Small 5hp ZX type 3 inch self priming centrifugal diesel engine pump
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 100 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Products Introduction
Data:
1.Flow rate (Q)3.2-550m3/h
2.lift head (H) : 20-80m
3.Suction lift: 5-6.5m
4.Rotatory speeed:1450/2900r/min(1800/3600)
5.Suction performance:1.2-3.4 min/5m
6.Shaft power:0.46-126kw
7.Motor power:0.75-132kw
8.Brass or bronze SS304 316 impeller
9.Cast iron SS304 316 pump body
PUMP name: Small 5hp ZX type 3 inch self priming centrifugal diesel engine pump
Summarize:
ZX centrifugal self-priming water pump(diesel water,self-priming pump,water pump,self-priming polluted water pump,pump) are newly developed self-priming centrifugal pumps for clean water or chemicals. The pumps have the compact structure, the high energy-efficiency to operate smoothly and reliably, the long life expectancy. It is just need to check the amount of liquid in the pump for self-priming before starting pump
1) Detailed instructions
2) Application Area
The self-priming centrifugal pumps are widely used for applications in the chemical, dye stuffs, petroleum, pharmaceutical, brewery, paper and pulp, metallurgical and mining industries and for oil discharge of oil carrying ships, as well as for water supply and sewage drainage of municipal industrial and emergence services.
3)Industries Served
♦ Construction | ♦ Industrial | ♦ Municipal |
♦ Agricultural | ♦ Mining | ♦ Dewatering |
♦ Industrial Waste | ♦ Sewage | ♦ Oil Field |
♦ Petrochemical | ♦ Paper Mills | ♦ Processing |
4)Parameter
Model | Flow capacity | Head (m) | Suction lift(m) | Rotary speed (r/min) | Self-priming performance min/5m | Power KW | ||
(m3/h) | L/S | Shaft power | Motor power | |||||
25ZX3.2-20 | 3.2 | 0.9 | 20 | 6.5 | 2900 | 1.9 | 0.46 | 0.75 |
25ZX3.2-32 | 3.2 | 0.9 | 32 | 6.5 | 2900 | 1.8 | 0.8 | 1.1 |
40ZX6.3-20 | 6.3 | 1.8 | 20 | 6.5 | 2900 | 1.9 | 0.87 | 11 |
40ZX10-40 | 10 | 2.8 | 40 | 6.5 | 2900 | 1.5 | 2.7 | 4 |
50ZX15-12 | 15 | 4.2 | 12 | 6.5 | 2900 | 2.4 | 1.1 | 1.5 |
50ZX18-20 | 18 | 5 | 20 | 6.5 | 2900 | 1.9 | 1.8 | 2.2 |
50ZX12.5-32 | 12.5 | 3.5 | 32 | 6.5 | 2900 | 1.5 | 2.1 | 3 |
50ZX20-30 | 20 | 5.6 | 30 | 6.5 | 2900 | 1.5 | 2.6 | 4 |
50ZX14-35 | 14 | 3.9 | 35 | 6.5 | 2900 | 1.5 | 2.7 | 4 |
50ZX10-40 | 10 | 2.8 | 40 | 6.5 | 2900 | 1.5 | 2.7 | 4 |
50ZX12.5-50 | 12.5 | 3.5 | 50 | 6.5 | 2900 | 1.4 | 4.3 | 5.5 |
50ZX15-60 | 15 | 4.2 | 60 | 6.5 | 2900 | 1.3 | 6.2 | 7.5 |
50ZX20-75 | 20 | 5.6 | 75 | 6.5 | 2900 | 1.3 | 9.8 | 11 |
65ZX30-15 | 30 | 8.3 | 15 | 6.5 | 2900 | 2 | 1.9 | 3 |
65ZX25-32 | 25 | 6.9 | 32 | 6 | 2900 | 1.5 | 4.4 | 5.5 |
80ZX35-13 | 35 | 9.7 | 13 | 6 | 2900 | 3.4 | 1.9 | 3 |
Samply available: 7~10days.
Qty: 1pc, only pump head is provided.
Price: US$100~200
OEM is welcome
OEM expierence: more than 10 years.
Countries: Germany, U.S.A, Spain, Italy, United Kingdom etc
Warranty: the whole pump is guaranteed within 1 year, the pump's spare parts are guranteed for 3 months from the date of delivery.
For more information, please do not hesitate to contact me.
The information should be including inquiry as following:
1.Pump's flow rate
2.Pump's Head (Pressure
3.Driven Mode: By electric motor or diesel engine or bare shaft etc
4.Power and rotary speed
5.Suction lift for self priming pump
6.Temperature of liquid if you can provide
Upon the receipt of the pump's parameter, we can send our quotation to you within 24 hours.
Or the condition of pump station would be provided.
♦FAQ:
1. Q: Can I know more about your products?
A: Pls view our website: www.lanco.cc.
2. Q: What’s your MAQ of this item?
A: 1~2PCS
3. Q: What is the lead time?
A: 10~30 days after receiving your payment,depends on pumps.
4. Q: where is your loading port?
A: Ningbo, China port
5. Q: Are you a manufacturer or trading company
A: We are a manufacturer specialize in water pump and other pumps more than 20 years.
For more information, please contact me.
- Q: What are the general water pump failure, how to repair?
- (2) in contact with the water pump inlet of the horizontal application of reverse flow direction, fell more than 0.5% slope, connect one end of the highest import pumps, do not completely level. If the upward tilt, the intake pipe will retain air, reducing the water pipes and pumps in the vacuum, water absorption.
- Q: How many millimeters is the diameter of the water outlet of the four inch pump?
- This question is of no practical significance. The user does not care about this figure. The concern should be the nominal diameter, which is fitted with flanges and pipes. Moreover, the pump shell is cast iron, the inside diameter is not processed, and there is no matching parts, there is only one manufacturing size.
- Q: The difference between diaphragm pumps, vacuum pumps and centrifugal pumps
- The diaphragm pump and centrifugal pump refer to the structure of the pump, and the vacuum pump means the use of the pump. There is no comparability between them.Centrifugal is the sign of inertia of an object. As the umbrella turns, water droplets move out of the outer edge of the umbrella and are thrown out. This is what is called centrifugal. Centrifugal pump is designed according to this principle. The high speed rotating impeller blade drives the medium to rotate and is thrown out so as to achieve the purpose of conveying.
- Q: What is double hydraulic pump?
- The 2 pumps are all coaxial connected together, driven by a motor, the general gear pump, piston pump
- Q: Fire control center manually start the fire pump directly, multi line control, called straight up line NHKVV-7*1.5, my understanding is: straight line from fire control center
- Multi line linkage NHBVR-4*1.5 is a positive pressure blower and smoke exhaust machine fire fighting equipment
- Q: What's the difference between non negative pressure and variable frequency water pump?
- When peak water is used, the fluctuation of water pressure will be the same for customers! Because the key to the fluctuation of hydraulic pressure is the flow rate of the pump and the lift of the pump. As long as the flow of the selected pump is large enough, the tank is large enough, the lift head is suitable, and the pressure fluctuation is relatively small. And the selection of non negative pressure and frequency conversion pump group is not directly related. If the municipal tap water pressure and water sufficient (large enough diameter), the use of non negative pressure is better. If the municipal tap water pressure and water shortage, you can only use the frequency converter pump + water tank, no negative pressure can not be used.
- Q: Please give me professionals to calculate, the cylinder bore is 100 and the rate of 20m/s, the leakage can be ignored, but to the large flow pump!
- Select the hydraulic pump from the following considerations:1. hydraulic pump pressureHydraulic pump operating pressure is the pump (or motor) in actual work output (or input) oil pressure, determined by the external load.Rated pressure refers to the maximum pressure under continuous running in accordance with the test standards under normal working conditions. The size of the pump is limited by the service life, and the service life of the pump (or motor) will be shorter than the design life if it exceeds the rated pressure. When the work pressure is greater than the rated pressure, it is called overload.
- Q: Working principle and structure of external gear pump
- The principle of the gear pump, gear pump structure consists of two gear mesh together with each other, and composed of pumps known as gear pumps. It relies on the gear teeth meshing space change in volume to transport the liquid, it belongs to the rotary pump, also can be considered as a volume pump. There are many kinds of gear pumps. According to the meshing mode, it can be divided into external gear pump and internal gear pump. According to the tooth shape of gear, it can be divided into positive gear pump, helical gear pump and herringbone gear pump.
- Q: Metering pumps related matters
- Rotate to stroke length 100% position. This allows the kit to rotate to the back of the drain hole and align the bottom of the pump. Adjust the hydraulic end and diaphragm to the proper position during the pump operation.The duration of the pulse may not be long enough for the reaction time. With respect to the standard pulse width 80msec, the flow monitor pulse width expansion can be activated, increasing the pulse width to 300msec. Activate the smart switch, remove the cover fixed circuit board, remove the jumper X-1. This activates the extended function and allows more time before the failure instructions.Metering pump installed from the exhaust pump head, the use of self suction liquid imbibition. Keep the suction line as short as possible.
- Q: What flowmeter is installed after the pneumatic diaphragm pump?
- Compressed air source, the general pneumatic diaphragm pump starting gas source for 0.1~0.2mpa,The maximum working pressure is 0.7~0.8mpa, so in this pressure range, you can use the air filter relief pressure valve gas pipe, adjusting for air pressure, when the pressure is bigger, diaphragm movement faster, so the greater the flow, and vice versa
Send your message to us
Small 5hp ZX type 3 inch self priming centrifugal diesel engine pump
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 100 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords