1.Structure of Single Stage Double Suction End Suction Pump for Air ConditionerDescription
End Suction Centrifugal Pump complies fully to the European Standard BS EN733 / DIN24255 of performance and dimensions. They are used for pumping clean water or liquids similar to water, achieving wide application on plants, mines, city water supplies, air-conditioning coolers, firefighting system and irrigation. Pumps of the same model have different performance levels basing on different diameter after impeller trimming. Overall the whole series, there are only four sizes of shaft and five of bearing housing. As long as their bearing housings are of the same size, different pumps can interchange chief parts such as shaft, shaft sleeve, shaft seal, impeller nut, etc.
End Suction Centrifugal Pump is also very easy to be installed and maintained. Back pull-out design, driven through flexible coupling, so that pump casing and motor can remain in position while other spare parts are removed.
2.Main Features of Single Stage Double Suction End Suction Pump for Air Conditioner
• very easy to be installed and maintained
•Back pull-out design
•Driven through flexible coupling
•Customized design is available, OEM and ODM are welcomed.
•Horizontally and vertically installation as different pipeline system
3.Single Stage Double Suction End Suction Pump for Air Conditioner Specification
Material | Cast iron |
Pump diameter | 350-1600mm |
Flow range | 1~200L/s |
Pressure range | 0.2~2.25MPa |
Motor power range | 1.5~200kW |
Inlet/outlet Diameter | DN50~DN200mm |
Casing | Cast Iron Standard, Ductile Iron, Stainless Steel Optional |
Impeller | Bronze Standard ,Cast Iron, Stainless Steel Optional |
Shaft | ASTM420Standard,ASTM304,ASTM316,ASTM1045 Optional |
Shaft Seal | Mechnical Seal, Gland Pakcing Optional |
Flow rate | 2-1100m3/h |
Head | 2-152m |
Speed | 1450 or 2900(50hz),1750 or 3500(60hz) |
Working Pressure | 1.6PMa or 2.0PMa |
4.Picture of Single Stage Double Suction End Suction Pump for Air Conditioner
5.FAQ
① What is your product range?
Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage
pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe
water pump, boiler water pump, etc.
② Are you a manufacturer?
Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.
③ What information should I let you know if I want to get a quotation?
Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also provide the pump model you are using now, price will be calculated as per the pump model, if not, we will recommend relevant product for reference.
- Q: What is a water pump coupling device?
- The water pump coupling device comprises a coupler, a coupling flange, a guide rod and an upper fixing plate, wherein the contact surface of the coupling base and the coupling slide plate is provided with an annular groove, and a soft sealing gasket is tightly fixed on the groove. By adopting the structure, the coupling contact surface of the coupling slide plate and the coupling base is sealed firmly by an annular sealing groove
- Q: How does the centrifugal pump pump and cut the pump?
- Check the motor, pump and fasteners in good condition; whether the lubricant is added or not;Disc dynamic coupling, whether or not stuck phenomenon;Open the inlet valve, remove the gas in the pump or pump the gas out of the pump;
- Q: Double floor sewage pump circuit diagram of a small problem
- Q 2, SA and SS are select switches, and different positions indicate the same difference between the two nodes. SA hits the left position 13, 14 to connect, hits to the right position 21, 22 to connect. SS hit the middle position, 5 and 6 turn on, 7 and 8 turn on; hit the right position; 1 and 2 turn on; 11 and 12 turn on; hit the left seat; 9 and 10 turn on; 3, 4 turn on.
- Q: How to install, operate and maintain the pipeline booster pump?
- Should be "People's Republic of China network security law" requirements, since June 1, 2017, the use of Internet services to carry out real name authentication account. In order to ensure your Baidu account can be used normally, please check the account number as soon as possible. Thank you for your understanding and support.How to install, operate and maintain the pipeline booster pump?Brother Yao s Gc76 2547 | browseRecommended for 2016-12-01 23:52:54 best answerThe installation of booster pump must be installed horizontally or vertically according to the installation method. The direction of flow shall be consistent with the arrow on the pump body, and installed as far away from the water level as possible. A valve shall be installed on the pump inlet line for ease of use and maintenance. When the impeller is the aspiration level below the pump on the pump shaft end or around the pump should be installed check valve, the outlet is connected with 13 links for water use, at first use to pump should be filled with water, and tighten the screw plug. The pipe connection should be tight, especially the water inlet pipe can not leak, otherwise it will reduce the pump head or not pumping water. The pump cavity is not water, not a long time running, so as not to damage the seal
- Q: What is the displacement of the pump? Flow? What is the volume efficiency and mechanical efficiency of the pump?
- Mechanical efficiency: the ratio of theoretical torque to actual torque of the pump.
- Q: I want to know the concrete under 60 type pump performance, it is mainly the pump long spiral bored piles, such as the diameter of the pump, transportation distance, pumping height and so on, thank you!
- Maximum theoretical vertical transfer distance is m 270Maximum theoretical level conveying distance m 1200Distributing valve form S pipe valve (whole casting)
- Q: Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
- The direct connected pump impeller is directly mounted on the motor shaft, and the non direct connected pump and motor are two shafts, and the two shafts transmit torque through the coupling
- Q: Pneumatic diaphragm pump compressed air pressure is 4 kg, the discharge pressure is how big?
- Generally slightly lower than 0.4MPa, Zai 0.35Mpa or so, if the outlet is blocked, the outlet pressure will equal 0.4MPa
- Q: What are the parts of a pump? How do you classify it?I just want to know
- According to the working principle can be divided into: centrifugal type and volume type centrifugal pump. By the centrifugal force of the impeller will accelerate the refrigerant, through to stay, so as to achieve the purpose of boosting; volume by changing the refrigerant in the flow volume to boost purpose.According to the media and installation conditions, water pump: centrifugal pump used: the impeller pump shaft, a curved blade on the impeller impeller outlet. The central entrance water vertically along the tangential direction of axial flow pump: high speed, large flow, low lift, mixed flow pump and centrifugal pump structure similar to that of the blade outlet angle is different, wide flow channel, close to the performance of axial flow pump displacement pump: safety valve must be opened before the start (metering pump, screw pump)
- Q: What are the characteristics of the piston pump?
- 1 、 built in overvoltage protection and flow correction system.6 、 large screen LCD display.7. The well designed exhaust device can effectively remove the bubbles in the liquid.8, flow and pressure settings can be memory, and PLC communication (custom).
Send your message to us
Single Stage Double Suction End Suction Pump for Air Conditioner
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 10000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords