• Single Stage Double Suction End Suction Pump for Air Conditioner System 1
  • Single Stage Double Suction End Suction Pump for Air Conditioner System 2
  • Single Stage Double Suction End Suction Pump for Air Conditioner System 3
Single Stage Double Suction End Suction Pump for Air Conditioner

Single Stage Double Suction End Suction Pump for Air Conditioner

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

End Suction Centrifugal Pump

1.Structure of Single Stage Double Suction End Suction Pump for Air ConditionerDescription

End Suction Centrifugal Pump complies fully to the European Standard BS EN733 / DIN24255 of performance and dimensions. They are used for pumping clean water or liquids similar to water, achieving wide application on plants, mines, city water supplies, air-conditioning coolers, firefighting system and irrigation. Pumps of the same model have different performance levels basing on different diameter after impeller trimming. Overall the whole series, there are only four sizes of shaft and five of bearing housing. As long as their bearing housings are of the same size, different pumps can interchange chief parts such as shaft, shaft sleeve, shaft seal, impeller nut, etc.

End Suction Centrifugal Pump is also very easy to be installed and maintained. Back pull-out design, driven through flexible coupling, so that pump casing and motor can remain in position while other spare parts are removed.

2.Main Features of Single Stage Double Suction End Suction Pump for Air Conditioner

very easy to be installed and maintained

Back pull-out design

•Driven through flexible coupling

•Customized design is available, OEM and ODM are welcomed.

•Horizontally and vertically installation as different pipeline system

3.Single Stage Double Suction End Suction Pump for Air Conditioner Specification

 

Material

Cast iron

Pump diameter

350-1600mm

Flow range

1~200L/s

Pressure range

0.2~2.25MPa

Motor power range

1.5~200kW

Inlet/outlet Diameter

DN50~DN200mm

 

Casing

Cast Iron Standard, Ductile Iron, Stainless Steel Optional

Impeller

Bronze Standard ,Cast Iron, Stainless Steel Optional

Shaft

ASTM420Standard,ASTM304,ASTM316,ASTM1045 Optional

Shaft Seal

Mechnical Seal, Gland Pakcing Optional

 

Flow rate

2-1100m3/h

Head

2-152m

Speed

1450 or 2900(50hz),1750 or 3500(60hz)

Working Pressure

1.6PMa or 2.0PMa

 

4.Picture of Single Stage Double Suction End Suction Pump for Air Conditioner

 Single Stage Double Suction End Suction Pump for Air Conditioner

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also provide the pump model you are using now, price will be calculated as per the pump model, if not, we will recommend relevant product for reference.

 

 

 

 

Q: Rotary vacuum pump does not meet the requirements of vacuum, what are the reasons?
(1) the disk, stator or bushing is worn and shall be inspected, trimmed or replaced with a rotary vane vacuum pump.(2) the pump temperature is too high, which not only reduces the viscosity of the oil, increases the saturated vapor pressure, but also may cause cracking of the pump oil. Ventilation, cooling and environmental temperature should be improved. If the exhaust gas temperature is too high, should be cooled before entering the pump, the environment temperature is high, should try to use a better high speed vacuum pump oil or 3# diffusion pump oil. (10) because of the deformation, wear or movement of the parts, the maximum opening height of the check head can be reduced or even unable to be opened, the intake of oil is too little, and the vacuum degree of the rotary vane vacuum pump is reduced, and should be adjusted as shown in the assembly section. Open high, more oil, but open too high, check valve in some places on the stop, it will not automatically drop, lost to prevent oil returns. The commonly used rotary vane vacuum pumps mainly include double stage rotary vane vacuum pump and single-stage rotary vane vacuum pump
Q: What are the advantages and disadvantages of the pump control system and valve control system in the hydraulic system? How to choose in the project?
Valve control system is generally used for open systems, through the proportional valve or servo valve flow changes to control the motor or cylinder actuator action. The advantages of the system are energy saving, heat generation, and control accuracy. The disadvantage is that the system is complex and the cost is higher.
Q: What does "anti pump" mean in pump operation?
The working process of the main oil cylinder pushing back and forth against the pump when the S valve (C valve or valve or gate valve skirt) reverse swing, so the piston suction concrete cylinder is in the ash conveying pipe is exactly opposite is the pump suction pump (hopper is concrete and push into the hopper, the desizing)
Q: What is the lift of diaphragm pump?
Diaphragm pump lift is different from the centrifugal pump, refers to the diaphragm pump can raise the height of water, the unit is meters water column. Lift depends on the size of the outlet pressure, the pressure per kilogram is equivalent to 10 meters height
Q: What is the main difference between SK water ring vacuum pump and 2BV water ring vacuum pump?
The 2BV vacuum pump belongs to the machine pump coaxial type direct connection design. It saves space and is easy to install;The use of mechanical seals as standard configuration eliminates leakage and easy maintenance;Smooth running, low noise to 62 decibels;
Q: What should be used to pay attention to the use of mechanical pumps?
There are many kinds of pumps, such as centrifugal pumps, piston pumps, diaphragm pumps, vane pumps, gear pumps, etc.
Q: What are the conditions required for hydraulic pumps to complete oil absorption and compression?
Volume conditions: oil absorption cavity from small to large, complete oil absorption, oil pressure chamber has become smaller, complete pressure oil.Sealing conditions: the hydraulic pump itself should have good sealing
Q: Do you have a suction pump higher than 9 meters?
Pump rated suction generally 7 meters or so, it is estimated that no one calibration pump suction stroke 9 meters. Calibration suction range of 9 meters is not reliable.
Q: What do you mean by the self coupling device on the pump?
Overview of GAK self coupling device:The utility model relates to a GAK self coupling device, which is an automatic butt joint between a water outlet flange of a submersible electric pump and a water outlet pipe system.In the above additional coupling flange and the water outlet pipe seat inlet flange with a pair of wedge card, under the additional coupling flange and the water outlet pipe seat inlet flange and a pair of wedge cards in a wedge seat below the outlet pipe inlet flange card is made of elastic steel plate is fixed on the lower side of the seat pipe inlet flange. When the submersible pump water falling from above, Kaxianka additional coupling flange at the top of the wedge wedge and seat card outlet pipe above the inlet flange together, in the role of the dignity of the pump and submersible inclined wedge clamp, two flange will be put together in a pair of wedge under additional coupling flange and the water outlet pipe seat inlet flange the card will be in the elastic plate under the action of automatic card together. The utility model can solve the problem that a large amount of water leakage between the two flanges of the coupling is saved when the automatic installation and disassembly of the electric submersible pump is convenient, thereby saving energy.
Q: What is the difference between an air pump and a water pump?
Pump performance of technical parameters are flow, suction, lift, shaft power, water power, efficiency, etc.; according to the different principles of work can be divided into volume pumps, vane pumps and other types. Displacement pump is to use its studio volume changes to transfer energy; vane pump is to use the rotating blade and water interaction to transfer energy, there are centrifugal pumps, axial flow pumps and mixed flow pumps and other types.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords