)                                                                         JN 3029; 1.4517                    
Type of bearing                                                                         Rolling element bearings                    
Drive frequency                                                                         50 Hz / 60 Hz                    
Maximum speed of rotation                                                                         3. 500                         1/min                    
Maximum flow rate                                                                         2. 400                         m³/h                    
Maximum discharge-side pressure                                                                         10                         bar                    
Casing material (EN standard)                                                                         1. 4517;JN 3029                    
No. of impeller entries                                                                         Single entry                    
Casing material                                                                         White cast iron; Cast duplex steel                    
Suction characteristics                                                                         Non- priming                    
Drive voltage                                                                         Low voltage                    
eClass assignment                                                                         36410103; 36410101                    
Pump set location                                                                         Wet well                    
Explosion protection                                                                         ATEX II 2 G T3; ATEX II 2 G T4                    
Max. permissible fluid temperature                                                                         60                         °C                    
Free passage                                                                         120                         mm                    
Main applications                                                                         Water; Oil / Gas;Energy;Industry and process engineering;Mining / Dredges;Waste water / sewage                    
Type of installation                                                                         Stationary; Transportable                    
Type of casing                                                                         Volute casing                    
Type of connection                                                                         Flange                    
Type of lubrication                                                                         Oil lubrication                    
Type of drive                                                                         Electric motor                    
Installation position                                                                         Vertical                    
Shaft material (EN standard)                                                                         1. 4462;C45+N                    
Type of coupling                                                                         None                    
Shaft seal type                                                                         Mechanical seal                    
Drive                                                                         Electric motor                    
Maximum head                                                                         100, 00                         m                    
Maximum rated pressure (discharge)                                                                         PN 16                    
Nozzle position                                                                         End suction                    
Casing partition                                                                         Radially split                    
Connection to power supply                                                                         < 690 V, 3~
Q: How about the depreciation of vacuum pumps?
(a) housing and buildings for 20 years;(two) aircraft, trains, ships, machinery, machinery and other production equipment for 10 years;
Q: What are the starting and stopping procedures for centrifugal pumps?
The use of centrifugal pump can be divided into three steps, namely, start, run, stop.Start: you should do the following preparation before starting:(1) check the water pump equipment in good condition.(2) the bearings are filled with oil, the oil level is normal, and the oil quality is qualified(3) all the inlet valves of the centrifugal pump are opened.(4) pump water injection or vacuum pump diversion (except for flow), open the vent valve exhaust.(5) check the leakage of shaft seal. It is advisable to fill the seal with a little drop of water.(6) the motor rotates in the right direction.
Q: Excuse me, what is the water pump from the lotus root?
The pump is automatically coupled by the self coupling device to move downwards along the guide rod to the position, thereby achieving the simple and convenient effect. There's no need to jump into the septic tank when it's time to repair.When you buy a sewage pump, a professional person will ask you what kind of installation you need!
Q: I live on the 8 floor. Often there is no water. Life is very inconvenient. What kind of pump do I have to install? What should I pay attention to when I buy it? What's the pump for that brand? Should it be installed in that position?
Installation method of hydraulic pump(1) according to the technological requirements and the cavitation conditions of the pump, the installation height check and the civil engineering of the foundation are carried out.(2) prepare a series of flat washers and wedge gaskets of different thickness before installation.(3) according to the characteristics of the pump conveying medium, determine the material of the gasket at the connection and process the gasket.
Q: Operating procedures for measuring pumps
3, discharge pipeline unimpeded.4, the pipeline should meet the positive pressure head, that is, in high flow suction conditions work.5, check the direction of the pump, strictly prohibited reverse.6. Check the oil level in the crankcase compartment. For multi cylinder pumps, check that the oil level has reached the required level.7 、 pump motor static grounding is good, meet the requirements.
Q: Is the sewage pump the same as the mud pump?
The upstream return speed of the washing fluid is required to remove the cuttings and rock powder from the drill in a timely manner from the bottom of the hole and reliably carry it to the surface. Through drilling and extraction, mud can be obtained at the bottom.
Q: What are the constant pressure pumps?
Chlorine booster pumpThe pressure range of chlorine booster pump is large, and different pump can be used to obtain different pressure area. The input air pressure is adjusted and the output pressure is adjusted accordingly. High pressure can be reached, gas 90Mpa. Wide range of flow, for all types of pumps only 0.1Kg pressure can work smoothly, at this time to obtain the minimum flow, adjust the intake volume can be obtained after a different flow. Easy to control, from simple manual control to fully automatic control, can meet the requirements. Automatic restart, regardless of what causes the pressure drop in the pressure loop, will automatically restart to supplement leakage pressure and maintain constant loop pressure. Safe operation, gas driven, no arc and spark can be used in dangerous situations.
Q: Roots pump and dry pumpRecently involved in the work of the vacuum pump, don't understand this, is a ads602 vacuum pump, composed of roots pump and dry pump, is pre pumped to the 500mtorr equipment, the main pumping vacuum continues to 10mtorr, where the roots pump and dry pumps must be used? What role they play respectively. The so-called dry pump? Is refers to one kind of the pump, the pump is many dry pump? Also do not understand how the work of automatic switching system for pre pumping, the main pump, pump work alone did not connect system ah (of course there are even a butterfly) teach?
Here the roots pump and dry pump must be used, because the roots pump is not used alone, and must be a stage vacuum pump (pre vacuum pump can be dry pump, water ring vacuum pump and rotary vane vacuum pump can be, you here with dry pump series)
Q: What is an industrial water pump?
Classification by usagePump, circulating pump, fire pump, pressure test pump, sewage pump, metering pump, sanitary pump, dosing pump, pump, pump, gelatinization defoaming pump, flow pump, oil pump, water pump, drainage pump, drainage pump, dredging pump, sprinkler pump, booster pump, high pressure pump, heat pump high temperature, low temperature, pump pump, condensate pump, heat pump, cooling pump, heating pump, deep well pump, analgesic pump, pump, pump, chemotherapy, blood pump material pumping pump, pump, pump, sulfur removal, shearing grinding pump fuel pump, pump, pump, quillback bath source heat pump, filter pump oxygen pump, pump, shampoo, injection pump, air pump, gas pump, pump, pump, art odorization pump chopped
Q: Attention should be paid to the use of pumps?
1, pump shaft packing completely worn, it is necessary to add in time, if you continue to use the water pump will leak. The direct effect of this is the increased energy consumption of the motor, which will damage the impeller. 2, the use of pumps in the course of a strong vibration, then must stop to check the reasons, or the same will cause damage to the water pump. 3 gear pump valve Water Leakage, some will use the soil into the water pump inlet tube, the water washed in the end valve, this is indeed undesirable. Because when the dry soil into the inlet pipe, when the pump started working, these dry soil will enter the pump, which will damage the pump impeller and bearings, which shorten the service life of the pump. When the valve Water Leakage must take to repair, if it is serious that it is necessary to replace the new. 4 after the use of pumps must pay attention to maintenance, for example, when the pump is exhausted, we should put the water pump who put clean, it is best to remove the water pipe, and then rinse with water. 5 water pump on the tape should also be written down, and then always flush, and then light out to dry, do not put the tape in the dark damp place. Water pump tape must not be stained with oil, not to tape coated with some sticky things.