Product Introduction:
1. WCB Stainless steel oil transfer gear pump is a small gear oil pump with a portable handle.
2. This series of pump is always used to delivery lubricating liquid, but by adopting stainless steel material, it also works for medium that is non-lubricating oil, beverage or corrosive liquid.
3. With the merits of small volume and easy to move and carry, pump has always been used in oil drum carrier, oil refinery, electric power plant and substation and oil depot.
4. The voltage and frequency could be customized to meet customers' requirements.
Product details:
Working Principle: | Double Gears |
Main applications: | Oil |
Driver: | Electric motor |
Power Specs: | 380/415 V 3phase; 110V/220/240 V 1phase;50hz/60hz,etc |
Max. permissible fluid temperature: | 120°C(248°F) |
Type of connection: | Thread, Quick couple. |
Installation position: | Horizontal |
Casing parts material: | Cast iron, Stainless Steel |
Shaft seal type: | Shaft seal ring |
Free passage: | 00 mm |
Maximum viscosity: | 300C.S.T |
Maximum drive rating: | 1.1kW(1.5HP) |
Maximum caliber: | 25mm(1inch) |
Maximum discharge-side pressure: | 0.3MPa(3bar) |
Maximum suction | 5m(16.4ft) |
Flow rate range: | 30-100L/min(7.9-26.4US.GPM) |
Performance data:
Model | | Caliber | Capacity | Head | Motor power | Voltage |
| | (mm) | (L/min) | (m) | (W) | (Phase) |
WCB-30 | Cast iron | 20 | 30 | 30 | 370 | 1ph/3ph |
WCB-50 | | 20 | 50 | 30 | 550 | 1ph/3ph |
WCB-75 | | 25 | 75 | 30 | 750 | 1ph/3ph |
WCB-100 | | 25 | 100 | 30 | 1100 | 1ph/3ph |
WCB-30P | Stainless steel | 20 | 30 | 30 | 370 | 1ph/3ph |
WCB-50P | | 20 | 50 | 30 | 550 | 1ph/3ph |
WCB-75P | | 25 | 75 | 30 | 750 | 1ph/3ph |
- Q: Why does the centrifugal pump close the pressure to start?
- The motor power is selected according to the rated flow of shaft power points plus 15 to 25%, if the outlet valve is fully open to start, the pump flow may deviate from the amount of fixed lot, pump efficiency also reduces a lot, resulting in shaft power greater than the motor power caused by tripping even burned electric machine.
- Q: The water tank of the fish tank does not air out and only has the water outlet
- The picture above is very clear, but I didn't say anything about it. My problem is solved. The intake pipe and the exhaust pipe are connected by the inverted T type. The intake pipe is upward, but not fixed. It can be rotated. The intake pipe can be rotated to adjust the number of bubbles
- Q: What are the characteristics of a pipe shield pump?
- Two, reverse circulation type of shielding pump, its bearings, lubrication, cooling and motor cooling fluid flow direction and the basic type is the opposite. The main characteristic of reverse circulation pump is that it is not easy to generate cavitation. It is suitable for conveying liquid which is easy to vaporize. Sometimes it is also called "easy to vaporize" type. Three, high temperature medium temperature of up to 450 degrees. The cooling water jacket is usually added outside the shielding motor, and a cooling sleeve is added to the outer circulation pipe to cool the high temperature circulating liquid to reduce the temperature of the motor and the bearing. In the case of less power, some manufacturers do not use cooling liquid, but the outside of the motor is equipped with fins and the special winding to adapt to the working conditions, the use of temperature generally can not exceed 400 degrees.
- Q: Pump unloading in hydraulic transmission,
- Unloading is pumping oil directly back to the tank, the pressure is very low, energy saving
- Q: Double floor sewage pump circuit diagram of a small problem
- Question 4 when you need backup, you need to switch the SA switch, but where you want it. For example, when the 1# pump is running and does not reach the high water level, the 2# pump will not operate. If SA is placed in the left position, 21 and 22 are connected, and the KT is electrically delayed, and the KAB action causes the 2# pump to function. After the KAB operation, the KT will be disconnected, restored to the ready state, and also convenient for KT to restart the power on time, and also avoid the time relay to work on a long-term basis.
- Q: How to install, operate and maintain the pipeline booster pump?
- When the pump leaks, check it immediately to prevent leakage. If it leaks with the motor connection, replace the mechanical seal. Check that the power is connected. Is the supply voltage consistent with the operating voltage of the pump?. If the above a and B are normal, please remove the pump, open the pump cover, remove the foreign body in the pump, and then pump the lid on, and then tighten it to normal.No water pump, pump installed in the tap water pipeline, such as tap water level in the pump impeller on the plane (horizontal installation) or center line (vertical) below, you should turn off the power supply, to tap water level rise more than the impeller plane or the center line, connected to the power supply, to avoid mechanical damage (automatic no need to turn off the electric type). When the pump used in pumping wells, please check whether the water inlet pipe leak; pump cavity storage is not enough, should be filled with water, whether the suction process is too high, proper adjustment. Check whether the inlet and outlet diameter is too small or blocked. Automatic type after a period of time, there may be automatic failure phenomenon, mainly stainless steel and other metal products in pipes, long-term precipitation to shut off the power supply after unloading, unscrew the top screw, remove the plastic sheet to be cleaned, and then, according to the original reset, the normal debugging, can be re used.
- Q: What are the starting and stopping procedures for centrifugal pumps?
- Before using the centrifugal pump, the operation instructions of the centrifugal pump shall be read carefully and the specific operation procedures shall be understood so as to make proper use of the centrifugal pump products. The first step is the operation of centrifugal pump inlet valve of centrifugal pump centrifugal pump for all open cavity filled with liquid, close the outlet valve, start the motor, the motor speed is normal, can gradually open the outlet valve, to adjust to the desired condition. Pay attention to self suction centrifugal pump starts to open the exhaust valve, outlet valve should be opened quickly in the normal operation of the motor, to prevent air inlet pipe off caused by cavitation phenomenon produces centrifugal pump, centrifugal pump vibration phenomenon leads to noise of the smoke is not on the water.
- Q: What are the characteristics of a vertical multistage centrifugal pump?
- Vertical multistage centrifugal pump system using the latest international advanced IS type hydraulic model based design for high efficiency centrifugal pump with multi segment, the soft packing or mechanical seal, has the characteristics of high efficiency, large flow, high lift, no leakage, a wide range of performance, safe operation, stable operation and long service life and small area.
- Q: Why is the flow of the pump too small will occur cavitation phenomenon?
- This is because the impeller of the centrifugal pump rotating speed under the drive of the prime mover, when the valve opening decreases, flow rate is too low, can not be taken away by the friction heat generated by the impeller and the liquid completely, make the temperature of the liquid inside the pump. Thus causing liquid vaporization, forming cavitation. Especially in the power plant, the boiler feed pump is more remarkable. Therefore, when throttling regulation, we should set up recirculation system, increase the output flow of the pump to prevent cavitation. When the feed water rate is reduced to 1/3 of the maximum flow rate, the recirculating gate shall be opened so that the flow of the feed pump will be increased properly to ensure that the liquid temperature in the feed pump does not rise.
- Q: Filter backwash pump for what use, what is the principle of work ah?
- But the reverse cleaning can not completely regenerate the filter medium, or there will be some impurities remain, when the regeneration of residual impurities (pressure drop) to set the value, you need to replace the filter (filter media).
Send your message to us