Data:

1.Flow rate (Q)3.2-550m3/h


2.lift head (H) : 20-80m


3.Suction lift: 5-6.5m


4.Rotatory speeed:1450/2900r/min(1800/3600)


5.Suction performance:1.2-3.4 min/5m


6.Shaft power:0.46-126kw


7.Motor power:0.75-132kw


8.Brass or bronze SS304 316 impeller


9.Cast iron SS304 316  pump body


PUMP name: ZX 3 inch self priming centrifugal diesel engine clean water pump

Summarize:

     ZX centrifugal self-priming water pump(diesel water,self-priming pump,water pump,self-priming polluted water pump,pump) are newly developed self-priming centrifugal pumps for clean water or chemicals. The pumps have the compact structure, the high energy-efficiency to operate smoothly and reliably, the long life expectancy. It is just need to check the amount of liquid in the pump for self-priming before starting pump  

1) Detailed instructions

2) Application Area

           The self-priming centrifugal pumps are widely used for applications in the chemical, dye stuffs, petroleum, pharmaceutical, brewery, paper and pulp, metallurgical and mining industries and for oil discharge of oil carrying ships, as well as for water supply and sewage drainage of municipal industrial and emergence services.

3)Industries Served

♦ Construction

♦ Industrial

♦ Municipal

♦ Agricultural

♦ Mining

♦ Dewatering

♦ Industrial Waste

♦ Sewage

♦ Oil Field

♦ Petrochemical

♦ Paper Mills

♦ Processing


4)Parameter

Model
Flow capacity
Head
(m)
Suction
lift(m)
Rotary
speed
(r/min)
Self-priming
performance
min/5m
Power
KW
(m3/h)
L/S
Shaft
power
Motor
power
25ZX3.2-20
3.2
0.9
20
6.5
2900
1.9
0.46
0.75
25ZX3.2-32
3.2
0.9
32
6.5
2900
1.8
0.8
1.1
40ZX6.3-20
6.3
1.8
20
6.5
2900
1.9
0.87
11
40ZX10-40
10
2.8
40
6.5
2900
1.5
2.7
4
50ZX15-12
15
4.2
12
6.5
2900
2.4
1.1
1.5
50ZX18-20
18
5
20
6.5
2900
1.9
1.8
2.2
50ZX12.5-32
12.5
3.5
32
6.5
2900
1.5
2.1
3
50ZX20-30
20
5.6
30
6.5
2900
1.5
2.6
4
50ZX14-35
14
3.9
35
6.5
2900
1.5
2.7
4
50ZX10-40
10
2.8
40
6.5
2900
1.5
2.7
4
50ZX12.5-50
12.5
3.5
50
6.5
2900
1.4
4.3
5.5
50ZX15-60
15
4.2
60
6.5
2900
1.3
6.2
7.5
50ZX20-75
20
5.6
75
6.5
2900
1.3
9.8
11
65ZX30-15
30
8.3
15
6.5
2900
2
1.9
3
65ZX25-32
25
6.9
32
6
2900
1.5
4.4
5.5
80ZX35-13
35
9.7
13
6
2900
3.4
1.9
3
Our Services

 Samply available: 7~10days.
Qty: 1pc, only pump head is provided.
Price: US$100~200
OEM is welcome
OEM expierence: more than 10 years.
Countries: Germany, U.S.A, Spain, Italy, United Kingdom etc
Warranty: the whole pump is guaranteed within 1 year, the pump's spare parts are guranteed for 3 months from the date of delivery.
For more information, please do not hesitate to contact me.

FAQ


The information should be including inquiry as following:
1.Pump's flow rate
2.Pump's Head (Pressure
3.Driven Mode: By electric motor or diesel engine or bare shaft etc
4.Power and rotary speed
5.Suction lift for self priming pump
6.Temperature of liquid if you can provide
Upon the receipt of the pump's parameter, we can send our quotation to you within 24 hours.

Or the condition of pump station would be provided.

♦FAQ:

1.   Q: Can I know more about your products?

       

        A: Pls view our website: www.lanco.cc.

2. Q: What’s your MAQ of this item?

        A: 1~2PCS

3. Q: What is the lead time?

        A: 10~30 days after receiving your payment,depends on pumps.

4. Q: where is your loading port?

        A: Ningbo, China port

5. Q: Are you a manufacturer or trading company

        A: We are a manufacturer specialize in water pump and other pumps more than 20 years.

For more information, please contact me.

Detailed Images








Q: Why does the centrifugal pump close the pressure to start?
Therefore, the operation rules of multistage centrifugal pumps require that the inlet valve be opened before opening, and the outlet valve is closed. However, the export valve closed time can not be too long, because at this time the medium in the pump cycle, the medium temperature gradually increased, easy to cause mechanical seals, due to lack of lubrication friction and wear or damage.
Q: How much water does the water ring vacuum pump run for an hour? If there is no steam separator, does the water vaporize?
Water ring vacuum pump is divided into many types, different sizes, different types, so water is different. As for how much water the no fixed amount, but to ensure that the water temperature is in 25 degrees, not more than 35 degrees can be.
Q: What are the characteristics of a pipe shield pump?
According to the transmission of liquid temperature, pressure, viscosity and particle level have different requirements, the pump can be divided into the following types: first, the basic type (standard type) transport medium temperature does not exceed 120 degrees, the head of not more than 100m, the pump other types are variations on the basic type and improved.
Q: Is the diaphragm pump and the drain pump one?
Therefore, the need to play a liquid discharge pump, if the medium is corrosive liquid, high viscosity, volatile, flammable, highly toxic liquid, you can choose diaphragm pump. Conversely, the general liquid, there is no special requirements, you can use the general centrifugal pump to reduce costs.
Q: What does "anti pump" mean in pump operation?
Function: anti pump effect when used for pumping concrete pumping occurs overpressure, the pumping pressure is above 25MPA, the concrete conveying pipe out of ash, can be understood as the precursor of pipe blockage, at this time should immediately use the anti pump, the concrete from the conveying pipe in the suction into the hopper, thus preventing plugging happen
Q: What is the principle of a turbopump?
A machine that converts the energy contained in a fluid medium into mechanical work [turbine]. Also known as turbines, turbines. Turbine is the transliteration of English turbine, derived from the Latin word "turbo", meaning "rotating object". The working conditions of turbines are different from those of the employed ones, so their structure types are various, but the basic working principle is similar. The most important component of a turbine is a rotating element (rotor or impeller) that is mounted on a turbine shaft and has blades uniformly arranged along the circumference. The energy of the fluid is converted into kinetic energy in the flow through the nozzle, and when the fluid passes through the rotor, the fluid impacts the blade and drives the rotor to rotate, thus driving the turbine shaft to rotate. The turbine shaft drives the other machinery directly or through the transmission mechanism, and outputs mechanical work. According to the turbine working fluid used can be divided into different turbine (used as a power source of Hydropower Station) and steam turbine (used in thermal power plant, ship propulsion), gas turbine (used as jet propulsion, ship power, and power plants, with a small peak load power station and air turbine (only) as a small power).
Q: What is the "variable" of a variable pump? Is the displacement change or the flow change? Thank you
Variable pump variable refers to the flow can be changed to distinguish from the constant flow of quantitative pumps.
Q: What are the problems that should be paid attention to when using vacuum pumps?
(1) check the vacuum pump line and the joint site regularly to see if there is any looseness. Turn the vacuum pump by hand and see if the vacuum pump is flexible.(2) add lubricating oil to the bearing body, observe the oil level at the center line of the oil mark, and the lubricant shall be replaced or supplemented in time.(3) plug screw vacuum pump of the water screw, filling water (or lead paste). (4) turn off the gate valve of the water outlet pipe and the outlet pressure gauge and the vacuum gauge. (5) point motor, and see if motor steering is correct.(6) start the motor. When the vacuum pump is in normal operation, open the outlet pressure gauge and the inlet vacuum pump. As soon as the proper pressure is shown, the gate valve is gradually opened, and the motor load is checked.
Q: Because the water pressure of the booster pump is not enough, it can not work automatically. It can only be operated by hand. It is inconvenient to use.
One possibility is the automatic type household booster pump used for a period of time, automatic failure phenomenon, it is mainly stainless steel and other metal products in pipes, long-term precipitation to shut off the power supply after unloading, unscrew the top screw, remove the plastic sheet to be cleaned, and then, according to the original reset, the normal debugging. Can be re used. But that's not why if your booster pump isn't working properly all the time.
Q: What is the distance between the pump and the wall?
What do you mean by that? If your pump is parallel to the wall! Then, the wall of the pump near the wall is usually 500mm. This is an empirical data, considering the import pipe length, pump maintenance and motor heat dissipation and other aspects of the situation to determine. Dozens of pumps installed in our company are placed in this size! Hope to be of help to you.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords