• Multistage Centrifugal Water Pump for Portable Water System 1
  • Multistage Centrifugal Water Pump for Portable Water System 2
  • Multistage Centrifugal Water Pump for Portable Water System 3
Multistage Centrifugal Water Pump for Portable Water

Multistage Centrifugal Water Pump for Portable Water

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

                      Multistage Centrifugal Water Pump for Portable Water

1.Structure of Multistage Centrifugal Water Pump for Portable Water Description

The high presuure boiler feed multistage water pump is a horizontal multistage centrifugal pump and suitable for transporting pure water,both ends of it are supported,the casing portion is a senctional form,it is connected and actuated by motor via a resilient clutch.From the driven direction,the pump rotated direction is clockwise.

 

2.Main Features of Multistage Centrifugal Water Pump for Portable Water

• High Effiency

•Low noise

Long life, OEM and ODM are welcomed.

3.Multistage Centrifugal Water Pump for Portable Water Images

High Pressure Boiler Feed Multistage Water Pump

4.Multistage Centrifugal Water Pump for Portable WaterSpecification

Material

 

Cast iron and as customer's request

Temperature

 

Less than 150°C

Flow rate

              3.75-300m3/h

Head

75-1000m

Medium temperature

0 ~170°C

Operation pressure

≤40 bars

5.FAQ

What is the applications

Power Station,Industry Water Supply

How to guarantee the quality of the products

We have established the international advanced quality management systemevery link from raw material to final product we have strict quality testWe resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance. Normally, We have 1 year warranty.

 

Q:What are the meanings of the vacuum pump, the front pump and the main pump?
The main pump and the front pump with the general vacuum unitThe front pump can be understood as a mechanical pump. It can be used by itself, but the pumping rate or the vacuum can not meet the requirements. In this case, we add a booster pump
Q:Metering pumps related matters
2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
Q:A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
Modify the part: (the design of regional common fire pump should be in accordance with the requirements of the original design, building design) contains a 55m high building, and the basement is about 6m, the pump reached in the basement height about 61m (common fire pump should be based on the highest floor of other low floor area, low ring and take in this case, relief measures) 61 levels, the most unfavorable hydrant to reach 0.07MPa (maximum allowable 0.5MPa) plus loss of lift at least about 90m more appropriate, of course can be higher to take relief measures (120 too high), the basic flow of lossless (with the same time there is only one building fire) according to the maximum amount of a building fire water pump set can be, there must be a backup with a preparation, and then select the appropriate pump manufacturer specification query.(the 20 houses on 99m are only shared with a 135m pump)
Q:How many millimeters is the diameter of the water outlet of the four inch pump?
If it is a centrifugal pump, the nominal diameter of the outlet is less than 4 inches, there is a conical short tube to enlarge the standard 4 inch outlet flange, from here, is the standard 4 inch flange connection.
Q:How many concrete pump tube diameter
Different pipe diameter is different, most of the 125, there are 150. Now we have the smallest pump on the market, with a pipe diameter of 100.
Q:Why does the centrifugal pump close the pressure to start?
The motor power is selected according to the rated flow of shaft power points plus 15 to 25%, if the outlet valve is fully open to start, the pump flow may deviate from the amount of fixed lot, pump efficiency also reduces a lot, resulting in shaft power greater than the motor power caused by tripping even burned electric machine.
Q:What is the pump lift voltage? And how to suppress the pumping voltage rise?
[suppression of pumping voltage] the general use of the installation of absorption resistance to absorb the pump voltage rise. The simplest way to control the pump voltage is to connect the DC bus with an energy consumption resistor before releasing the pump voltage.
Q:What is a solution pump?
Principle and structure features of canned motor pumpThe ordinary centrifugal pump is driven by coupling the pump impeller shaft is connected with the motor shaft, the impeller and the motor rotates while working and shielding pump is a kind of non seal pumps, pump and motor is sealed in a medium filled by pumping the pressure vessel, the pressure vessel only static seal and, by a group of wires to provide a rotating magnetic field and drive the rotor. This structure eliminated the traditional centrifugal pump with a rotary shaft sealing device, it can do no leakage.The pump and motor pump together, motor rotor and pump impeller fixed on the same shaft, use of shielding the rotor and the stator of the motor rotor separated in the medium, its power is transferred to the rotor through the stator magnetic field.
Q:Does the control cabinet of the fire control pump need to be related to the fire control room?
The relationship is simple, the fire pump is pressurized water supply device, the control cabinet is the power supply for the fire pump, the regulator tank is to stabilize the pressure of the network management, reduce the pump frequently start device.
Q:If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
What will happen then? The aquarium glass is an insulator. The water in the fish tank has the same potential as the live wire, and the fish is like a bird standing on the fire line. No electricity flows through their bodies, so they won't get electrocuted. But if you put your hands into the water, you will get an electric shock, because the line voltage through the water, then your body and the earth to form a loop, current flowing through your body you will get (of course, if you stand on the insulator does not get an electric shock)

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords