Gigabit Power Over Ethernet Splitter JTP-04G
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 Pieces pc
- Supply Capability:
- 1000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
High lights
Support IEEE802.3af or IE802.3at
Power Detectioand Classification
port LAinput (power+ data)
port LAoutput ( Data) + power connecting
Support 12V or 24V power output
Key Features
Complies with IEEE802.3 10Base-T; IEEE802.3u 100Base-TX; IEEE802.3ab 1000Base-T
Complies with IEEE 802.3 at PoE+ and IEEE802.3af PoE Standards
Supports two 10M/100M auto-detect Half/Full duplex switch ports with TX interfaces.
Two Port RJ-45 interfaces, One Data+Power input ; One Data output and Power connecting
share power over RJ-45 Ethernet cable to devices; support power and Ethernet functioto non-PoE device
Auto-detect PoE equipment, IEEE802.3at or IEEE802.3af , protecting the device from being damaged by incorrect link
Support 12V 2A and 24V 1.25A PoE power output voltage,
Palm size case
Power saving design, keep less power over RJ45 cable until PD device request
LED indicators for Power functioenable
- Q: What transformer can be used in a safety voltage lighting transformer?
- 220V/36V or 24V isolation transformer. Double winding, high and low voltage coils, not connected.
- Q: How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
- Voltage x current = power, in general we are using the total power of 2/3, you can press this type of calculation, if the installation of electrodeless lights, the line should be separated,
- Q: What type of low voltage transformer should be adopted for safety lighting power supply?
- We have produced many low voltage lighting transformers, such as outdoor waterproof, high-power stage lighting, as well as indoor small power transformers, customer response, but also good! For example, Guangzhou Color Art Lighting Co., Ltd., before them, our reputation is good!
- Q: Why should lighting transformers be used in factories and mines?
- In some factories and mines (such as power plants), in order to supply power reliability, the power system is grounded in a three-phase, ungrounded, or neutral manner. In this way, the transformer must be connected to a neutral grounding type with a special transformer to supply power to the lighting.
- Q: Is the substation separate from the power and illumination transformer?
- The power and lighting power supply in the substation need not be separated. In a large capacity power plant, the lighting can be electrically powered to ensure that the generator is stopped. The lighting source is often separated from the lighting transformer and powered by other power supplies.
- Q: 3 24V100W lights, I need to use a large capacity transformer (220V change 24V)?
- The quality of transformer itself, coupling coefficient, overload capacity, as well as the impact current of the bulb, filament, cold resistance and simultaneous startup factor, it is better to choose the 400VA transformer
- Q: How is the lighting power of the 380V transformer calculated?
- Special transformer power transformer (electric furnace transformer, rectifier transformer, power frequency test transformer, voltage regulator, transformer, audio, mine variable frequency transformers, high frequency transformer, transformer, instrument transformer, impact power transformer, reactor, mutual inductor etc.) circuit with T symbol number. For example: T01, T201 etc.
- Q: Power and lighting transformers, lighting quality will be affected much?
- The bulb adopts a luminous two stage tube combined lamp holder, and the calculation process is very complicated. The secondary voltage is different in different combinations. Because it is a direct current ignition, but also consider the efficiency of its rectifier, but the total power is unchanged.
- Q: Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
- Because of the brightness of the 36V safety voltage lamp brightness in the overhaul work is not enough, so now the well lighting design should not be 36V, and replaced by 220V, and only need to add a leakage protector on it.
- Q: Lighting, lights, transformers, bulb brightness is too low, what's the matter?
- Line light for safety light, voltage 24 volts and 36 volts, pay attention to the bulb and transformer voltage matching.
1. Manufacturer Overview
Location | Taiwan,Taiwan |
Year Established | 2003 |
Annual Output Value | US$1 Million - US$2.5 Million |
Main Markets | North America; South America; Eastern Europe; Southeast Asia; Africa; Oceania; Mid East; Eastern Asia; Western Europe; Northern Europe |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | 91% - 100% |
No.of Employees in Trade Department | |
Language Spoken: | |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range |
Send your message to us
Gigabit Power Over Ethernet Splitter JTP-04G
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 Pieces pc
- Supply Capability:
- 1000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches