Solar Centrifugal Pump System
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
You Might Also Like
Specifications
1.MPPT and DSP chip technique2. brushless DC motor.
4.C&U bearing
Basic Info.
Model NO.:30M-40M-50M head solar DC pump
Power:Solar
Structure:Screw Pump
Theory:Solar Pump
Type:Blade Pump
Application:Submersible Pump
Material:Stainless Steel
Export Markets:Global
Additional Info.
Packing:Carton
Origin:China
HS Code:8413709190
Production Capacity:5000PCS/Month
Product Description
Solar submersible pump including:
1. Solar panel (Monocrystalline silicon or Polycrystalline silicon)
2. DC pump
3. MPPT DC pump controller
4. Centrifuga;
5. Cable connector,
6. Water level sensor,
Technology Specification
1. Voltage: DC110V
2. Motor power: 1300W
3. Flow rate: 23-46m3/h
4. Head: 20M-e0M
5. Water Outlet Diameter: 3"&4"
- Q: Fire hydrant pump button, under what circumstances do not need to install?
- The installation of hydrant pump buttons depends on the type of water supply:(1) municipal water supply; (in this case, do not have to install)(2) there is a fire pump; (must be installed)
- Q: What is a solution pump?
- (4) smooth running, low noise, no lubrication, no lubrication and low noise due to the absence of rolling bearings and motor fans(5) a wide range of use, the high temperature, high pressure, low temperature, high melting point and other conditions are able to meet the requirements2.2 shielding pump shortcomings(1) because the shielding pump adopts sliding bearings and is lubricated by the medium to be transported, the medium with poor lubricity should not be transported by shielding pump. Generally, the viscosity of the pump medium is 0.20mPa.s.(2) the efficiency of shielding pump is usually lower than that of single end mechanical seal centrifugal pump, which is approximately equal to that of double end mechanical seal centrifugal pump(3) long time in small flow operation, shielding pump efficiency is low, will lead to heat, make the liquid evaporation, and cause the pump to dry, and thus damage the sliding bearingsCanned pumps can be divided into the following types: 1) basic type 2) reverse circulation type 3) high temperature type 4) high melting point type 5) high pressure type6) self priming 7) multi stage 8) mud type
- Q: If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
- If the fish tank is made of metal, the fish tank is grounded or connected to the zero line, and then the fire line is put into the water, then your fish will be electrocuted immediately. Go back to the submersible pump, submersible pump line and the zero line very close, even if the firing line and the zero line at the same time the leakage occurs, fish could not swim between the firing line and the zero line, so the tank submersible pump leakage will cause the following hazards: 1, electric shock. 2, submersible pump short circuit. 3, the submersible pump serious fever, resulting in water temperature tank.
- Q: What is double hydraulic pump?
- [double hydraulic pump] the same drive shaft drives the rotation of two pumps, which are connected together and driven by an electric motor. The suction port of the pump is common, and the oil pressure port is separated from each other. Pump output of two shares of flow can be used alone, can also be used in parallel. This pump, a pump can play the function of two pumps. For example, there are two pumps on the loader, a pump acting as the work, a pump acting as the steering, and the double linked pump can replace the functions of the two pumps. It works by coupling the two pumps at the same time.
- Q: How to install, operate and maintain the pipeline booster pump?
- Should be "People's Republic of China network security law" requirements, since June 1, 2017, the use of Internet services to carry out real name authentication account. In order to ensure your Baidu account can be used normally, please check the account number as soon as possible. Thank you for your understanding and support.How to install, operate and maintain the pipeline booster pump?Brother Yao s Gc76 2547 | browseRecommended for 2016-12-01 23:52:54 best answerThe installation of booster pump must be installed horizontally or vertically according to the installation method. The direction of flow shall be consistent with the arrow on the pump body, and installed as far away from the water level as possible. A valve shall be installed on the pump inlet line for ease of use and maintenance. When the impeller is the aspiration level below the pump on the pump shaft end or around the pump should be installed check valve, the outlet is connected with 13 links for water use, at first use to pump should be filled with water, and tighten the screw plug. The pipe connection should be tight, especially the water inlet pipe can not leak, otherwise it will reduce the pump head or not pumping water. The pump cavity is not water, not a long time running, so as not to damage the seal
- Q: Rules for operation of centrifugal pumps
- Working principle and process flowWorking principle: when the drive motor with high-speed rotating impeller, full of fluid in the pump body under the action of centrifugal force, was thrown from the impeller center to the outer edge of the impeller, in this process, the fluid energy, improve the pressure can, at the same time also increases the energy flow rate increase. The liquid from entering the pump impeller shell, the liquid flow gradually widened, the liquid velocity decreased gradually, which will be part of the kinetic energy into pressure energy, which further improves the static pressure of liquid, and liquid with high pressure in pressure pipeline. When the liquid from the leaves out when the impeller center creates pressure and low pressure than the out plane is big, under pressure drive, liquid is continuously from the center of the impeller suction, with the pressure of continuous discharge.
- Q: What are the main performance parameters of hydraulic pumps?
- speedOperating speed is the actual rotation speed of a pump (or motor) at work.Rated speed is the maximum speed that can operate normally for a long time under rated pressure. If the pump exceeds the rated speed, the work will cause insufficient oil absorption, vibration and noise, the parts will suffer cavitation damage, life expectancy.Minimum steady speed is the minimum speed allowed for normal motor operation. At this speed, the motor does not appear crawling phenomenon.
- Q: Pump operator's responsibility 10Sharing the rules, responsibilities, etc..
- 1., consciously abide by the traffic control department management rules, to achieve civilized driving, safe driving.2. responsible for the daily maintenance, cleaning and cleaning of the pump truck, and ensure the equipment is in good condition.
- Q: What is the pumping property of concrete?
- Pumpable concrete slump is generally greater than 160mm, the mortar content is too low, the maximum aggregate size of not more than 1/3 of the diameter of the pump pipe, sending process segregation, plugging in the pump.
- Q: Centrifugal pump flow, why can be adjusted through the outlet valve? Can the flow of the reciprocating pump be adjusted in the same way?. Why
- Reciprocating pump is a positive displacement pump, the volume change of flow is the unit of time, constant flow speed constant, can not rely on increased resistance to change the flow resistance increase is only leaked, only small changes in flow.
Send your message to us
Solar Centrifugal Pump System
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches