Application:
T Series 1KVA~3KVA High frequency online UPS is specially designed for servers, data-center critical network devices, sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM and so on.
Key Features:
LED Indicators display Detailed Real-Time UPS Status and parameters.
Set Output Voltage, Frequency parameter and bypass function on the display.
Advanced MCU microprocessor control technology, ensure long life reliability.
Wide input voltage range, Zero transfer time
Excellent Protection against over voltage, over load, over current, over charge and so on.
Input L and N lines reverse wiring detection, Auto start when AC back.
DC start function, Input PFC revise function.
Humanization bypass output, can be adjustable.
Smart RS232 communication with monitoring software
Intelligent slot available for AS-400 Dry contact and SNMP card Remote control
Available to work with generators.
Lightning, surge, short circuit, Network/fax/modem surge protection
Basic tech datasheet
UPS Model | EX1K | T1K | EX2K | T2K | EX3K | T3K | |
Capacity | 1000VA/700W | 2000VA/1400W | 3000VA/2100W | ||||
Input | Voltage | (115~300) VAC | |||||
Frequency | 46~54Hz/56~64Hz (Adjustable via LCD panel) | ||||||
Output | Voltage | 220/230/240 (1±1%) VAC (Adjustable via LCD panel) | |||||
Frequency | 50/60Hz (Adjustable via LCD panel) 50Hz AC Mode: Follow AC Mode(AC Range 46~54Hz); Battery Mode:50Hz (1±0.2%) 60Hz AC Mode:Follow AC Mode(AC Range56~64Hz); Battery Mode: 60Hz(1±0.2%) | ||||||
Output Wave Form | Sine Wave | ||||||
Back-up Time | Full Load | ≥5′ | ≥9′ |
| ≥5′ |
| |
Half Load | ≥14′ | ≥21′ | ≥15′ | ||||
Battery Nominal DC Voltage | 36VDC | 96VDC | |||||
Transfer Time | 0ms | ||||||
Overload Capacity | 110%~150% maintain 30s then turn to bypass output, over 150% maintain 300ms | ||||||
Communications | RS-232+Intelligent Slot | ||||||
Environment | Temperature | 0C~40C | |||||
Humidity | 15%~90% | ||||||
Dimensions (W*D*H)mm | 400*145*220 | 460*192*348 | 460*392*348 |
- Q: How many power illuminator can 5Kva 36V transformer drive?
- Transformer (Transformer) is a device that uses the principle of electromagnetic induction to change AC voltage. The main components are primary coil, secondary coil and iron core (magnetic core). The main functions are voltage conversion, current conversion, impedance transformation, isolation, voltage stabilization (magnetic saturation transformer) and so on. According to use can be divided into: power transformers and special transformers (electric furnace transformer, rectifier transformer, power frequency test transformer, voltage regulator, mine, variable audio transformers, intermediate frequency transformers, high frequency transformer, transformer, instrument transformer, the impact of electronic transformer, reactor, transformer etc.). Circuit symbols are often used as the beginning of numbers. Examples: T01, T201, T, etc..
- Q: 1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
- First of all, make sure your power is too large, but you are not recommended to do so, the cost is too high, the pressure drop is too large, you can raise the voltage to 220V or higher, and then transfer to avoid power losses. If the direct transmission, the power is slightly larger, the line will be very rough, the cost will be very high
- Q: How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
- The number of tables in this table is increasing when the table rings to show 1.Method 2 is only to measure the capacitance is good or bad, can not be measured capacity.
- Q: Why is elevator lighting transformer installed?
- 9.4.5 well distribution shall comply with the following requirements:1 the elevator hoistway shall be dedicated to the elevator, and no equipment, cables and other devices related to the lift shall be installed in the hoistway.2 the well shall be provided with illumination, and the illumination shall not be less than 501x, and shall comply with the following requirements:
- Q: The transformer zero line has broken, has the result to the household illumination circuit?
- The power supply system in three-phase four line zero line is broken, the breakpoint of the single-phase circuit (220V) electrical burn by voltage to 380V. I met, the incandescent lamp suddenly particularly bright then the blow up of internal fuse TV has burned out. So in the three-phase four wire power supply system zero line asked to do repeat grounding in households is the reason.
- Q: Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
- Line lights, lighting transformers in general how many low voltage, can live operation, but to do safety measures. For example, do not short-circuit, damp environment, wear insulation shoes, wearing insulating gloves and so on.In fact, all the voltage levels, as long as safety measures can be done live operation.
- Q: How is the lighting power of the 380V transformer calculated?
- The transformer (Transformer) principle should change the AC voltage of the primary coil, the main component of the device level by using electromagnetic coil core (core) main functions: voltage transformation, current transformer, impedance converter, isolation, voltage regulator
- Q: Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
- So, safety regulations: lighting transformer must double winding type safety isolating transformer, prohibited the use of autotransformer.
- Q: Power and lighting transformers, lighting quality will be affected much?
- First look at this light. 24V100W, this specification is common in the headlights of large trucks, filled with inert gas, known as the small sun. Its power comes from a generator or battery, and is lit by alternating current or direct current.
- Q: How to calculate the rated capacity of small transformers for lighting purposes?
- Capacity of power transformer is the basic equipment for a total capacity of [kW] (maximum power consumption rate by a / X100 capacity) divided by the power load [%] value for benchmarking.
1. Manufacturer Overview
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Online UPS Power Supply 1KVA, 2KVA,3KVA
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 Units pc
- Supply Capability:
- 5000 Units per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords