• SJW-WB Micro-controlled Compensation Voltage Stabilizer with Non-contact System 1
SJW-WB Micro-controlled Compensation Voltage Stabilizer with Non-contact

SJW-WB Micro-controlled Compensation Voltage Stabilizer with Non-contact

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Piece pc
Supply Capability:
5000 Pieces per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Feature

 

Integrating the advance duplex winding compensation mode¡¢non-contact Switch and microcomputer controlled regulating technology. It has the features of high efficiency and energy-saving¡¢fast adjustment¡¢three phase automatic balanced no mechanical malfunction or carbon brush wearing, also with the functions of delay¡¢under/over voltage alarm and protection.

  • Adopting the advanced duplex winding compensation technology which ensure little waveform distortion.

  • Adopting one-chip computer to control the thyristor and shifting combination for timing compensation adjustment enable it to realize the fast non-contact  adjustment. Strong instantaneous overload capacity makes it available with various loads

  • Adopting one-chip computer split-phase control, it has the functions of delay starting-up, three-phase automatic balance adjustment, display¡¢alarm and protection of open-phase, overrun and malfunction etc.

 

Main Technical Data

Phase No.: Three-phase four wire system 

Input voltage: 

*Phase voltage: 220V±20%(176~264V)

*Line voltage: 380V±20%(304~456V) 

Output voltage:

*Phase voltage: 220V±2.5%

*Line voltage: 380V±2.5%

Efficiency: > 95%

Response time: 0.2~0.5s optional             

Waveform distortion: ≤2%

Frequency: 50Hz/60Hz

Load power factor: >|±7|

Instant overloading capacity: 1.5-2 times of the rated current

Ambient temperature: -15°C ~+40°C

 

Application

Broadcast & Television system, Microwave telecommunication Unattended station,Industrial control system, Computer system, Industrial equipment upporting, Elevator supporting etc. occasion that requires regulated power source.

Q: Who knows how big transformers and lines the 36V transformer uses in lighting?
Depending on your load capacity, primary voltage, site reservation, etc.. For example, 3.6KW lighting, with 4KVA transformers, the primary side 380V with 2.5 square (copper wire) enough, two times the side of 25 square.
Q: Why should lighting transformers be used in factories and mines?
There are two cases. One is the general factories and mines, and the low voltage is three-phase four wire system, and the neutral point is directly grounded. Between the phase line and the zero line is 220V, which can be connected with the illumination load.
Q: 1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
First of all, make sure your power is too large, but you are not recommended to do so, the cost is too high, the pressure drop is too large, you can raise the voltage to 220V or higher, and then transfer to avoid power losses. If the direct transmission, the power is slightly larger, the line will be very rough, the cost will be very high
Q: The difference between lighting transformers and control transformers
The lighting voltage is 36 and 12V, the signal lamp is 6V, the control winding is 127, 110V, the one or two insulation, and the two one is grounded.Simple lighting transformers, the two voltage is not so diverse.
Q: How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
General digital multimeter has a capacitor (some of the files with a million capacitance test table of Jack, some use pen)
Q: Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
Line lights, lighting transformers in general how many low voltage, can live operation, but to do safety measures. For example, do not short-circuit, damp environment, wear insulation shoes, wearing insulating gloves and so on.In fact, all the voltage levels, as long as safety measures can be done live operation.
Q: How many A leakage protection switches are used in 5000VA lighting transformers?
It is widely used in the electronic industry or industrial and mining enterprises, in the machine tool and the mechanical equipment, the control power of the general electric circuit, the use of the power supply of the safety lighting indicator lamp.
Q: Power and lighting transformers, lighting quality will be affected much?
The quality of transformer itself, coupling coefficient, overload capacity, as well as the impact current of the bulb, the cold resistance of the filament and the starting factor at the same time, it is better to choose the 400VA transformer.
Q: Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
Pe=19.5KW, installed capacityKx=1 coefficient of demandPjs=KxPe=19.5KW, calculated loadCOS, phi, =0.85, power factorIjs=KxPe/3/220/cos phi (Ijs calculates current, voltage, 380V/220V, three-phase)=1*19.5*1000/3/220/0.85=34.76A
Q: How to calculate the rated capacity of small transformers for lighting purposes?
In view of the power [kVA] conversion of each load, multiplied by the amount of consumption, according to the importance of the load, equipment location, voltage statistics, set the load line and load place of plastic case transformer capacity and its connection position. The future load power equipment shall be judged on the basis of prior installation or consideration of the economy in terms of equipment addition, installation, etc..
Our leading products have obtained Telecom Equipment Network Access License of China Information Industry Department. All our products are qualified and have passed the country surveillance bureau examination. And we believe that we can be your faithful friends and reliable partner forever.

1. Manufacturer Overview

Location Zhejiang,China (Mainland)
Year Established 2000
Annual Output Value US$10 Million - US$50 Million
Main Markets South America; Eastern Europe; Southeast Asia; Africa; Mid East; Eastern Asia; Western Europe
Company Certifications ISO9001 Certificate

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port
Export Percentage 51% - 60%
No.of Employees in Trade Department 3-5 People
Language Spoken:
b) Factory Information
Factory Size: 5,000-10,000 square meters
No. of Production Lines
Contract Manufacturing OEM Service Offered
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords