• Switch Mode Power Supply 12V 250 Watt for LEDs System 1
Switch Mode Power Supply 12V 250 Watt for LEDs

Switch Mode Power Supply 12V 250 Watt for LEDs

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
10 Pieces pc
Supply Capability:
10,000 Pieces per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

Specification:

 

Model

HS-250-12

HS-250-15

HS-250-24

HS-250-27

HS-250-48

Specification

 

 

 

 

 

DC output voltage

12V

15V

24V

27V

48V

Output voltage tolerance(Note:2)

±1%

±1%

±1%

±1%

±1%

Rated output current

20A

16A

10A

9A

5.2A

Output current rage

0-20A

0-16A

0-10A

0-9A

0-5.2A

Wave and noise(Note :3)

150mVp-p

150mVp-p

150mVp-p

150mVp-p

200mVp-p

Inlet stability(Note :4)

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load stablity (Note :5)

±1%

±1%

±0.5%

±0.5%

±0.5%

Efficiency

79%

80%

82%

82%

84%

AC input voltage range

90~132VAC/180-264VAC selected by switch 47-63Hz;254-370VDC

Input current

5.0A/115V 2.5A/230V

AC INrush current

25A/115V 50A/230V

Leakage current

<3.5mA/240VAC

Overload protection

105%~135% hiccup mode, auto recovery

Over voltage protection

115%-135% cut off the output, auto recovery

High-temperature protection

Rectifier >= 90°C cut off the output, auto recovery

Temperature coefficient

±0.03%/°C(0~50%)

Setup rise hold up time

200ms,100ms,20ms

Vibration

10~500Hz,2G 10min,/1cycle,Period for 60min,each axes

Withstand voltage

Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC

Isolation resistance

Input and output internal:Input and enclosure,Output and enclosure:500VDC/100MΩ

Working temperature and humidity

-10°C~+60°C(Refer to output derating curve),20%~90%RH

Store temperature and humidity

-20°C~+85°C,10%~95%RH

Overall dimension

199×98×50mm

Weight/Packing

0.7Kgs, 24pcs/CTN

Note:

 

1.The testing condition for the parameter above is :230VAC input,rated load,25°C70% RH.Humidity.

2.Tolerance include the setting tolerance,line stability and load stability.(Note:5).

3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.

4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.

5.Load stability test:the load is from 0% to 100%.  

 

 

Q: What transformer can be used in a safety voltage lighting transformer?
220V/36V or 24V isolation transformer. Double winding, high and low voltage coils, not connected.
Q: Who knows how big transformers and lines the 36V transformer uses in lighting?
Depending on your load capacity, primary voltage, site reservation, etc.. For example, 3.6KW lighting, with 4KVA transformers, the primary side 380V with 2.5 square (copper wire) enough, two times the side of 25 square.
Q: What type of low voltage transformer should be adopted for safety lighting power supply?
Isolated transformer, once 380V or 220V, two voltage, 36V, 24V, 12V, several categories, do not allow the use of autotransformer.
Q: Why should lighting transformers be used in factories and mines?
In some factories and mines (such as power plants), in order to supply power reliability, the power system is grounded in a three-phase, ungrounded, or neutral manner. In this way, the transformer must be connected to a neutral grounding type with a special transformer to supply power to the lighting.
Q: Why is the two side of the lighting transformer grounded?
Today's lighting products, regardless of the control system or the electronic power system itself, contain many semiconductorsComponents such as rectifier diodes, transistors, integrated circuits, LED, and so on. Semiconductor components are susceptible to staticElectrical damage, the two side of the power transformer grounding, help to produce a variety of factors, high pressure, residual static electricityDrain to avoid static electricity on the main circuit, to ensure product life.
Q: Is the substation separate from the power and illumination transformer?
The power and illumination of the substation are all used on a transformer, which is separated by power and lighting by the station screen of this transformer.
Q: How many A leakage protection switches are used in 5000VA lighting transformers?
AC circuit transformer for lighting lamp is suitable for 50-60Hz, is the power supply with safety shell low-voltage safety lights, can choose 220V or 380V power supply input voltage: 0V, 220V, 380V, 0V, 6.3V, output voltage: 12V, 24V, 36V.
Q: Can the 500 volt lighting transformer be changed into an electric welder?
500 VA transformer should not be used as an electric welding machine, so it is very difficult to reform the system, so it is better to buy a new electric welder
Q: What's the function of the lighting transformer?
Illumination transformer: usually refers to the secondary output voltage for the safety voltage 24V - 36V, only for special lighting power supply using voltage converter.
Q: Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
The previous elevator hoistway lighting required the 36V safety voltage, and you can see how many power lamps are required for the hoistway, and select the transformer
Our company carries out a strict management mechanism, and spares no effort to establish effective incentives and constrains system; improve corporate structure. Under no circumstance, the company always adheres to the business philosophy all matters, big or small; equal consultation; continuous improvement.

1. Manufacturer Overview

Location Shenzhen, Guangdong, China (Mainland)
Year Established 2011
Annual Output Value US$5 Million - US$10 Million
Main Markets North America; South America; Eastern Europe; Southeast Asia; Mid East; Western Europe; Central America; Northern Europe; South Asia
Company Certifications ROHS Test Report; Waterproof Power Supply CE-LVD; Waterproof Power Supply CE-EMC; CE-LVD

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Yantian
Export Percentage 41% - 50%
No.of Employees in Trade Department 3-5 People
Language Spoken: English, Chinese, Spanish, Japanese, Portuguese, German, French, Russian, Korean, Italian
b) Factory Information
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords