Constant Current LED Driver 60 Watt 1.8A
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 10,000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specification:
a.60W 1.8A LED driver, constant voltage.
b. Epoxy encapsulated, IP67. Suitable for outdoor lighting application.
c. Automated protection for over load and over temperature
d. Aluminum housing, good for heat dissipation
e. Cooling by free air convection.
f. Application: LED spotlight, LED downlight, LED panel light
Model | GLS-60-1800 | |
Voltage | 170-250V AC/90-130V AC | |
Frequency | 47-63 Hz | |
AC Current | 0.7A max@220V | |
Efficiency | 80% | |
DC Output | Voltage | 24V-36V |
Current | 1800mA | |
Rated Power | 60W | |
Protection | Over Load | 20% exceed in short time is allowed |
Short Circuit | Auto recovery | |
Over Voltaqge | ≤280V | |
Over Temperature | ≤85°C | |
Others | Store Temperature | - 40--85°C |
Wokring Temperature | - 25--55°C | |
Dimension/Weight | 180*69*43MM / 890g (Aluminium Housing) | |
Packing/Carton Size | 16PC/CTN 455×265×210mm | |
Input Cable | VDE H03VV-F 3G×0.75mm2 (330mm) | |
Output Cable | VDE H03VV-F 2×0.75mm2 (330mmx2) | |
Certificate | CE | Compliant to EN 60950-1:2006;
EN61000-6-3:2001; EN 55022:2006+A1:2007; EN61000-4-2/-3; EN61000-6-1:2001; EN55024:1998+A1:2000+A2:2003
|
RoHs | Free from lead, Cadmium, Mercury, Hexavalent
Chromium and/or PBB &PBDE
|
- Q:The difference between lighting transformers and control transformers
- The lighting voltage is 36 and 12V, the signal lamp is 6V, the control winding is 127, 110V, the one or two insulation, and the two one is grounded.Simple lighting transformers, the two voltage is not so diverse.
- Q:How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
- The number of tables in this table is increasing when the table rings to show 1.Method 2 is only to measure the capacitance is good or bad, can not be measured capacity.
- Q:The transformer zero line has broken, has the result to the household illumination circuit?
- No, the zero line of the transformer doesn't go through the zero line of the transformer. It is a star connection, and the center point is zero line
- Q:Is the substation separate from the power and illumination transformer?
- The power and lighting power supply in the substation need not be separated. In a large capacity power plant, the lighting can be electrically powered to ensure that the generator is stopped. The lighting source is often separated from the lighting transformer and powered by other power supplies.
- Q:Lighting, lights, transformers, bulb brightness is too low, what's the matter?
- Generally, the power of the transformer is the apparent power, and the light bulb is the active power, and the power matching is taken into account.
- Q:Why should lighting transformers be used in factories and mines?
- There are two cases. One is the general factories and mines, and the low voltage is three-phase four wire system, and the neutral point is directly grounded. Between the phase line and the zero line is 220V, which can be connected with the illumination load.
- Q:What transformer can be used in a safety voltage lighting transformer?
- An isolated transformer is a transformer that is electrically isolated from an input winding and an output winding. The isolated transformer is used to avoid accidental touching of the charged body at the same time, and the isolation of the transformer is to isolate the current of the former side winding coil.
- Q:What's the function of the lighting transformer?
- Illumination transformer: usually refers to the secondary output voltage for the safety voltage 24V - 36V, only for special lighting power supply using voltage converter.
- Q:How to calculate the rated capacity of small transformers for lighting purposes?
- If the flow of large capacity motor starting current and welding machine, large current flows in a short period of time in the load even when the power equipment capacity can withstand current flow in a short time, but due to a voltage drop excitation electromagnetic switch relief, the motor can not start, damaged or the undesirable phenomenon of welding. Therefore, the voltage drop rate should be calculated as less than 10% of the supply voltage, as calculated below.
- Q:1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
- First of all, make sure your power is too large, but you are not recommended to do so, the cost is too high, the pressure drop is too large, you can raise the voltage to 220V or higher, and then transfer to avoid power losses. If the direct transmission, the power is slightly larger, the line will be very rough, the cost will be very high
1. Manufacturer Overview |
|
---|---|
Location | Shenzhen, Guangdong, China (Mainland) |
Year Established | 2011 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | North America; South America; Eastern Europe; Southeast Asia; Mid East; Western Europe; Central America; Northern Europe; South Asia |
Company Certifications | ROHS Test Report; Waterproof Power Supply CE-LVD; Waterproof Power Supply CE-EMC; CE-LVD |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | Yantian |
Export Percentage | 41% - 50% |
No.of Employees in Trade Department | 3-5 People |
Language Spoken: | English, Chinese, Spanish, Japanese, Portuguese, German, French, Russian, Korean, Italian |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Constant Current LED Driver 60 Watt 1.8A
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 10,000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords