EI Type Low Frequency Transformer
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 500 Pieces pc
- Supply Capability:
- 500000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Features
1. input:AC110V-250V 50-60Hz
2. Output:AC 3.0-800V
3. Modle:: EI series
4. CE,ROHS compliant, products are applying for CQC and ISO9001
Application:
Home electronic appliances, communication instruments, medical apparatus, power tools, message armchairs and air-condition.
Common Electrical Paramenters
Specification
1. machine- inserted silicon steel with fire relardation
2. Flame Retardant Nylon Bobbin3
3. equipment: 3 EI type transformer lines, 4 sets of vacuum annealing furnaces
Normal EI Pin Transformer Specifications
Item | Core type | Output power(w) | Item | Core type | Output power(w) |
EI28 | EI28/8×12 | 0.5-1 | EI57 | EI57/19×30 | 16-32 |
EI28 | EI28/8×16 | 0.7-1 | EI57 | EI57/19×38 | 20-40 |
EI35 | EI35/9.6×10 | 0.2-0.8 | EI66 | EI66/22×22 | 17-35 |
EI35 | EI35/9.6×12.5 | 0.25-1 | EI66 | EI66/22×28 | 24-45 |
EI35 | EI35/9.6×16 | 0.4-1.7 | EI66 | EI66/22×35 | 36-58 |
EI35 | EI35/9.6×20 | 0.6-2.5 | EI66 | EI66/22×45 | 55-77 |
EI41 | EI41/13×13 | 0.6-2.3 | EI76 | EI76.2/25.4×25 | 65-88 |
EI41 | EI41/13×16 | 1-3.6 | EI76 | EI76.2/25.4×31.5 | 71-95 |
EI41 | EI41/13×21 | 1.6-5.5 | EI76 | EI76.2/25.4×40 | 70-97 |
EI41 | EI41/13×26 | 2.3-7.7 | EI76 | EI76.2/25.4×50 | 86-123 |
EI48 | EI48/16×16 | 2-5 | EI85.8 | EI85.8/28.6×29 | 70-95 |
EI48 | EI48/16×20 | 2.8-7.2 | EI85.8 | EI85.8/28.6×36 | 84-120 |
EI48 | EI48/16×25 | 4.6-11.1 | EI85.8 | EI85.8/28.6×46 | 105-154 |
EI48 | EI48/16×32 | 7-10 | EI85.8 | EI85.8/28.6×58 | 130-200 |
EI54 | EI54/18×18 | 5-12 | EI96 | EI96/32×40 | 100-150 |
EI54 | EI54/18×22.5 | 8-17 | EI96 | EI96/32×45 | 110-160 |
EI54 | EI54/18×29 | 11-25 | EI105 | EI105/35 | 500-700 |
EI54 | EI54/18×36 | 17-34 | EI114 | EI114/38 | 700-1000 |
EI57 | EI57/19×19 | 7-16 | All the output voltage and current are according to customers requirements. | ||
EI57/19×24 | 14-21 |
- Q: What transformer can be used in a safety voltage lighting transformer?
- 220V/36V or 24V isolation transformer. Double winding, high and low voltage coils, not connected.
- Q: How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
- Connect 220V method, FireWire 220V terminal, zero line 0 terminal, 380V terminal is not connected.Connect 380V method, A phase 380V terminal, B phase 0 terminal, 220V terminal is not connected.
- Q: What type of low voltage transformer should be adopted for safety lighting power supply?
- Isolated transformer, once 380V or 220V, two voltage, 36V, 24V, 12V, several categories, do not allow the use of autotransformer.
- Q: Why should lighting transformers be used in factories and mines?
- In some factories and mines (such as power plants), in order to supply power reliability, the power system is grounded in a three-phase, ungrounded, or neutral manner. In this way, the transformer must be connected to a neutral grounding type with a special transformer to supply power to the lighting.
- Q: How many A leakage protection switches are used in 5000VA lighting transformers?
- AC circuit transformer for lighting lamp is suitable for 50-60Hz, is the power supply with safety shell low-voltage safety lights, can choose 220V or 380V power supply input voltage: 0V, 220V, 380V, 0V, 6.3V, output voltage: 12V, 24V, 36V.
- Q: Does the lighting work properly? Doesn't that power equipment start voltage unstable?
- It is not easy to control, the power and lighting and electricity; if the transformer capacity is small, and relatively large power equipment start frequently, voltage stability will be poor, the lamp brightness will fluctuate dramatically, have effect on visual acuity. But as long as the design is reasonable, it has little effect.
- Q: Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
- The self winding transformer is connected by all its windings, and depends on the position of the sliding contacts to change the magnitude of the voltage. Therefore, there is not only a magnetic connection between the primary winding of the autotransformer (the power circuit) and the two winding (the power supply circuit), but also the direct connection of the circuit. It forms a circuit with the earth, so it can not be used as the power source of the safety voltage
- Q: Power and lighting transformers, lighting quality will be affected much?
- The bulb adopts a luminous two stage tube combined lamp holder, and the calculation process is very complicated. The secondary voltage is different in different combinations. Because it is a direct current ignition, but also consider the efficiency of its rectifier, but the total power is unchanged.
- Q: Why can't autotransformer be used as transformer for safety lighting?
- The main and auxiliary coils of the autotransformer have common parts. Once the short-circuit is made, the lighting circuit is directly connected with the high voltage circuit, which is very dangerous
- Q: What's the function of the lighting transformer?
- Applies to some requirements for safe voltage 24V - 36V lighting sites. Such as: basement, tunnel, dangerous goods warehouse and so on. Then there is the (mobile, temporary) safety lighting for the overhaul.
1. Manufacturer Overview
Location | Tianjin,China |
Year Established | 2002 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | 18.00% North America 15.00% South America 13.00% Africa 13.00% Eastern Europe 5.00% South Asia 5.00% Central America 5.00% Western Europe 5.00% Eastern Asia 5.00% Mid East 5.00% Oceania 5.00% Southeast Asia 3.00% Southern Europe 3.00% Northern Europe |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Tianjin Port |
Export Percentage | 51% - 60% |
No.of Employees in Trade Department | 3-5 People |
Language Spoken: | English, Chinese |
b) Factory Information | |
Factory Size: | 1,000-3,000 square meters |
No. of Production Lines | 5 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Low and/or Average |
Send your message to us
EI Type Low Frequency Transformer
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 500 Pieces pc
- Supply Capability:
- 500000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords