• Switch Mode Power Supply 12V 250 Watt for LEDs System 1
Switch Mode Power Supply 12V 250 Watt for LEDs

Switch Mode Power Supply 12V 250 Watt for LEDs

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
10 Pieces pc
Supply Capability:
10,000 Pieces per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

Specification:

 

Model

HS-250-12

HS-250-15

HS-250-24

HS-250-27

HS-250-48

Specification

 

 

 

 

 

DC output voltage

12V

15V

24V

27V

48V

Output voltage tolerance(Note:2)

±1%

±1%

±1%

±1%

±1%

Rated output current

20A

16A

10A

9A

5.2A

Output current rage

0-20A

0-16A

0-10A

0-9A

0-5.2A

Wave and noise(Note :3)

150mVp-p

150mVp-p

150mVp-p

150mVp-p

200mVp-p

Inlet stability(Note :4)

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load stablity (Note :5)

±1%

±1%

±0.5%

±0.5%

±0.5%

Efficiency

79%

80%

82%

82%

84%

AC input voltage range

90~132VAC/180-264VAC selected by switch 47-63Hz;254-370VDC

Input current

5.0A/115V 2.5A/230V

AC INrush current

25A/115V 50A/230V

Leakage current

<3.5mA/240VAC

Overload protection

105%~135% hiccup mode, auto recovery

Over voltage protection

115%-135% cut off the output, auto recovery

High-temperature protection

Rectifier >= 90°C cut off the output, auto recovery

Temperature coefficient

±0.03%/°C(0~50%)

Setup rise hold up time

200ms,100ms,20ms

Vibration

10~500Hz,2G 10min,/1cycle,Period for 60min,each axes

Withstand voltage

Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC

Isolation resistance

Input and output internal:Input and enclosure,Output and enclosure:500VDC/100MΩ

Working temperature and humidity

-10°C~+60°C(Refer to output derating curve),20%~90%RH

Store temperature and humidity

-20°C~+85°C,10%~95%RH

Overall dimension

199×98×50mm

Weight/Packing

0.7Kgs, 24pcs/CTN

Note:

 

1.The testing condition for the parameter above is :230VAC input,rated load,25°C70% RH.Humidity.

2.Tolerance include the setting tolerance,line stability and load stability.(Note:5).

3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.

4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.

5.Load stability test:the load is from 0% to 100%.  

 

 

Q: How many power illuminator can 5Kva 36V transformer drive?
Of course, if you want to bring more is not impossible, but depends on the working conditions, the actual power = nominal power, short time use (to ensure that the transformer temperature rise is not too high) is also available
Q: What transformer can be used in a safety voltage lighting transformer?
220V/36V or 24V isolation transformer. Double winding, high and low voltage coils, not connected.
Q: Why is the two side of the lighting transformer grounded?
The metal shell transformer grounding grounding protection is called: under normal circumstances is not charged, electrical metal and in the damaged insulation or other circumstances may be charged part (i.e. metal structure and insulation electrical parts part) and grounding wire connected to a reliable way to protect people.
Q: The difference between lighting transformers and control transformers
A control transformer is a low voltage appliance, usually used as a power supply or part of a lighting for the control of electrical equipment such as machine tools. There are usually two different voltage outputs,
Q: Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
What you think? Your light is 220V, right. Over 36V, it's better not to live with electricity unless there is good protection
Q: How many A leakage protection switches are used in 5000VA lighting transformers?
According to the working principle of the protector, it can be divided into three kinds: voltage type, current type and pulse type. The voltage protection device is connected to the transformer neutral point and the ground, when the electric shock when the neutral point voltage offset to the real estate, in order to make the action to protect the power off, but because it is the protection of the transformer low voltage network, cannot be classified protection, so the power range is large, frequent moves, so has been eliminated. The pulse current protector is a sudden change in the phase and amplitude of the three-phase unbalanced leakage current when an electric shock occurs, which is used as an action signal, but also a dead time. The current type current leakage protector is widely used, so the protector of current type is mainly introduced below.
Q: Does the lighting work properly? Doesn't that power equipment start voltage unstable?
As long as the capacity of the transformer is enough, the voltage fluctuation of the line will be sure to occur when the high power equipment is started. Such fluctuations do not have much impact on the lighting.
Q: Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
The self winding transformer is connected by all its windings, and depends on the position of the sliding contacts to change the magnitude of the voltage. Therefore, there is not only a magnetic connection between the primary winding of the autotransformer (the power circuit) and the two winding (the power supply circuit), but also the direct connection of the circuit. It forms a circuit with the earth, so it can not be used as the power source of the safety voltage
Q: Power and lighting transformers, lighting quality will be affected much?
Corresponding to the transformer power supply, in order to save costs and reduce costs, the choice of AC ignition method is better. Pure resistive load, the power factor is 1. The 3 *100W=300W is the capacity of the required transformer
Q: Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
Pe=19.5KW, installed capacityKx=1 coefficient of demandPjs=KxPe=19.5KW, calculated loadCOS, phi, =0.85, power factorIjs=KxPe/3/220/cos phi (Ijs calculates current, voltage, 380V/220V, three-phase)=1*19.5*1000/3/220/0.85=34.76A
Our company carries out a strict management mechanism, and spares no effort to establish effective incentives and constrains system; improve corporate structure. Under no circumstance, the company always adheres to the business philosophy all matters, big or small; equal consultation; continuous improvement.

1. Manufacturer Overview

Location Shenzhen, Guangdong, China (Mainland)
Year Established 2011
Annual Output Value US$5 Million - US$10 Million
Main Markets North America; South America; Eastern Europe; Southeast Asia; Mid East; Western Europe; Central America; Northern Europe; South Asia
Company Certifications ROHS Test Report; Waterproof Power Supply CE-LVD; Waterproof Power Supply CE-EMC; CE-LVD

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Yantian
Export Percentage 41% - 50%
No.of Employees in Trade Department 3-5 People
Language Spoken: English, Chinese, Spanish, Japanese, Portuguese, German, French, Russian, Korean, Italian
b) Factory Information
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords